Array of potentiometric sensors for multicomponent analysis of blood serum

被引:7
|
作者
Correia, Daniela P. A. [1 ]
Magalhaes, Julia M. C. S. [1 ]
Machado, Adelio A. S. C. [1 ]
机构
[1] Univ Porto, Fac Ciencias, Dept Chem, LAQUIPAI, P-4169007 Oporto, Portugal
关键词
urea; potassium; carboxylated PVC; multicomponent analysis;
D O I
10.1007/s00604-007-0920-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two urea biosensors, based on carboxylated polyvinylchloride ammonium ion selective electrodes with urease immobilized with carbodiimide, were included in an array together with potassium and sodium ion selective electrodes and evaluated for simultaneous determination of urea and potassium in blood serum. The results show that it is possible to obtain principal component regression and partial least squares (PLS2) calibration models for simultaneous determination of urea (in the range 0.10-5 mM) and potassium (in the range 0.20-0.60 mM) based on a set of 9 calibration samples. The prediction errors of the concentration of urea and potassium in blood serum samples using this array and a PLS2 calibration model are lower than 13 and 5%, respectively.
引用
收藏
页码:131 / 137
页数:7
相关论文
共 50 条
  • [41] Array of potentiometric sensors for simultaneous determination of copper, silver, and cadmium ions in complex mixtures
    Shirmardi-Dezaki, Abbas
    Shamsipur, Mojtaba
    Akhond, Morteza
    Sharghi, Hashem
    Doroodmand, Mohammad Mandi
    ELECTROCHIMICA ACTA, 2012, 62 : 84 - 90
  • [42] Beer classification based on the array of solid-contact potentiometric sensors with thiacalixarene receptors
    Stoikova, E. E.
    Dolgova, N. N.
    Savel'ev, A. A.
    Galukhin, A. V.
    Stoikov, I. I.
    Antipin, I. S.
    Evtyugin, G. A.
    RUSSIAN CHEMICAL BULLETIN, 2014, 63 (01) : 223 - 231
  • [43] Potentiometric Sensor for Betahistine Determination in Pharmaceuticals, Urine and Blood Serum
    Ensafi, Ali A.
    Doozandeh, Fatemeh
    Allafchian, Ali R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2010, 21 (12) : 2246 - 2253
  • [44] DIRECT POTENTIOMETRIC DETERMINATION OF POTASSIUM AND SODIUM IN BLOOD, PLASMA, AND SERUM
    MIYADA, DS
    INAMI, K
    MATSUYAMA, G
    CLINICAL CHEMISTRY, 1971, 17 (01) : 27 - +
  • [45] Novel biomedical sensors for flow injection potentiometric determination of creatinine in human serum
    Hassan, SSM
    Elnemma, EM
    Mohamed, AHK
    ELECTROANALYSIS, 2005, 17 (24) : 2246 - 2253
  • [46] Multisensor system with an array of chemical sensors and artificial neural networks (electronic tongue) for quantitative analysis of multicomponent aqueous solutions
    Vlasov, YG
    Legin, AV
    Rudnitskaya, AM
    DiNatale, C
    DAmico, A
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1996, 69 (06) : 848 - 853
  • [47] Silicon-based chemical sensors for process analytical chemistry: design and development of an integrated sensor array for multicomponent analysis
    Carey, W.Patrick
    Process Control and Quality, 1993, 5 (2-3): : 137 - 144
  • [48] Chemical sensors and the development of potentiometric methods for analysis of liquid media
    Vlasov, YG
    Kolodnikov, VV
    Ermolenko, YE
    Mikhailova, SS
    JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 51 (08) : 741 - 752
  • [49] Integrated sensor array for analysis of multicomponent gas mixtures
    Anisimkin, VI
    Verona, E
    Zemlyakov, VE
    Kryshtal, RG
    Medved, AV
    TECHNICAL PHYSICS LETTERS, 1998, 24 (08) : 640 - 642
  • [50] Integrated sensor array for analysis of multicomponent gas mixtures
    V. I. Anisimkin
    É. Verona
    V. E. Zemlyakov
    R. G. Kryshtal’
    A. V. Medved’
    Technical Physics Letters, 1998, 24 : 640 - 642