Comparison of Different Automated Office Blood Pressure Measurement Devices: Evidence of Nonequivalence and Clinical Implications

被引:23
|
作者
Rinfret, Felix [1 ,2 ]
Cloutier, Lyne [3 ]
Wistaff, Robert [1 ]
Birnbaum, Leora M. [1 ]
Cheong, Nathalie Ng [1 ]
Laskine, Mikhael [1 ,4 ]
Roederer, Ghislaine [1 ]
Nguyen, Paul Van [1 ]
Bertrand, Michel [1 ]
Rabasa-Lhoret, Remi [1 ,5 ]
Dufour, Robert [1 ]
Lamarre-Cliche, Maxime [1 ]
机构
[1] IRCM, 110 Ave Pins Ouest, Montreal, PQ H2W 1R7, Canada
[2] Univ Montreal, Dept Sci Biomed, Montreal, PQ, Canada
[3] UQTR, Dept Sci Infirm, Trois Rivieres, PQ, Canada
[4] Univ Montreal, Ctr Rech, Ctr Hosp, Montreal, PQ, Canada
[5] Univ Montreal, Dept Nutr, Montreal, PQ, Canada
关键词
VALIDATION; MONITOR; TRIAL;
D O I
10.1016/j.cjca.2017.09.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Automated office blood pressure (AOBP) measuring devices are increasingly recommended as preferred blood pressure (BP) diagnostic tools, but it is unclear how they compare and how clinical environments impact their performance. Methods: This prospective randomized factorial parallel 4-group study compared BP estimates by BpTRU (VSM MedTech, Vancouver, BC, Canada) and Omron HEM 907 (Omron Healthcare, Kyoto, Japan) devices in closed vs open areas. Patients diagnosed with hypertension were recruited during office visits. After baseline open-room AOBP measurement with the BpTRU, patients had a second BP measurement with either the BpTRU or HEM 907 in either open or closed areas. Absolute BP levels and differences between the first and second measurements were compared. Diagnostic performance was also assessed. Results: Two hundred fifty-eight patients were studied. Their mean age was 66.2 +/- 12.0 years, and 62% were men. The mean of first AOBP estimates was 127.4/73.3 mm Hg. Analyses of subsequent measurements revealed no influence of open or closed areas on BP means and diagnostic performance. Conversely, the Omron HEM 907 exceeded BpTRU systolic BP measurements by 4.6 mm Hg (< 0.01) in closed areas and by 3.9 mm Hg (< 0.01) in open areas. The discrepancy between devices was amplified at lower BP levels. Conclusions: Although different areas did not influence BP estimates, the Omron HEM 907 significantly exceeded BpTRU measurements on average and especially at lower BP levels. These differences should be considered when interchanging devices and could have clinical decision impacts in a population of patients treated for hypertension. Our results support the constant use of only 1 device type in a given clinic.
引用
收藏
页码:1639 / 1644
页数:6
相关论文
共 50 条
  • [31] Fully Automated Blood Pressure Measurement Is the Way to Go in the Office
    Shaughnessy, Allen F.
    AMERICAN FAMILY PHYSICIAN, 2019, 100 (10) : 646 - 646
  • [32] Comparison of home blood pressure and office blood pressure measurement in dogs and cats
    Koo, Siu To
    Carr, Anthony P.
    CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE, 2022, 86 (03): : 203 - 208
  • [33] Automated Office Blood Pressure
    Myers, Martin G.
    Godwin, Marshall
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (03) : 341 - 346
  • [34] IN THE AFTERMATH OF SPRINT: FURTHER COMPARISON OF UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT AND 24-HOUR BLOOD PRESSURE MONITORING
    Seidlerova, J. Mlikova
    Gelzinsky, J.
    Materankova, M.
    Ceral, J.
    Filipovsky, J.
    JOURNAL OF HYPERTENSION, 2019, 37 : E193 - E193
  • [35] In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring
    Seidlerova, Jitka
    Gelzinsky, Julius
    Materankova, Marketa
    Ceral, Jiri
    Konig, Petr
    Filipovsky, Jan
    BLOOD PRESSURE, 2018, 27 (05) : 256 - 261
  • [36] BLOOD PRESSURE MEASUREMENT IN CHILDREN AND ADOLESCENTS: A COMPARISON OF OFFICE, AMBULATORY AND HOME BLOOD PRESSURE MEASUREMENT
    Salgado, C. M.
    Viana, J. K. B.
    Jardim, P. C. B. V.
    Jardim, T. S. V.
    Souza, W. K. S. B.
    Souza, A. L. L.
    Ribeiro, L. M.
    Carvalho, M. C.
    Pereira, D. A.
    JOURNAL OF HYPERTENSION, 2009, 27 : S196 - S196
  • [37] Comparison of Office Blood Pressure, Automated Unattended Office Blood Pressure, Home Blood Pressure, and 24-Hour Ambulatory Blood Pressure Measurements
    Kim, Byung Jin
    Lee, Sung Ho
    Lee, Mi Yeon
    Lee, Seung Jae
    Choi, Hyo In
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (48)
  • [38] Office blood pressure measurements with oscillometric devices in adolescents: a comparison with home blood pressure
    Jardim, Thiago Veiga
    Gaziano, Thomas A.
    Nascente, Flavia Miquetichuc
    Carneiro, Carolina de Souza
    Morais, Polyana
    Roriz, Vanessa
    Mendonca, Karla Lorena
    Rolim Povoa, Thais Inacio
    Sebba Barroso, Weimar Kunz
    Lima Sousa, Ana Luiza
    Veiga Jardim, Paulo Cesar
    BLOOD PRESSURE, 2017, 26 (05) : 272 - 278
  • [39] The clinical value of automated office blood pressure: What is the latest evidence on attended vs unattended automated readings in clinical practice?
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    Papademetriou, Vasilios
    JOURNAL OF CLINICAL HYPERTENSION, 2019, 21 (02): : 156 - 158
  • [40] Comparison of different measures of blood pressure - Blood pressure measurement causes problems in clinical practice
    Marshall, T