Calibration update strategies for an array of potentiometric chemical sensors

被引:18
|
作者
Rudnitskaya, Alisa [1 ,2 ]
Costa, Ana Maria S. [2 ,3 ]
Delgadillo, Ivonne [2 ,3 ]
机构
[1] Univ Aveiro, CESAM, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Chem, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[3] Univ Aveiro, QOPNA, Campus Univ Santiago, P-3810193 Aveiro, Portugal
来源
关键词
Calibration update; Electronic tongue; Multivariate calibration standardization; Weighting; Tikhonov regularization; Joint-Y partial least square regression; MULTIVARIATE STANDARDIZATION; REGRESSION; MAINTENANCE; SELECTIVITY; VARIANTS; DESIGN;
D O I
10.1016/j.snb.2016.06.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the obstacles to the practical use of the multisensor systems - electronic tongues is a drift, i.e. gradual change of the sensor characteristics occurring in the process of their exploitation. Sensor drift leads to the deterioration of the performance of the calibration model that was calculated before changes in the sensor responses occurred. Two approaches can be employed to deal with this phenomenon. One consists of regular re-calibration of the sensor array, which is effective but time and labor consuming. Alternatively, multivariate statistical methods can be applied to the calibration model update using small subset of the standard samples. While significant efforts have been directed to the development of the calibration transfer and calibration update techniques, they were mostly applied to the near infrared spectroscopic instruments. Very few works addressed this issue for the potentiometric sensor arrays. In the present study, applicability of calibration update methods including slope and bias correction, direct standardization using PLS2 regression and auto-associative neural network, calibration update by weighting, Tikhonov regularization and Joint Y-PLS regression to the sensor array data was evaluated. Calibration models for copper and lead quantification in mixed solutions of transition metals using an array of 7 potentiometric sensors was used as an example. Of all studied methods, weighting and JYPLS regression were shown to be the most effective permitting to reduce prediction error for new data to the level of cross-validation error for the initial data. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1181 / 1189
页数:9
相关论文
共 50 条
  • [31] IONIC TEMPERATURE SENSORS AND CALIBRATION SET FOR CHEMICAL LABORATORY
    ROSENKRANZ, J
    JAKES, D
    STRNAD, M
    KOTT, J
    CHEMICKE LISTY, 1985, 79 (05): : 549 - 553
  • [32] Redundant chemical sensors for calibration-impossible applications
    Seiter, JC
    DeGrandpre, MD
    TALANTA, 2001, 54 (01) : 99 - 106
  • [33] Potentiometric sensor array for the determination of lysine in feed samples using multivariate calibration methods
    N. García-Villar
    J. Saurina
    S. Hernández-Cassou
    Fresenius' Journal of Analytical Chemistry, 2001, 371 : 1001 - 1008
  • [34] Potentiometric sensor array for the determination of lysine in feed samples using multivariate calibration methods
    García-Villar, N
    Saurina, J
    Hernández-Cassou, S
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 371 (07): : 1001 - 1008
  • [35] IMMUNOCHEMICAL POTENTIOMETRIC SENSORS
    JANATA, J
    BLACKBURN, GF
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1984, 428 (JUN) : 286 - 292
  • [36] POTENTIOMETRIC ENZYMATIC SENSORS
    KONCKI, R
    GLAB, S
    CHEMIA ANALITYCZNA, 1991, 36 (03): : 423 - 446
  • [37] Immunoreactions in potentiometric sensors
    Kazimierczak, B
    Baraniecka, A
    Pijanowska, D
    Dawgul, M
    Kruk, J
    Krzysków, A
    Torbicz, W
    OPTICAL TECHNIQUES FOR ENVIRONMENTAL SENSING, WORKPLACE SAFETY, AND HEALTH MONITORING, 2002, 4887 : 137 - 140
  • [38] POTENTIOMETRIC ENZYME SENSORS
    VANDERSCHOOT, BH
    BERGVELD, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (4-5): : 335 - 335
  • [39] POTENTIOMETRIC GLUCOSE SENSORS
    HONOLD, F
    CAMMANN, K
    HORMONE AND METABOLIC RESEARCH, 1988, 20 : 47 - 49
  • [40] Potentiometric ion sensors
    Bobacka, Johan
    Ivaska, Ari
    Lewenstam, Andrzej
    CHEMICAL REVIEWS, 2008, 108 (02) : 329 - 351