In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring

被引:11
|
作者
Seidlerova, Jitka [1 ,2 ]
Gelzinsky, Julius [1 ]
Materankova, Marketa [1 ]
Ceral, Jiri [3 ]
Konig, Petr [1 ]
Filipovsky, Jan [1 ,2 ]
机构
[1] Charles Univ Prague, Fac Med Pilsen, Internal Dept 2, Hradec Kralove, Czech Republic
[2] Charles Univ Prague, Fac Med Pilsen, Biomed Ctr, Hradec Kralove, Czech Republic
[3] Fac Hosp Hradec Kralove, Dept Cardiol, Hradec Kralove, Czech Republic
关键词
Unattended automated blood pressure; ambulatory blood pressure monitoring; attended office blood pressure; BPTru device; blood pressure measurement; blood pressure variability; white-coat effect; HYPERTENSION; VARIABILITY; MANAGEMENT; TRIAL;
D O I
10.1080/08037051.2018.1454258
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aims: Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability.Material and methods: Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit.Results: Data on 98 subjects aged 67.79.3 years with 24-hour ABPM 120.3 +/- 10.6/72.7 +/- 7.9mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 +/- 11.3/-0.5 +/- 6.9mm Hg) and daytime (by -6.7 +/- 12.82.4 +/- 8.0mm Hg) ABPM and the individual variability of the difference was very large (up to 30mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p.17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 +/- 7.0 vs. 2.2 +/- 10.3mm Hg; p=.0036).Conclusions: Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.
引用
收藏
页码:256 / 261
页数:6
相关论文
共 50 条
  • [1] IN THE AFTERMATH OF SPRINT: FURTHER COMPARISON OF UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT AND 24-HOUR BLOOD PRESSURE MONITORING
    Seidlerova, J. Mlikova
    Gelzinsky, J.
    Materankova, M.
    Ceral, J.
    Filipovsky, J.
    [J]. JOURNAL OF HYPERTENSION, 2019, 37 : E193 - E193
  • [2] Comparison of Office Blood Pressure, Automated Unattended Office Blood Pressure, Home Blood Pressure, and 24-Hour Ambulatory Blood Pressure Measurements
    Kim, Byung Jin
    Lee, Sung Ho
    Lee, Mi Yeon
    Lee, Seung Jae
    Choi, Hyo In
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (48)
  • [3] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    [J]. BLOOD PRESSURE, 2022, 31 (01) : 9 - 18
  • [4] THE VALUE OF ATTENDED AND UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE (AOBP) IN CLINICAL PRACTICE: COMPARISON WITH CONVENTIONAL OFFICE BLOOD PRESSURE (OBP) MEASUREMENTS AND 24-HOUR
    Andreadis, E.
    Geladari, C.
    Savva, F.
    Angelopoulos, E.
    Georgantoni, A.
    Apeiranthiti, K.
    Pantikidi, E.
    Papademetriou, V.
    [J]. JOURNAL OF HYPERTENSION, 2018, 36 : E218 - E218
  • [5] Comparability of Automated Office Blood Pressure to Daytime 24-Hour Ambulatory Blood Pressure
    Ringrose, Jennifer S.
    Cena, Jonathan
    Ip, Shannon
    Morales, Fraulein
    Hamilton, Peter
    Padwal, Raj
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2018, 34 (01) : 61 - 65
  • [6] Multiple office blood pressure measurement is not inferior to home blood pressure monitoring compared with 24-hour ambulatory blood pressure monitoring: a prospective multicenter study
    Choi, T. Y.
    Rhee, M. Y.
    Park, H. B.
    Kim, J. H.
    Namgung, J.
    Lee, S. Y.
    Cho, D. K.
    Kim, S. Y.
    Kim, J. Y.
    Park, J. S.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 : 674 - 675
  • [7] Unattended automated office blood pressure measurement in children
    Seeman, Tomas
    [J]. BLOOD PRESSURE, 2023, 32 (01)
  • [8] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    [J]. PEDIATRIC NEPHROLOGY, 2022, 37 (11) : 2812 - 2812
  • [9] Automated office blood pressure is in agreement with awake and mean 24-hour ambulatory blood pressure at the lower blood pressure range
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (07): : 1177 - 1183
  • [10] Unattended automated office blood pressure measurement in children
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    [J]. BLOOD PRESSURE, 2021, 30 (06) : 359 - 366