Calibration update strategies for an array of potentiometric chemical sensors

被引:18
|
作者
Rudnitskaya, Alisa [1 ,2 ]
Costa, Ana Maria S. [2 ,3 ]
Delgadillo, Ivonne [2 ,3 ]
机构
[1] Univ Aveiro, CESAM, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Chem, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[3] Univ Aveiro, QOPNA, Campus Univ Santiago, P-3810193 Aveiro, Portugal
来源
关键词
Calibration update; Electronic tongue; Multivariate calibration standardization; Weighting; Tikhonov regularization; Joint-Y partial least square regression; MULTIVARIATE STANDARDIZATION; REGRESSION; MAINTENANCE; SELECTIVITY; VARIANTS; DESIGN;
D O I
10.1016/j.snb.2016.06.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the obstacles to the practical use of the multisensor systems - electronic tongues is a drift, i.e. gradual change of the sensor characteristics occurring in the process of their exploitation. Sensor drift leads to the deterioration of the performance of the calibration model that was calculated before changes in the sensor responses occurred. Two approaches can be employed to deal with this phenomenon. One consists of regular re-calibration of the sensor array, which is effective but time and labor consuming. Alternatively, multivariate statistical methods can be applied to the calibration model update using small subset of the standard samples. While significant efforts have been directed to the development of the calibration transfer and calibration update techniques, they were mostly applied to the near infrared spectroscopic instruments. Very few works addressed this issue for the potentiometric sensor arrays. In the present study, applicability of calibration update methods including slope and bias correction, direct standardization using PLS2 regression and auto-associative neural network, calibration update by weighting, Tikhonov regularization and Joint Y-PLS regression to the sensor array data was evaluated. Calibration models for copper and lead quantification in mixed solutions of transition metals using an array of 7 potentiometric sensors was used as an example. Of all studied methods, weighting and JYPLS regression were shown to be the most effective permitting to reduce prediction error for new data to the level of cross-validation error for the initial data. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1181 / 1189
页数:9
相关论文
共 50 条
  • [41] A CMOS Integrable DDCCII-Based Readout System For Portable Potentiometric Sensors Array
    Ferri, G.
    Stornelli, V.
    Di Carlo, C.
    De Marcellis, A.
    D'Amico, A.
    Di Natale, C.
    Martinelli, E.
    OLFACTION AND ELECTRONIC NOSE, PROCEEDINGS, 2009, 1137 : 310 - +
  • [42] Beer classification based on the array of solid-contact potentiometric sensors with thiacalixarene receptors
    E. E. Stoikova
    N. N. Dolgova
    A. A. Savel’ev
    A. V. Galukhin
    I. I. Stoikov
    I. S. Antipin
    G. A. Evtyugin
    Russian Chemical Bulletin, 2014, 63 : 223 - 231
  • [43] COMPARISON OF DIFFERENT CALIBRATION STRATEGIES FOR CONTINUOUS GLUCOSE MONITORING SENSORS
    Vettoretti, M.
    Facchinetti, A.
    Sparacino, G.
    Del Favero, S.
    Cobelli, C.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A16 - A16
  • [44] Calibration strategies for near-infrared glucose sensors.
    Small, GW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U42 - U42
  • [45] Array of potentiometric sensors for simultaneous determination of copper, silver, and cadmium ions in complex mixtures
    Shirmardi-Dezaki, Abbas
    Shamsipur, Mojtaba
    Akhond, Morteza
    Sharghi, Hashem
    Doroodmand, Mohammad Mandi
    ELECTROCHIMICA ACTA, 2012, 62 : 84 - 90
  • [46] Beer classification based on the array of solid-contact potentiometric sensors with thiacalixarene receptors
    Stoikova, E. E.
    Dolgova, N. N.
    Savel'ev, A. A.
    Galukhin, A. V.
    Stoikov, I. I.
    Antipin, I. S.
    Evtyugin, G. A.
    RUSSIAN CHEMICAL BULLETIN, 2014, 63 (01) : 223 - 231
  • [47] Strategies for achieving selectivity in chemical sensors.
    Helneman, WR
    Halsall, HB
    Seliskar, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U162 - U162
  • [48] COATING SELECTION-STRATEGIES FOR CHEMICAL SENSORS
    BALLANTINE, DS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 161 - ANYL
  • [49] Array calibration of angularly dependent gain and phase uncertainties with instrumental sensors
    Bu-Hong, W
    Yong-Liang, W
    Hui, C
    IEEE INTERNATIONAL SYMPOSIUM ON PHASED ARRAY SYSTEMS AND TECHNOLOGY 2003, 2003, : 182 - 186
  • [50] DoA Estimation and Sensors Self-Calibration for Partially Calibrated Array
    Dong, Fuwang
    Wang, Wei
    Wang, Ben
    GLOBAL OCEANS 2020: SINGAPORE - U.S. GULF COAST, 2020,