Dosimetric evaluation in brachytherapy and teletherapy for prostate cancer using Monte Carlo simulation and anatomically realistic virtual anthropomorphic phantom

被引:0
|
作者
Santos, William S. [1 ,2 ]
Xavier, Douglas A. A. [2 ]
Santos, Carla J. [2 ]
Neves, Lucio P. [1 ,2 ]
Belinato, Walmir [3 ]
Valenca, Jaoa V. B. [4 ]
Perini, Ana P. [1 ,2 ]
机构
[1] Fed Univ Uberlandia INFIS UFU, Phys Inst, Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Elect Engn Fac, Grad Program Biomed Engn PPGEB UFU, Uberlandia, MG, Brazil
[3] Fed Inst Bahia IFBA, Vitoria Da Conquista, BA, Brazil
[4] Fed Univ Hlth Sci Porto Alegre UFCSPA, Porto Alegre, RS, Brazil
关键词
Radiotherapy; 192Ir; 3D-CRT; 4-Fields; Dosimetry; Monte Carlo simulation; Virtual anthropomorphic phantom; HIGH-DOSE-RATE; PROTON RADIOTHERAPY; ENERGY-SPECTRA; RADIATION; PHOTON; NEUTRON; THERAPY; IMRT; IMPACT; BREAST;
D O I
10.1016/j.radphyschem.2023.111000
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The benefits that radiotherapy provides to the patient are unquestionable. However, there is growing concern about the increased risk of radiation-induced secondary cancer and the late damage to organs and tissues associated with the treatment. In this sense, the main objective of this study was to determine the radiation doses in the organs and tissues of the prostate cancer patient for two radiotherapy options, using the Monte Carlo code MCNPx2.7.0. The patient was represented by the ICRP 110 reference virtual anthropomorphic phantom and underwent brachytherapy with a192Ir source, Nucletron Microselectron V2 model, and alternatively, conventional 3D-CRT radiotherapy with an 18 MV X-ray beam from a Varian 2100c medical linear accelerator with 4-field planning (anteroposterior, 0 degrees; posteroanterior, 180 degrees; left lateral, 90 degrees; and right lateral, 270 degrees). A set of conversion factors (CF) for equivalent and effective dose were determined. The obtained results showed that in the more distant organs related to the prostate, such as the lung, brain, and salivary glands, the contribution of scattered radiation decreases, especially when brachytherapy is used. Comparing the two treatment modalities, the CF for effective dose per therapeutic dose was 42% lower when 192Ir was chosen as the main form of treatment. The CF values for photon equivalent doses calculated in 3D-CRT 4-fields are among one and two orders of magnitude higher than 192Ir therapy. These differences are even higher when the neutron equivalent dose in 3D-CRT is considered. In this way, the tools and methodology presented significantly improve the previously used to accurately estimate the equivalent doses in organs and tissues, which is the best quantity to assess the risk of inducing secondary cancer of healthy organs and tissues of patients undergoing treatment with radiotherapy.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Monte Carlo simulation with penelope and a realistic anthropomorphic phantom described by triangle meshes
    Badal, A.
    Kyprianou, I.
    Badano, A.
    Sempau, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S46 - S46
  • [2] Monte Carlo simulation of a realistic anatomical phantom described by triangle meshes: Application to prostate brachytherapy imaging
    Badal, Andreu
    Kyprianou, Lacovos
    Badano, Aldo
    Sempau, Josep
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) : 99 - 103
  • [3] Evaluation of Dosimetric Parameters of Two Brachytherapy Ophthalmic Sources Using Monte Carlo Simulation
    Ramon, P.
    Quevedo, A.
    Pianoschi, T.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [4] Calculated organ doses from selected prostate treatment plans using Monte Carlo simulations and an anatomically realistic computational phantom
    Bednarz, Bryan
    Hancox, Cindy
    Xu, X. George
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17): : 5271 - 5286
  • [5] Evaluation of dosimetric parameters for various 192ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation
    Devan, Krishnamurthy
    Aruna, Prakasarao
    Manigandan, Durai
    Bharanidharan, Ganesan
    Subbaiah, Kamatam Venkata
    Sunny, Chiravath Sunil
    Ganesan, Singaravelu
    [J]. MEDICAL DOSIMETRY, 2007, 32 (04) : 305 - 315
  • [6] Dosimetric Dependence on Variations of the Lung Density and Geometry: A Monte Carlo Evaluation Using Virtual Dynamic Heterogeneous Phantom
    Mylrajan, L.
    Chow, J.
    Grigorov, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3645 - +
  • [7] Design of a protective shield for a radiological emergency intervention using Monte Carlo simulation and an anthropomorphic phantom
    El-ouardi, Youssef
    Aknouch, Adil
    Dadouch, Ahmed
    Mouhib, Mohammed
    Benmessaoud, Mounir
    [J]. RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2022, 61 (03) : 425 - 433
  • [8] Design of a protective shield for a radiological emergency intervention using Monte Carlo simulation and an anthropomorphic phantom
    Youssef El-ouardi
    Adil Aknouch
    Ahmed Dadouch
    Mohammed Mouhib
    Mounir Benmessaoud
    [J]. Radiation and Environmental Biophysics, 2022, 61 : 425 - 433
  • [9] Monte Carlo simulation of photoneutron dose in radiotherapy with linear accelerators using an anthropomorphic voxel phantom
    Frankl, M.
    Macian, R.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 749 - 750
  • [10] Evaluation of fetal, medical and occupational exposure in ERCP procedures using Monte Carlo simulation and virtual anthropomorphic phantoms
    Santos, William S.
    Souza, Lucas W. G.
    Neves, Lucio P.
    Perini, Ana P.
    Santos, Carla J.
    Belinato, Walmir
    Caldas, Linda V. E.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 177