Comparison of Different Automated Office Blood Pressure Measurement Devices: Evidence of Nonequivalence and Clinical Implications

被引:23
|
作者
Rinfret, Felix [1 ,2 ]
Cloutier, Lyne [3 ]
Wistaff, Robert [1 ]
Birnbaum, Leora M. [1 ]
Cheong, Nathalie Ng [1 ]
Laskine, Mikhael [1 ,4 ]
Roederer, Ghislaine [1 ]
Nguyen, Paul Van [1 ]
Bertrand, Michel [1 ]
Rabasa-Lhoret, Remi [1 ,5 ]
Dufour, Robert [1 ]
Lamarre-Cliche, Maxime [1 ]
机构
[1] IRCM, 110 Ave Pins Ouest, Montreal, PQ H2W 1R7, Canada
[2] Univ Montreal, Dept Sci Biomed, Montreal, PQ, Canada
[3] UQTR, Dept Sci Infirm, Trois Rivieres, PQ, Canada
[4] Univ Montreal, Ctr Rech, Ctr Hosp, Montreal, PQ, Canada
[5] Univ Montreal, Dept Nutr, Montreal, PQ, Canada
关键词
VALIDATION; MONITOR; TRIAL;
D O I
10.1016/j.cjca.2017.09.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Automated office blood pressure (AOBP) measuring devices are increasingly recommended as preferred blood pressure (BP) diagnostic tools, but it is unclear how they compare and how clinical environments impact their performance. Methods: This prospective randomized factorial parallel 4-group study compared BP estimates by BpTRU (VSM MedTech, Vancouver, BC, Canada) and Omron HEM 907 (Omron Healthcare, Kyoto, Japan) devices in closed vs open areas. Patients diagnosed with hypertension were recruited during office visits. After baseline open-room AOBP measurement with the BpTRU, patients had a second BP measurement with either the BpTRU or HEM 907 in either open or closed areas. Absolute BP levels and differences between the first and second measurements were compared. Diagnostic performance was also assessed. Results: Two hundred fifty-eight patients were studied. Their mean age was 66.2 +/- 12.0 years, and 62% were men. The mean of first AOBP estimates was 127.4/73.3 mm Hg. Analyses of subsequent measurements revealed no influence of open or closed areas on BP means and diagnostic performance. Conversely, the Omron HEM 907 exceeded BpTRU systolic BP measurements by 4.6 mm Hg (< 0.01) in closed areas and by 3.9 mm Hg (< 0.01) in open areas. The discrepancy between devices was amplified at lower BP levels. Conclusions: Although different areas did not influence BP estimates, the Omron HEM 907 significantly exceeded BpTRU measurements on average and especially at lower BP levels. These differences should be considered when interchanging devices and could have clinical decision impacts in a population of patients treated for hypertension. Our results support the constant use of only 1 device type in a given clinic.
引用
收藏
页码:1639 / 1644
页数:6
相关论文
共 50 条
  • [21] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    PEDIATRIC NEPHROLOGY, 2022, 37 (11) : 2812 - 2812
  • [22] The Fallacy of Attended Automated Office Blood Pressure Measurement
    Myers, Martin G.
    AMERICAN JOURNAL OF HYPERTENSION, 2018, 31 (07) : 755 - 757
  • [23] Automated Office Blood Pressure Measurement for the Diagnosis of Hypertension
    Filler, Guido
    de Ferris, Maria E. Diaz-Gonzalez
    JOURNAL OF PEDIATRICS, 2020, 227 : 10 - 12
  • [24] Automated office blood pressure measurement in primary care
    Myers, Martin G.
    Kaczorowski, Janusz
    Dawes, Martin
    Godwin, Marshall
    CANADIAN FAMILY PHYSICIAN, 2014, 60 (02) : 127 - 132
  • [25] Office blood pressure measurement types: Different methodology-Different clinical conclusions
    Stergiou, George S.
    Kyriakoulis, Konstantinos G.
    Kollias, Anastasios
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (12): : 1683 - 1685
  • [26] Repeated office blood pressure measurement by automated device to evaluate blood pressure control
    Crippa, G
    Sverzellati, E
    Venturi, C
    Antoniotti, P
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 46A - 46A
  • [27] COMPARISON OF AUTOMATED OFFICE BLOOD PRESSURE WITH OFFICE AND OUT-OF-OFFICE MEASUREMENT TECHNIQUES: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Pappaccogli, M.
    Di Monaco, S.
    Perlo, E.
    Burrello, J.
    D'Ascenzo, F.
    Veglio, F.
    Monticone, S.
    Rabbia, F.
    JOURNAL OF HYPERTENSION, 2019, 37 : E300 - E300
  • [28] Determination of normal values for automated measurement of blood pressure in the office
    Myers, M. G.
    Valdivieso, M.
    Kiss, A.
    JOURNAL OF HYPERTENSION, 2008, 26 : S485 - S485
  • [29] Automated Office Blood Pressure Measurement Requires Technology and Implementation
    Boonyasai, Romsai Tony
    JAMA NETWORK OPEN, 2022, 5 (08) : E2232775
  • [30] MINIMUM NUMBER OF READINGS FOR AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT
    Myers, M. G.
    Dawes, M.
    Godwin, M.
    Kaczorowski, J.
    Kiss, A.
    Tobe, S. W.
    JOURNAL OF HYPERTENSION, 2009, 27 : S197 - S197