Is maximum isometric muscle stress the same among prime elbow flexors?

被引:15
|
作者
Li, Le
Tong, Kaiyu [1 ]
Song, Rong
Koo, Terry K. K.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] New York Chiropract Coll, Dept Res, Foot Levelers Biomech Res Lab, Seneca Falls, NY 13148 USA
关键词
elbow; maximum isometric muscle stress; musculotendon parameters; musculoskeletal model; ultrasonography;
D O I
10.1016/j.clinbiomech.2007.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Previous musculoskeletal modeling studies have adopted the assumption of the same maximum isometric muscle stress among the prime elbow flexors. This study aimed at estimating the maximum isometric muscle stress based on subject-specific modeling parameters measured in vivo and validating that assumption. Methods. Subject-specific musculoskeletal models of the upper limbs of five normal subjects were developed, which incorporated anthropometrically scaled graphics-based geometrical models and Hill-type musculotendon models of the prime elbow flexors. B-mode ultrasound technique was employed to measure the muscle optimal length and pennation angle of each prime elbow flexor, and these architectural parameters were inputted into the model to reduce the number of unknown parameters to be optimized. To allow changes of individual maximum isometric muscle force of the prime elbow flexors, optimizations were conducted by minimizing the root mean square difference between the predicted and measured isometric torque-angle curves. Maximum isometric muscle stress of each prime elbow flexor was estimated by dividing the maximum isometric muscle force with the corresponding physiological cross-sectional area. Findings. Our findings showed that maximum isometric muscle stress among the prime elbow flexors was not significantly different from each other. Thus it appears that it is reasonable to assume the same value for maximum isometric muscle stress for all prime elbow flexors in musculoskeletal modeling studies. Interpretation. Latest medical imaging techniques such as ultrasound for the estimation of musculotendon parameters would provide an alterative method to obtain the muscle architecture parameters noninvasively. The subject-specific musculotendon parameters estimated in this study could be used for developing the neuromusculoskeletal model to predict muscle force and evaluate muscle functions. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [41] Changes in the angle-force curve of human elbow flexors following eccentric and isometric exercise
    Anastassios Philippou
    Gregory C. Bogdanis
    Alan M. Nevill
    Maria Maridaki
    European Journal of Applied Physiology, 2004, 93 : 237 - 244
  • [42] Circadian rhythm in the torque developed by elbow flexors during isometric contraction, effect of sampling schedules
    Gauthier, A
    Davenne, D
    Gentil, C
    VanHoecke, J
    CHRONOBIOLOGY INTERNATIONAL, 1997, 14 (03) : 287 - 294
  • [43] In Vivo Measurements of Moment Arm Lengths of Three Elbow Flexors at Rest and During Isometric Contractions
    Akagi, Ryota
    Iwanuma, Soichiro
    Hashizume, Satoru
    Kanehisa, Hiroaki
    Yanai, Toshimasa
    Kawakami, Yasuo
    JOURNAL OF APPLIED BIOMECHANICS, 2012, 28 (01) : 63 - 69
  • [44] CHANGES IN STRENGTH AND CROSS-SECTIONAL AREA OF THE ELBOW FLEXORS AS A RESULT OF ISOMETRIC STRENGTH TRAINING
    DAVIES, J
    PARKER, DF
    RUTHERFORD, OM
    JONES, DA
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1988, 57 (06): : 667 - 670
  • [45] Effects Of Repeated Bout Of Eccentric Exercise On Muscle Stiffness In Elbow Flexors
    Sun, Min-Ghyu
    Kim, Choun-Sub
    Kim, Maeng-Kyu
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 930 - 930
  • [46] EIGHT-WEEK VIBRATION TRAINING OF THE ELBOW FLEXORS BY FORCE MODULATION: EFFECTS ON DYNAMIC AND ISOMETRIC STRENGTH
    Xu, Lin
    Cardinale, Marco
    Rabotti, Chiara
    Beju, Bogdan
    Mischi, Massimo
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (03) : 739 - 746
  • [47] Assessment of eccentric exercise-induced muscle damage of the elbow flexors by tensiomyography
    Hunter, Angus M.
    Galloway, Stuart D. R.
    Smith, Iain J.
    Tallent, Jamie
    Ditroilo, Massimiliano
    Fairweather, Malcolm M.
    Howatson, Glyn
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2012, 22 (03) : 334 - 341
  • [48] The Validity and Reliability of a Sphygmomanometer in Assessing Isometric Muscle Strength of Shoulder Flexors and Abductors
    Ilyas, Arzish
    Ahmad, Ashfaq
    Gillani, Syed Amir
    Bukhari, Bazal
    Gillani, Humna
    ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2019, 25 (04):
  • [49] SKELETAL-MUSCLE STIFFNESS AND PAIN FOLLOWING ECCENTRIC EXERCISE OF THE ELBOW FLEXORS
    JONES, DA
    NEWHAM, DJ
    CLARKSON, PM
    PAIN, 1987, 30 (02) : 233 - 242
  • [50] Negative and positive stiffness of elbow flexors with constant muscle activation in isovelocity movements
    Akazawa, K
    Okuno, R
    ELECTROPHYSIOLOGY AND KINESIOLOGY, 2000, : 231 - 235