Technical and dosimetric implications of respiratory induced density variations in a heterogeneous lung phantom

被引:8
|
作者
Mohatt, Dennis J. [1 ,2 ]
Ma, Tianjun [1 ,2 ]
Wiant, David B. [3 ]
Islam, Naveed M. [1 ,2 ]
Gomez, Jorge [2 ]
Singh, Anurag K. [2 ]
Malhotra, Harish K. [1 ,2 ]
机构
[1] SUNY Buffalo, Med Phys Program, Jacobs Sch Med & Biomed Sci, Buffalo, NY 14214 USA
[2] Roswell Pk Canc Inst, Dept Radiat Med, Buffalo, NY 14293 USA
[3] Cone Hlth Canc Ctr, Radiat Oncol, Greensboro, NC 27403 USA
来源
RADIATION ONCOLOGY | 2018年 / 13卷
关键词
Lung SBRT; Acuros XB; Respiratory induced tissue heterogeneity; Phase weighted density; BODY RADIATION-THERAPY; DOSE CALCULATION ALGORITHMS; MONTE-CARLO; 3; GENERATIONS; CT DATASETS; ACUROS XB; CANCER; RADIOTHERAPY; AVERAGE; SBRT;
D O I
10.1186/s13014-018-1110-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Stereotactic Body Radiotherapy (SBRT) is an ablative dose delivery technique which requires the highest levels of precision and accuracy. Modeling dose to a lung treatment volume has remained a complex and challenging endeavor due to target motion and the low density of the surrounding media. When coupled together, these factors give rise to pulmonary induced tissue heterogeneities which can lead to inaccuracies in dose computation. This investigation aims to determine which combination of imaging techniques and computational algorithms best compensates for time dependent lung target displacements. Methods: A Quasar phantom was employed to simulate respiratory motion for target ranges up to 3 cm. 4DCT imaging was used to generate Average Intensity Projection (AIP), Free Breathing (FB), and Maximum Intensity Projection (MIP) image sets. In addition, we introduce and compare a fourth dataset for dose computation based on a novel phase weighted density (PWD) technique. All plans were created using Eclipse version 13.6 treatment planning system and calculated using the Analytical Anisotropic Algorithm and Acuros XB. Dose delivery was performed using Truebeam STx linear accelerator where radiochromic film measurements were accessed using gamma analysis to compare planned versus delivered dose. Results: In the most extreme case scenario, the mean CT difference between FB and MIP datasets was found to be greater than 200 HU. The near maximum dose discrepancies between AM and AXB algorithms were determined to be marginal (< 22%), with a greater variability occurring within the near minimum dose regime (< 7%). Radiochromatic film verification demonstrated all AIP and FB based computations exceeded 98% passing rates under conventional radiotherapy tolerances (gamma 3%, 3 mm). Under more stringent SBRT tolerances (gamma 3%, 1 mm), the AIP and FB based treatment plans exhibited higher pass rates (> 85%) when compared to MIP and PWD (< 85%) for AAA computations. For AXB, however, the delivery accuracy for all datasets were greater than 85% (gamma 3%,1 mm), with a corresponding reduction in overall lung irradiation. Conclusions: Despite the substantial density variations between computational datasets over an extensive range of target movement, the dose difference between CT datasets is small and could not be quantified with ion chamber. Radiochromatic film analysis suggests the optimal CT dataset is dependent on the dose algorithm used for evaluation. With AAA, AIP and FB resulted in the best conformance between measured versus calculated dose for target motion ranging up to 3 cm under both conventional and SBRT tolerance criteria. With AXB, pass rates improved for all datasets with the PWD technique demonstrating slightly better conformity over AIP and FB based computations (gamma 3%, 1 mm). As verified in previous studies, our results confirm a clear advantage in delivery accuracy along with a relative decrease in calculated dose to the lung when using Acuros XB over AAA.
引用
收藏
页数:14
相关论文
共 28 条
  • [1] Technical and dosimetric implications of respiratory induced density variations in a heterogeneous lung phantom
    Dennis J. Mohatt
    Tianjun Ma
    David B. Wiant
    Naveed M. Islam
    Jorge Gomez
    Anurag K. Singh
    Harish K. Malhotra
    [J]. Radiation Oncology, 13
  • [2] Dosimetric Dependence on Variations of the Lung Density and Geometry: A Monte Carlo Evaluation Using Virtual Dynamic Heterogeneous Phantom
    Mylrajan, L.
    Chow, J.
    Grigorov, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3645 - +
  • [3] DOSIMETRIC CONSEQUENCES OF LUNG DENSITY VARIATIONS IN CARCINOMA OF THE LUNG
    FULLERTON, GD
    BOYER, AL
    MIRA, J
    MOK, EC
    [J]. MEDICAL PHYSICS, 1981, 8 (04) : 577 - 577
  • [4] An Advanced Deformable Lung Phantom for Analyzing the Dosimetric Impact of Respiratory Motion
    Shin, D.
    Kang, S.
    Kim, D.
    Kim, T.
    Kim, K.
    Cho, M.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3638 - 3638
  • [5] The effect of respiratory induced density variations on non-TOF PET quantitation in the lung
    Holman, Beverley F.
    Cuplov, Vesna
    Hutton, Brian F.
    Groves, Ashley M.
    Thielemans, Kris
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (08): : 3148 - 3163
  • [6] Dosimetric Verification of Respiratory Gated VMAT for Lung SBRT Using 3-D Printed Lung Phantom
    Yoon, K. J.
    Kwak, J.
    Cho, B.
    Song, S. Y.
    Lee, S. W.
    Ahn, S. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E548 - E548
  • [7] Variations of lung density and geometry on inhomogeneity correction algorithms: A Monte Carlo dosimetric evaluation
    Chow, James C. L.
    Leung, Michael K. K.
    Van Dyk, Jake
    [J]. MEDICAL PHYSICS, 2009, 36 (08) : 3619 - 3630
  • [8] Respiratory motion-management in stereotactic body radiation therapy for lung cancer - A dosimetric comparison in an anthropomorphic lung phantom (LuCa)
    Ehrbar, Stefanie
    Perrin, Rosalind
    Peroni, Marta
    Bernatowicz, Kinga
    Parkel, Thomas
    Pytko, Izabela
    Klock, Stephan
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    Weber, Damien Charles
    Lomax, Antony
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 121 (02) : 328 - 334
  • [9] A customizable anthropomorphic phantom for dosimetric verification of 3D-printed lung, tissue, and bone density materials
    Tino, Rance Bolislis
    Yeo, Adam Unjin
    Brandt, Milan
    Leary, Martin
    Kron, Tomas
    [J]. MEDICAL PHYSICS, 2022, 49 (01) : 52 - 69
  • [10] Feasibility of Using a Programmable Respiratory Motion Phantom for QA and Assessment of Dosimetric Implications of Breathing Motion During Radiation Therapy
    Publicover, J.
    Vandermeer, A.
    Norrlinger, B.
    Alasti, H.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)