Palliative radiotherapy for thoracic spine metastases: Dosimetric advantage of three-dimensional conformal plans

被引:6
|
作者
Yeo, Seung-Gu [1 ]
机构
[1] Soonchunhyang Univ, Soonchunhyang Univ Hosp, Dept Radiat Oncol, Coll Med, Cheonan 330721, South Korea
关键词
spine; metastases; palliation; three-dimensional conformal radiotherapy; dosimetry; BONE METASTASES; BREAST-CANCER; HEART-DISEASE; LUNG-CANCER; WOMEN; RISK;
D O I
10.3892/ol.2015.3205
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to investigate the dosimetric advantages of three-dimensional conformal radiation therapy (3DCRT) for thoracic spine metastases and compare it with conventional two-dimensional (2D) plans. Radiation therapy (RT) planning data of 10 patients with mid-to-low thoracic spine metastases were analyzed. Computed tomography simulation was performed and the planning target volume (PTV), heart, esophagus, lung and spinal cord were contoured. The 3DCRT plan comprised one posteroanterior (PA) field and two posterior oblique fields. The 2D plans used a single PA field or opposed anteroposterior (AP)/PA fields. The prescription dose of radiation was 30 Gy in 10 fractions. All comparisons of the maximum or mean doses to the organs at risk or the PTV, between two of the three RT plans, demonstrated statistically significant differences (P<0.05), with the exception of the mean esophageal doses between the single PA vs. AP/PA (P=0.285) plans. The mean heart doses were 15.0 +/- 3.1 Gy in single PA, 17.3 +/- 4.3 Gy in AP/PA and 8.5 +/- 1.7 Gy using 3DCRT. The median reduction rates using 3DCRT were 38.9% compared with single PA (range, 29.4-58.5%) or 47.5% relative to AP/PA (range, 34.5-67.1%). The mean esophageal doses were 17.9 +/- 2.3 Gy in single PA, 18.2 +/- 2.2 Gy in AP/PA and 15.3 +/- 1.9 Gy in 3DCRT. The median reduction rate using 3DCRT was 12.8% compared with single PA or 15.6% relative to AP/PA. Compared with the single PA or AP/PA 2D plan, 3DCRT reduced the median dose by 13.7 or 1.9% of the maximum spinal cord dose, respectively, and 14.7 or 2.9% of the maximum PTV dose, respectively. The mean lung doses were 2.7 +/- 0.7 Gy in single PA, 2.6 +/- 0.7 Gy in AP/PA and 5.1 +/- 1.0 Gy in 3DCRT. In conclusion, 3DCRT for mid-to-low thoracic spine metastases demonstrated significant dosimetric advantages by reducing the unnecessary irradiation of critical organs, particularly the heart, and by achieving a homogeneous target dose.
引用
收藏
页码:497 / 501
页数:5
相关论文
共 50 条
  • [21] Field-in-Field Technique Improves the Dosimetric Outcome of Treatment Plans Compared with the Three-Dimensional Conformal Radiation Therapy for Esophageal Cancer Radiotherapy
    Ghadimi, Behnam
    Jabbari, Nasrollah
    Karimkhani, Laya
    Mostafanezhad, Kamal
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2018, 28 (02): : 79 - 85
  • [22] A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes
    Zhang, Ji-Bin
    Zhao, Li-Rong
    Cui, Tian-Xiang
    Chen, Xie-Wan
    Yang, Qiao
    Zhou, Yi-Bing
    Chen, Zheng-Tang
    Zhang, Shao-Xiang
    Sun, Jian-Guo
    ONCOLOGY LETTERS, 2018, 15 (04) : 5634 - 5642
  • [23] A deep learning pipeline for real-time conformal palliative radiotherapy of spine metastases
    Haidari, Ali-reza
    Granville, Dal
    Ali, Elsayed
    MEDICAL PHYSICS, 2024, 51 (08) : 5791 - 5792
  • [24] Digestive toxicity after conformal radiotherapy for palliative cervico-thoracic spinal metastases
    Peyraga, G.
    Caron, D.
    Metayer, Y.
    Pointreau, Y.
    Denis, F.
    Ganem, G.
    Lafond, C.
    Roche, S.
    Dupuis, O.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S745 - S745
  • [25] Palliative Radiotherapy for Bleeding from Unresectable Gastric Cancer Using Three-Dimensional Conformal Technique
    Kawabata, Hideaki
    Fujii, Takashi
    Yamamoto, Tetsuya
    Satake, Hiroaki
    Yamaguchi, Katsutoshi
    Okazaki, Yuji
    Nakase, Kojiro
    Miyata, Masatoshi
    Motoi, Shigehiro
    BIOMEDICINES, 2022, 10 (06)
  • [26] Digestive toxicities after palliative three-dimensional conformal radiation therapy (3D-CRT) for cervico-thoracic spinal metastases
    Peyraga, Guillaume
    Caron, Delphine
    Lizee, Thibaut
    Metayer, Yann
    Septans, Anne-Lise
    Pointreau, Yoann
    Denis, Fabrice
    Ganem, Gerard
    Lafond, Cedrik
    Roche, Sophie
    Dupuis, Olivier
    SUPPORTIVE CARE IN CANCER, 2018, 26 (06) : 1897 - 1903
  • [27] Digestive toxicities after palliative three-dimensional conformal radiation therapy (3D-CRT) for cervico-thoracic spinal metastases
    Guillaume Peyraga
    Delphine Caron
    Thibaut Lizee
    Yann Metayer
    Anne-Lise Septans
    Yoann Pointreau
    Fabrice Denis
    Gerard Ganem
    Cedrik Lafond
    Sophie Roche
    Olivier Dupuis
    Supportive Care in Cancer, 2018, 26 : 1897 - 1903
  • [28] The Effect of the Number of Fields on Radiotherapy Plans of Breast Cancer Patients in Three-Dimensionally Conformal Radiotherapy Plans: Dosimetric Studies
    Bazeed, Zezy Mansour
    Attalla, Ehab Maarouf
    Awad, Ibrahim Ali Mohamed
    Hamid, Maysa Ismail Abdel
    Sarhan, Afaf
    MIDDLE EAST JOURNAL OF CANCER, 2021, 12 (04) : 516 - 526
  • [29] A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ions
    Karger, CP
    Jäkel, O
    Hartmann, GH
    Heeg, P
    MEDICAL PHYSICS, 1999, 26 (10) : 2125 - 2132
  • [30] Dosimetric Comparisons of Three-dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy in Whole Abdominopelvic Radiotherapy for Gynecologic Malignancy
    Kim, Yong Bae
    Kim, Joo Ho
    Jeong, Kyung Keun
    Seong, Jinsil
    Suh, Chang Ok
    Kim, Gwi Eon
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 369 - 377