Is maximum isometric muscle stress the same among prime elbow flexors?

被引:15
|
作者
Li, Le
Tong, Kaiyu [1 ]
Song, Rong
Koo, Terry K. K.
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Kowloon, Hong Kong, Peoples R China
[2] New York Chiropract Coll, Dept Res, Foot Levelers Biomech Res Lab, Seneca Falls, NY 13148 USA
关键词
elbow; maximum isometric muscle stress; musculotendon parameters; musculoskeletal model; ultrasonography;
D O I
10.1016/j.clinbiomech.2007.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Previous musculoskeletal modeling studies have adopted the assumption of the same maximum isometric muscle stress among the prime elbow flexors. This study aimed at estimating the maximum isometric muscle stress based on subject-specific modeling parameters measured in vivo and validating that assumption. Methods. Subject-specific musculoskeletal models of the upper limbs of five normal subjects were developed, which incorporated anthropometrically scaled graphics-based geometrical models and Hill-type musculotendon models of the prime elbow flexors. B-mode ultrasound technique was employed to measure the muscle optimal length and pennation angle of each prime elbow flexor, and these architectural parameters were inputted into the model to reduce the number of unknown parameters to be optimized. To allow changes of individual maximum isometric muscle force of the prime elbow flexors, optimizations were conducted by minimizing the root mean square difference between the predicted and measured isometric torque-angle curves. Maximum isometric muscle stress of each prime elbow flexor was estimated by dividing the maximum isometric muscle force with the corresponding physiological cross-sectional area. Findings. Our findings showed that maximum isometric muscle stress among the prime elbow flexors was not significantly different from each other. Thus it appears that it is reasonable to assume the same value for maximum isometric muscle stress for all prime elbow flexors in musculoskeletal modeling studies. Interpretation. Latest medical imaging techniques such as ultrasound for the estimation of musculotendon parameters would provide an alterative method to obtain the muscle architecture parameters noninvasively. The subject-specific musculotendon parameters estimated in this study could be used for developing the neuromusculoskeletal model to predict muscle force and evaluate muscle functions. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:874 / 883
页数:10
相关论文
共 50 条
  • [1] Muscle damage produced by isometric contractions in human elbow flexors
    Allen, Trevor J.
    Jones, Tyson
    Tsay, Anthony
    Morgan, David L.
    Proske, Uwe
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 124 (02) : 388 - 399
  • [2] EVIDENCE THAT MAXIMUM MUSCLE STRESS IS NOT A CONSTANT - DIFFERENCES IN SPECIFIC TENSION IN ELBOW FLEXORS AND EXTENSORS
    BUCHANAN, TS
    MEDICAL ENGINEERING & PHYSICS, 1995, 17 (07) : 529 - 536
  • [3] A COMPARISON OF CONCENTRIC ECCENTRIC AND ISOMETRIC STRENGTH OF ELBOW FLEXORS
    DOSS, WS
    KARPOVICH, PV
    JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (02) : 351 - +
  • [4] Comparison in muscle damage between maximal voluntary and electrically evoked isometric contractions of the elbow flexors
    Jubeau, Marc
    Muthalib, Makii
    Millet, Guillaume Y.
    Maffiuletti, Nicola A.
    Nosaka, Kazunori
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (02) : 429 - 438
  • [5] Comparison in muscle damage between maximal voluntary and electrically evoked isometric contractions of the elbow flexors
    Marc Jubeau
    Makii Muthalib
    Guillaume Y. Millet
    Nicola A. Maffiuletti
    Kazunori Nosaka
    European Journal of Applied Physiology, 2012, 112 : 429 - 438
  • [6] MOTOR-UNIT INVOLVEMENT AND TENSION DURING MAXIMUM, VOLUNTARY CONCENTRIC, ECCENTRIC, AND ISOMETRIC CONTRACTIONS OF ELBOW FLEXORS
    RODGERS, KL
    BERGER, RA
    FRANKS, BD
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1973, 5 (01): : 58 - 58
  • [7] RHYTHMIC ISOMETRIC FATIGUE PATTERNS OF ELBOW FLEXORS AND KNEE EXTENSORS
    ORDWAY, GA
    KEARNEY, JT
    STULL, GA
    RESEARCH QUARTERLY, 1977, 48 (04): : 734 - 740
  • [8] Angle-specific impairment of elbow flexors strength after isometric exercise at long muscle length
    Philippou, A
    Maridaki, M
    Bogdanis, GC
    JOURNAL OF SPORTS SCIENCES, 2003, 21 (10) : 859 - 865
  • [9] Effect of two maximal isometric contractions on eccentric exercise-induced muscle damage of the elbow flexors
    Trevor C. Chen
    Hsin-Lian Chen
    Ming-Ju Lin
    Che-Hsiu Chen
    Alan J. Pearce
    Kazunori Nosaka
    European Journal of Applied Physiology, 2013, 113 : 1545 - 1554
  • [10] MOTOR-UNIT INVOLVEMENT AND TENSION DURING MAXIMUM, VOLUNTARY CONCENTRIC, ECCENTRIC, AND ISOMETRIC CONTRACTIONS OF ELBOW FLEXORS
    RODGERS, KL
    BERGER, RA
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1974, 6 (04): : 253 - 259