Comparison of routine and automated office blood pressure measurement

被引:10
|
作者
Chen, Robin Z. [1 ]
Bhalla, Vivek [2 ]
Chang, Tara, I [2 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
[2] Stanford Univ, Div Nephrol, Palo Alto, CA 94304 USA
关键词
automated office blood pressure; blood pressure measurement; hypertension;
D O I
10.1097/MBP.0000000000000392
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives From April to October 2018, we implemented a blood pressure measurement quality improvement project at our Hypertension Center. We aimed to compare blood pressure measured using routine, non-standardized office blood pressure and Systolic Blood Pressure Intervention Trial-like automated office blood pressure protocols. Methods In 202 consecutive patients, we measured blood pressure using routine clinic methods and an automated office blood pressure protocol (5 min of rest followed by three blood pressure measurements at 1-min intervals). Results The mean routine blood pressure was 145.6/76.4 mmHg and the mean automated office blood pressure was 135.3/70.1 mmHg. The mean paired difference in blood pressure was 10.3/6.3 mmHg, and Bland-Altman plots demonstrated wide limits of agreement. Using the systolic blood pressure goal of 130 mmHg, 26.9% of the patients not at goal by routine blood pressure were at goal by automated office blood pressure. Conclusions Misclassifications of patient blood pressure control status and the wide variability between routine blood pressure and automated office blood pressure support the wider clinical implementation of automated office blood pressure to improve standardization, minimize incorrect blood pressure measurement and avoid over-treatment. Copyright (C) 2019 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 50 条
  • [1] Automated office blood pressure measurement for routine clinical practice
    Myers, Martin G.
    Nelson, Mark R.
    Head, Geoffrey A.
    MEDICAL JOURNAL OF AUSTRALIA, 2012, 197 (07) : 372 - 373
  • [2] USE OF AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN ROUTINE CLINICAL PRACTICE
    Myers, M. G.
    Godwin, M.
    Dawes, M.
    Kiss, A.
    Tobe, S. W.
    Kaczorowski, J.
    JOURNAL OF HYPERTENSION, 2010, 28 : E14 - E15
  • [3] Automated Office Blood Pressure Measurement
    Myers, Martin G.
    KOREAN CIRCULATION JOURNAL, 2018, 48 (04) : 241 - 250
  • [4] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    BLOOD PRESSURE, 2022, 31 (01) : 9 - 18
  • [5] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT VERSUS CLASSIC OFFICE AUTOMATED BLOOD PRESSURE MEASUREMENT IN A HYPERTENSION OUTPATIENT CLINIC
    Legrady, Peter
    Fejes, Imola
    Czombos, Andras
    Abraham, Gyorgy
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E99 - E99
  • [6] Comparison of routine office blood pressure measurement versus standardized attended manually activated oscillometric office blood pressure measurement in patients with chronic kidney disease
    Chellappan, Anand
    Kansal, Keshiha
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2024, 13 (05) : 1894 - 1903
  • [7] Unattended automated office blood pressure measurement in children
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    BLOOD PRESSURE, 2021, 30 (06) : 359 - 366
  • [9] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    PEDIATRIC NEPHROLOGY, 2022, 37 (11) : 2812 - 2812
  • [10] The Fallacy of Attended Automated Office Blood Pressure Measurement
    Myers, Martin G.
    AMERICAN JOURNAL OF HYPERTENSION, 2018, 31 (07) : 755 - 757