Is maximum isometric muscle stress the same among prime elbow flexors?

被引:15
|
作者
Li, Le
Tong, Kaiyu [1 ]
Song, Rong
Koo, Terry K. K.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] New York Chiropract Coll, Dept Res, Foot Levelers Biomech Res Lab, Seneca Falls, NY 13148 USA
关键词
elbow; maximum isometric muscle stress; musculotendon parameters; musculoskeletal model; ultrasonography;
D O I
10.1016/j.clinbiomech.2007.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Previous musculoskeletal modeling studies have adopted the assumption of the same maximum isometric muscle stress among the prime elbow flexors. This study aimed at estimating the maximum isometric muscle stress based on subject-specific modeling parameters measured in vivo and validating that assumption. Methods. Subject-specific musculoskeletal models of the upper limbs of five normal subjects were developed, which incorporated anthropometrically scaled graphics-based geometrical models and Hill-type musculotendon models of the prime elbow flexors. B-mode ultrasound technique was employed to measure the muscle optimal length and pennation angle of each prime elbow flexor, and these architectural parameters were inputted into the model to reduce the number of unknown parameters to be optimized. To allow changes of individual maximum isometric muscle force of the prime elbow flexors, optimizations were conducted by minimizing the root mean square difference between the predicted and measured isometric torque-angle curves. Maximum isometric muscle stress of each prime elbow flexor was estimated by dividing the maximum isometric muscle force with the corresponding physiological cross-sectional area. Findings. Our findings showed that maximum isometric muscle stress among the prime elbow flexors was not significantly different from each other. Thus it appears that it is reasonable to assume the same value for maximum isometric muscle stress for all prime elbow flexors in musculoskeletal modeling studies. Interpretation. Latest medical imaging techniques such as ultrasound for the estimation of musculotendon parameters would provide an alterative method to obtain the muscle architecture parameters noninvasively. The subject-specific musculotendon parameters estimated in this study could be used for developing the neuromusculoskeletal model to predict muscle force and evaluate muscle functions. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [31] THE PRESSOR-RESPONSE TO ISOMETRIC-EXERCISE OF THE ELBOW FLEXORS IN YOUNG AND ELDERLY MEN
    CARRINGTON, CA
    WHITE, MJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1992, 446 : P212 - P212
  • [32] Does Performance-Related Information Augment the Maximal Isometric Force in the Elbow Flexors?
    Miller, William
    Jeon, Sunggun
    Kang, Minsoo
    Song, Jun Seob
    Ye, Xin
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2021, 46 (01) : 91 - 101
  • [33] Acute Effects of Caffeine on Strength and Muscle Activation of the Elbow Flexors
    Trevino, Michael A.
    Coburn, Jared W.
    Brown, Lee E.
    Judelson, Daniel A.
    Malek, Moh H.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 639 - 639
  • [34] Acute Effects of Caffeine on Strength and Muscle Activation of the Elbow Flexors
    Trevino, Michael A.
    Coburn, Jared W.
    Brown, Lee E.
    Judelson, Daniel A.
    Malek, Moh H.
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2012, 27 : 639 - 639
  • [35] ACUTE EFFECTS OF CAFFEINE ON STRENGTH AND MUSCLE ACTIVATION OF THE ELBOW FLEXORS
    Trevino, Michael A.
    Coburn, Jared W.
    Brown, Lee E.
    Judelson, Daniel A.
    Malek, Moh H.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (02) : 513 - 520
  • [36] Effect of lengthening contraction velocity on muscle damage of the elbow flexors
    Chapman, Dale Wilson
    Newton, Michael
    Mcguigan, Michael
    Nosaka, Kazunori
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : 926 - 933
  • [37] Muscle damage and soreness after endurance exercise of the elbow flexors
    Nosaka, K
    Newton, M
    Sacco, P
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (06): : 920 - 927
  • [38] Comparison of maximal muscle strength of elbow flexors and knee extensors between younger and older men with the same level of daily activity
    Damas Nogueira, Felipe Romano
    Libardi, Cleiton Augusto
    Vechin, Felipe Cassaro
    Lixandrao, Manoel Emilio
    de Barros Berton, Ricardo Paes
    Frota de Souza, Thiago Mattos
    Conceicao, Miguel Soares
    Cavaglieri, Claudia Regina
    Traina Chacon-Mikahil, Mara Patricia
    CLINICAL INTERVENTIONS IN AGING, 2013, 8 : 401 - 407
  • [40] Changes in the angle-force curve of human elbow flexors following eccentric and isometric exercise
    Philippou, A
    Bogdanis, GC
    Nevill, AM
    Maridaki, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 93 (1-2) : 237 - 244