Is maximum isometric muscle stress the same among prime elbow flexors?

被引:15
|
作者
Li, Le
Tong, Kaiyu [1 ]
Song, Rong
Koo, Terry K. K.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] New York Chiropract Coll, Dept Res, Foot Levelers Biomech Res Lab, Seneca Falls, NY 13148 USA
关键词
elbow; maximum isometric muscle stress; musculotendon parameters; musculoskeletal model; ultrasonography;
D O I
10.1016/j.clinbiomech.2007.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Previous musculoskeletal modeling studies have adopted the assumption of the same maximum isometric muscle stress among the prime elbow flexors. This study aimed at estimating the maximum isometric muscle stress based on subject-specific modeling parameters measured in vivo and validating that assumption. Methods. Subject-specific musculoskeletal models of the upper limbs of five normal subjects were developed, which incorporated anthropometrically scaled graphics-based geometrical models and Hill-type musculotendon models of the prime elbow flexors. B-mode ultrasound technique was employed to measure the muscle optimal length and pennation angle of each prime elbow flexor, and these architectural parameters were inputted into the model to reduce the number of unknown parameters to be optimized. To allow changes of individual maximum isometric muscle force of the prime elbow flexors, optimizations were conducted by minimizing the root mean square difference between the predicted and measured isometric torque-angle curves. Maximum isometric muscle stress of each prime elbow flexor was estimated by dividing the maximum isometric muscle force with the corresponding physiological cross-sectional area. Findings. Our findings showed that maximum isometric muscle stress among the prime elbow flexors was not significantly different from each other. Thus it appears that it is reasonable to assume the same value for maximum isometric muscle stress for all prime elbow flexors in musculoskeletal modeling studies. Interpretation. Latest medical imaging techniques such as ultrasound for the estimation of musculotendon parameters would provide an alterative method to obtain the muscle architecture parameters noninvasively. The subject-specific musculotendon parameters estimated in this study could be used for developing the neuromusculoskeletal model to predict muscle force and evaluate muscle functions. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [21] Measurements of Isometric Strength and Electromyography of Elbow Flexors under Active and Passive Conditions
    Higa, Masaru
    Araki, Nozomu
    Nakatani, Shintaro
    Toji, Hideki
    ADVANCED BIOMEDICAL ENGINEERING, 2019, 8 : 124 - 129
  • [22] Does the Length of Elbow Flexors and Visual Feedback Have Effect on Accuracy of Isometric Muscle Contraction in Men after Stroke?
    Juodzbaliene, Vilma
    Darbutas, Tomas
    Skurvydas, Albertas
    Brazaitis, Marius
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [23] INTRASESSION AND INTERSESSION RELIABILITY IN MAXIMAL AND EXPLOSIVE ISOMETRIC TORQUE PRODUCTION OF THE ELBOW FLEXORS
    Prieske, Olaf
    Wick, Ditmar
    Granacher, Urs
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (06) : 1771 - 1777
  • [24] Isometric torque-angle relationships of the elbow flexors and extensors in the transverse plane
    Pinter, Ilona J.
    Bobbert, Maarten F.
    van Soest, A. J. Knoek
    Smeets, Jeroen B. J.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2010, 20 (05) : 923 - 931
  • [25] Changes in fluctuation of isometric force following eccentric and concentric exercise of the elbow flexors
    Andrew P. Lavender
    Kazunori Nosaka
    European Journal of Applied Physiology, 2006, 96 : 235 - 240
  • [26] Effects of Isometric Contraction on Stress Relaxation of the Plantar Flexors
    Stewart, Andrew M.
    Jacobs, Ilze R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 635 - 636
  • [27] RELATIONSHIP BETWEEN MAXIMUM ISOMETRIC TENSION AND BREAKING STRENGTH OF FOREARM FLEXORS
    RASCH, PJ
    PIERSON, WR
    RESEARCH QUARTERLY, 1960, 31 (03): : 534 - 535
  • [28] RELATIONSHIP BETWEEN MAXIMUM ISOMETRIC TENSION AND MAXIMUM ISOTONIC ELBOW FLEXION
    RASCH, PJ
    RESEARCH QUARTERLY, 1957, 28 (01): : 85 - 85
  • [29] Syncoilin is required for generating maximum isometric stress in skeletal muscle but dispensable for muscle cytoarchitecture
    Zhang, Jianlin
    Bang, Marie-Louise
    Gokhin, David S.
    Lu, Yingchun
    Cui, Li
    Li, Xiaodong
    Gu, Yusu
    Dalton, Nancy D.
    Scimia, Maria Cecilia
    Peterson, Kirk L.
    Lieber, Richard L.
    Chen, Ju
    AMERICAN JOURNAL OF PHYSIOLOGY-CELL PHYSIOLOGY, 2008, 294 (05): : C1175 - C1182
  • [30] Does Performance-Related Information Augment the Maximal Isometric Force in the Elbow Flexors?
    William Miller
    Sunggun Jeon
    Minsoo Kang
    Jun Seob Song
    Xin Ye
    Applied Psychophysiology and Biofeedback, 2021, 46 : 91 - 101