A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes

被引:2
|
作者
Zhang, Ji-Bin [1 ]
Zhao, Li-Rong [1 ]
Cui, Tian-Xiang [1 ]
Chen, Xie-Wan [2 ]
Yang, Qiao [1 ]
Zhou, Yi-Bing [1 ]
Chen, Zheng-Tang [1 ]
Zhang, Shao-Xiang [3 ]
Sun, Jian-Guo [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Canc Inst, Peoples Liberat Army, 83 Xinqiao St, Chongqing 400037, Peoples R China
[2] Third Mil Med Univ, Coll Basic Med, Dept Med English, Chongqing 400038, Peoples R China
[3] Third Mil Med Univ, Coll Basic Med, Dept Digital Med, Chongqing 400038, Peoples R China
基金
中国国家自然科学基金;
关键词
mediastinal lymph nodes; three-dimensional reconstruction; radiation phantom; plan optimization; dosimetric measurement; thoracic radiotherapy; CELL LUNG-CANCER; HELICAL TOMOTHERAPY; RADIATION-THERAPY; TISSUE; IMRT; VMAT; VERIFICATION; BENEFITS; SYSTEM; ORGANS;
D O I
10.3892/ol.2018.8084
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to investigate the optimal strategy and dosimetric measurement of thoracic radiotherapy based on three-dimensional (3D) modeling of mediastinal lymph nodes (MLNs). A 3D model of MLNs was constructed from a Chinese Visible Human female dataset. Image registration and fusion between reconstructed MLNs and original chest computed tomography (CT) images was conducted in the Eclipse T treatment planning system (TPS). There were three plans, including 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), which were designed based on 10 cases of simulated lung lesions (SLLs) and MLNs. The quality of these plans was evaluated via examining indexes, including conformity index (CI), homogeneity index and clinical target volume (CTV) coverage. Dose-volume histogram analysis was performed on SLL, MLNs and organs at risk (OARs). A Chengdu Dosimetric Phantom (CDP) was then drilled at specific MLNs according to 20 patients with thoracic tumors and of a medium-build. These plans were repeated on fused MLNs and CDP CT images in the Eclipse T TPS. Radiation doses at the SLLs and MLNs of the CDP were measured and compared with calculated doses. The established 3D MLN model demonstrated the spatial location of MLNs and adjacent structures. Precise image registration and fusion were conducted between reconstructed MLNs and the original chest CT or CDP CT images. IMRT demonstrated greater values in CI, CTV coverage and OAR (lungs and spinal cord) protection, compared with 3D-CRT and VMAT (P< 0.05). The deviation between the measured and calculated doses was within +/- 10% at SLL, and at the 2R and 7th MLN stations. In conclusion, the 3D MLN model can benefit plan optimization and dosimetric measurement of thoracic radiotherapy, and when combined with CDP, it may provide a tool for clinical dosimetric monitoring.
引用
收藏
页码:5634 / 5642
页数:9
相关论文
共 50 条
  • [1] Palliative radiotherapy for thoracic spine metastases: Dosimetric advantage of three-dimensional conformal plans
    Yeo, Seung-Gu
    ONCOLOGY LETTERS, 2015, 10 (01) : 497 - 501
  • [2] Extraction of Cervical Lymph Nodes Based on Three-Dimensional Image Registration
    Shime, Nozomi
    Kamiya, Tohru
    Ishida, Takayuki
    2021 21ST INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2021), 2021, : 1792 - 1795
  • [3] Location of three mediastinal lymph node stations in a three-dimensional model
    Yksnoy, Oyvind
    Hoff, Dag Arne Lihaug
    Gronberg, Bjorn Henning
    Sorhaug, Sveinung
    Roth, Kjetil
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [4] Dosimetric study of the interplay effect using three-dimensional motion phantom in proton pencil beam scanning treatment of moving thoracic tumours
    Grewal, Hardev S.
    Ahmad, Salahuddin
    Jin, Hosang
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 22
  • [5] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [6] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [7] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [8] Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: a dynamic phantom study
    Raymond R. Raylman
    Paul V. Kison
    Richard L. Wahl
    European Journal of Nuclear Medicine, 1999, 26 : 39 - 45
  • [9] Capabilities of two- and three-dimensional FDG-PET for detecting small lesions and lymph nodes in the upper torso: a dynamic phantom study
    Raylman, RR
    Kison, PV
    Wahl, RL
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (01) : 39 - 45
  • [10] Three-dimensional radiopharmaceutical-excited fluorescence imaging of lymph nodes
    Guo, Hongbo
    He, Xiaowei
    Liu, Muhan
    Zhang, Zeyu
    Hu, Zhenhua
    Tian, Jie
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,