Comparison of Different Automated Office Blood Pressure Measurement Devices: Evidence of Nonequivalence and Clinical Implications

被引:23
|
作者
Rinfret, Felix [1 ,2 ]
Cloutier, Lyne [3 ]
Wistaff, Robert [1 ]
Birnbaum, Leora M. [1 ]
Cheong, Nathalie Ng [1 ]
Laskine, Mikhael [1 ,4 ]
Roederer, Ghislaine [1 ]
Nguyen, Paul Van [1 ]
Bertrand, Michel [1 ]
Rabasa-Lhoret, Remi [1 ,5 ]
Dufour, Robert [1 ]
Lamarre-Cliche, Maxime [1 ]
机构
[1] IRCM, 110 Ave Pins Ouest, Montreal, PQ H2W 1R7, Canada
[2] Univ Montreal, Dept Sci Biomed, Montreal, PQ, Canada
[3] UQTR, Dept Sci Infirm, Trois Rivieres, PQ, Canada
[4] Univ Montreal, Ctr Rech, Ctr Hosp, Montreal, PQ, Canada
[5] Univ Montreal, Dept Nutr, Montreal, PQ, Canada
关键词
VALIDATION; MONITOR; TRIAL;
D O I
10.1016/j.cjca.2017.09.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Automated office blood pressure (AOBP) measuring devices are increasingly recommended as preferred blood pressure (BP) diagnostic tools, but it is unclear how they compare and how clinical environments impact their performance. Methods: This prospective randomized factorial parallel 4-group study compared BP estimates by BpTRU (VSM MedTech, Vancouver, BC, Canada) and Omron HEM 907 (Omron Healthcare, Kyoto, Japan) devices in closed vs open areas. Patients diagnosed with hypertension were recruited during office visits. After baseline open-room AOBP measurement with the BpTRU, patients had a second BP measurement with either the BpTRU or HEM 907 in either open or closed areas. Absolute BP levels and differences between the first and second measurements were compared. Diagnostic performance was also assessed. Results: Two hundred fifty-eight patients were studied. Their mean age was 66.2 +/- 12.0 years, and 62% were men. The mean of first AOBP estimates was 127.4/73.3 mm Hg. Analyses of subsequent measurements revealed no influence of open or closed areas on BP means and diagnostic performance. Conversely, the Omron HEM 907 exceeded BpTRU systolic BP measurements by 4.6 mm Hg (< 0.01) in closed areas and by 3.9 mm Hg (< 0.01) in open areas. The discrepancy between devices was amplified at lower BP levels. Conclusions: Although different areas did not influence BP estimates, the Omron HEM 907 significantly exceeded BpTRU measurements on average and especially at lower BP levels. These differences should be considered when interchanging devices and could have clinical decision impacts in a population of patients treated for hypertension. Our results support the constant use of only 1 device type in a given clinic.
引用
收藏
页码:1639 / 1644
页数:6
相关论文
共 50 条
  • [1] Comparison of routine and automated office blood pressure measurement
    Chen, Robin Z.
    Bhalla, Vivek
    Chang, Tara, I
    BLOOD PRESSURE MONITORING, 2019, 24 (04) : 174 - 178
  • [2] Unattended automated office blood pressure measurement - current evidence and the role in clinical practice
    Stopa, Marek
    Olszanecka, Agnieszka
    Rajzer, Marek
    ARTERIAL HYPERTENSION, 2021, 25 (03): : 100 - 105
  • [3] Automated office blood pressure measurement for routine clinical practice
    Myers, Martin G.
    Nelson, Mark R.
    Head, Geoffrey A.
    MEDICAL JOURNAL OF AUSTRALIA, 2012, 197 (07) : 372 - 373
  • [4] Automated Office Blood Pressure Measurement
    Myers, Martin G.
    KOREAN CIRCULATION JOURNAL, 2018, 48 (04) : 241 - 250
  • [5] Blood Pressure Variability The Implications of Home Versus Automated Office Measurement
    Rabkin, Simon W.
    HYPERTENSION, 2020, 75 (05) : 1161 - 1162
  • [6] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    BLOOD PRESSURE, 2022, 31 (01) : 9 - 18
  • [7] Comparison of Home and Office Blood Pressure Devices in the Clinical Setting
    Juraschek, Stephen P.
    Vyavahare, Medha
    Cluett, Jennifer L.
    Turkson-Ocran, Ruth-Alma
    Mukamal, Kenneth J.
    Ishak, Anthony M.
    AMERICAN JOURNAL OF HYPERTENSION, 2024, 37 (05) : 342 - 348
  • [9] The optimal use of automated office blood pressure measurement in clinical practice
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (04): : 555 - 559
  • [10] USE OF AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN ROUTINE CLINICAL PRACTICE
    Myers, M. G.
    Godwin, M.
    Dawes, M.
    Kiss, A.
    Tobe, S. W.
    Kaczorowski, J.
    JOURNAL OF HYPERTENSION, 2010, 28 : E14 - E15