Is maximum isometric muscle stress the same among prime elbow flexors?

被引:15
|
作者
Li, Le
Tong, Kaiyu [1 ]
Song, Rong
Koo, Terry K. K.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] New York Chiropract Coll, Dept Res, Foot Levelers Biomech Res Lab, Seneca Falls, NY 13148 USA
关键词
elbow; maximum isometric muscle stress; musculotendon parameters; musculoskeletal model; ultrasonography;
D O I
10.1016/j.clinbiomech.2007.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Previous musculoskeletal modeling studies have adopted the assumption of the same maximum isometric muscle stress among the prime elbow flexors. This study aimed at estimating the maximum isometric muscle stress based on subject-specific modeling parameters measured in vivo and validating that assumption. Methods. Subject-specific musculoskeletal models of the upper limbs of five normal subjects were developed, which incorporated anthropometrically scaled graphics-based geometrical models and Hill-type musculotendon models of the prime elbow flexors. B-mode ultrasound technique was employed to measure the muscle optimal length and pennation angle of each prime elbow flexor, and these architectural parameters were inputted into the model to reduce the number of unknown parameters to be optimized. To allow changes of individual maximum isometric muscle force of the prime elbow flexors, optimizations were conducted by minimizing the root mean square difference between the predicted and measured isometric torque-angle curves. Maximum isometric muscle stress of each prime elbow flexor was estimated by dividing the maximum isometric muscle force with the corresponding physiological cross-sectional area. Findings. Our findings showed that maximum isometric muscle stress among the prime elbow flexors was not significantly different from each other. Thus it appears that it is reasonable to assume the same value for maximum isometric muscle stress for all prime elbow flexors in musculoskeletal modeling studies. Interpretation. Latest medical imaging techniques such as ultrasound for the estimation of musculotendon parameters would provide an alterative method to obtain the muscle architecture parameters noninvasively. The subject-specific musculotendon parameters estimated in this study could be used for developing the neuromusculoskeletal model to predict muscle force and evaluate muscle functions. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [11] Effect of two maximal isometric contractions on eccentric exercise-induced muscle damage of the elbow flexors
    Chen, Trevor C.
    Chen, Hsin-Lian
    Lin, Ming-Ju
    Chen, Che-Hsiu
    Pearce, Alan J.
    Nosaka, Kazunori
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2013, 113 (06) : 1545 - 1554
  • [12] Unilateral isometric muscle fatigue decreases force production and activation of contralateral knee extensors but not elbow flexors
    Halperin, Israel
    Copithorne, David
    Behm, David G.
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2014, 39 (12) : 1338 - 1344
  • [13] On the maximum work of human muscles especially the flexors of the elbow
    Hansen, TE
    Lindhard, J
    JOURNAL OF PHYSIOLOGY-LONDON, 1923, 57 (05): : 287 - 300
  • [14] CHANGES IN WRIST AND FOREARM CONFIGURATION WITH GRASP AND ISOMETRIC CONTRACTION OF ELBOW FLEXORS
    SCHUIND, FA
    LINSCHEID, RL
    AN, KN
    CHAO, EYS
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (04): : 698 - 703
  • [15] Perception of Effort Changes Following an Isometric Fatiguing Exercise of Elbow Flexors
    Lampropoulou, Sofia I.
    Nowicky, Alexander V.
    MOTOR CONTROL, 2014, 18 (02) : 146 - 164
  • [16] Diurnal rhythm of the muscular performance of elbow flexors during isometric contractions
    Gauthier, A
    Davenne, D
    Martin, A
    Cometti, G
    VanHoecke, J
    CHRONOBIOLOGY INTERNATIONAL, 1996, 13 (02) : 135 - 146
  • [17] Effect of elbow joint angle on the magnitude of muscle damage to the elbow flexors
    Nosaka, K
    Sakamoto, K
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (01): : 22 - 29
  • [18] COMPARISON BETWEEN THE FATIGUEABILITY OF THE INSPIRATORY MUSCLES AND THE FLEXORS OF THE ELBOW DURING ISOMETRIC CONTRACTIONS
    GANDEVIA, SC
    MCKENZIE, DK
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (04): : 207 - 207
  • [19] Changes in fluctuation of isometric force following eccentric and concentric exercise of the elbow flexors
    Lavender, AP
    Nosaka, K
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (03) : 235 - 240
  • [20] Muscle damage protective effect by two maximal isometric contractions on maximal eccentric exercise of the elbow flexors of the contralateral arm
    Chen, T. C.
    Lin, M. J.
    Chen, H. L.
    Lai, J. H.
    Yu, H. I.
    Nosaka, K.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2018, 28 (04) : 1354 - 1360