Dosimetric Dependence on Variations of the Lung Density and Geometry: A Monte Carlo Evaluation Using Virtual Dynamic Heterogeneous Phantom

被引:0
|
作者
Mylrajan, L.
Chow, J.
Grigorov, G.
机构
关键词
D O I
10.1118/1.3612638
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-676
引用
收藏
页码:3645 / +
页数:2
相关论文
共 50 条
  • [1] Variations of lung density and geometry on inhomogeneity correction algorithms: A Monte Carlo dosimetric evaluation
    Chow, James C. L.
    Leung, Michael K. K.
    Van Dyk, Jake
    [J]. MEDICAL PHYSICS, 2009, 36 (08) : 3619 - 3630
  • [2] Technical and dosimetric implications of respiratory induced density variations in a heterogeneous lung phantom
    Dennis J. Mohatt
    Tianjun Ma
    David B. Wiant
    Naveed M. Islam
    Jorge Gomez
    Anurag K. Singh
    Harish K. Malhotra
    [J]. Radiation Oncology, 13
  • [3] Technical and dosimetric implications of respiratory induced density variations in a heterogeneous lung phantom
    Mohatt, Dennis J.
    Ma, Tianjun
    Wiant, David B.
    Islam, Naveed M.
    Gomez, Jorge
    Singh, Anurag K.
    Malhotra, Harish K.
    [J]. RADIATION ONCOLOGY, 2018, 13
  • [4] Dosimetric evaluation in brachytherapy and teletherapy for prostate cancer using Monte Carlo simulation and anatomically realistic virtual anthropomorphic phantom
    Santos, William S.
    Xavier, Douglas A. A.
    Santos, Carla J.
    Neves, Lucio P.
    Belinato, Walmir
    Valenca, Jaoa V. B.
    Perini, Ana P.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 209
  • [5] Dosimetric verification of lung phantom calculated by collapsed cone convolution: A Monte Carlo and experimental evaluation
    Najafzadeh, Milad
    Nickfarjam, Abolfzal
    Jabbari, Keyvan
    Markel, Daniel
    Chow, James C. L.
    Takabi, Fatemeh Shirani
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (01) : 161 - 175
  • [6] Evaluation of dosimetric parameters for various 192ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation
    Devan, Krishnamurthy
    Aruna, Prakasarao
    Manigandan, Durai
    Bharanidharan, Ganesan
    Subbaiah, Kamatam Venkata
    Sunny, Chiravath Sunil
    Ganesan, Singaravelu
    [J]. MEDICAL DOSIMETRY, 2007, 32 (04) : 305 - 315
  • [7] Monte Carlo perturbation methods using "virtual density" theory for calculating reactivity due to geometry change
    Yamamoto, Toshihiro
    Sakamoto, Hiroki
    [J]. ANNALS OF NUCLEAR ENERGY, 2018, 119 : 362 - 373
  • [8] Dosimetric evaluation of lung treatment plans produced by the Prowess Panther system using Monte Carlo simulation
    Luong Thi Oanh
    Duong Thanh Tai
    Truong Thi Hong Loan
    Trinh Hong Minh
    Truong Van Minh
    Chow, James C. L.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [9] Clinical Evaluation of RTOG 0813 Dosimetric Criteria for Lung SABR Using iPlan Monte Carlo Algorithm
    Pokhrel, D.
    Badkul, R.
    Jiang, H.
    Estes, C.
    Park, J.
    Wang, F.
    Kumar, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S627 - S627
  • [10] Monte Carlo dosimetric evaluation of using high energy vs low energy beams in low density materials
    Stathakis, S
    Tsiakalos, M
    Plataniotis, G
    Kappas, K
    Theodorou, K
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1903 - 1903