A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes

被引:2
|
作者
Zhang, Ji-Bin [1 ]
Zhao, Li-Rong [1 ]
Cui, Tian-Xiang [1 ]
Chen, Xie-Wan [2 ]
Yang, Qiao [1 ]
Zhou, Yi-Bing [1 ]
Chen, Zheng-Tang [1 ]
Zhang, Shao-Xiang [3 ]
Sun, Jian-Guo [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Canc Inst, Peoples Liberat Army, 83 Xinqiao St, Chongqing 400037, Peoples R China
[2] Third Mil Med Univ, Coll Basic Med, Dept Med English, Chongqing 400038, Peoples R China
[3] Third Mil Med Univ, Coll Basic Med, Dept Digital Med, Chongqing 400038, Peoples R China
基金
中国国家自然科学基金;
关键词
mediastinal lymph nodes; three-dimensional reconstruction; radiation phantom; plan optimization; dosimetric measurement; thoracic radiotherapy; CELL LUNG-CANCER; HELICAL TOMOTHERAPY; RADIATION-THERAPY; TISSUE; IMRT; VMAT; VERIFICATION; BENEFITS; SYSTEM; ORGANS;
D O I
10.3892/ol.2018.8084
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to investigate the optimal strategy and dosimetric measurement of thoracic radiotherapy based on three-dimensional (3D) modeling of mediastinal lymph nodes (MLNs). A 3D model of MLNs was constructed from a Chinese Visible Human female dataset. Image registration and fusion between reconstructed MLNs and original chest computed tomography (CT) images was conducted in the Eclipse T treatment planning system (TPS). There were three plans, including 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), which were designed based on 10 cases of simulated lung lesions (SLLs) and MLNs. The quality of these plans was evaluated via examining indexes, including conformity index (CI), homogeneity index and clinical target volume (CTV) coverage. Dose-volume histogram analysis was performed on SLL, MLNs and organs at risk (OARs). A Chengdu Dosimetric Phantom (CDP) was then drilled at specific MLNs according to 20 patients with thoracic tumors and of a medium-build. These plans were repeated on fused MLNs and CDP CT images in the Eclipse T TPS. Radiation doses at the SLLs and MLNs of the CDP were measured and compared with calculated doses. The established 3D MLN model demonstrated the spatial location of MLNs and adjacent structures. Precise image registration and fusion were conducted between reconstructed MLNs and the original chest CT or CDP CT images. IMRT demonstrated greater values in CI, CTV coverage and OAR (lungs and spinal cord) protection, compared with 3D-CRT and VMAT (P< 0.05). The deviation between the measured and calculated doses was within +/- 10% at SLL, and at the 2R and 7th MLN stations. In conclusion, the 3D MLN model can benefit plan optimization and dosimetric measurement of thoracic radiotherapy, and when combined with CDP, it may provide a tool for clinical dosimetric monitoring.
引用
收藏
页码:5634 / 5642
页数:9
相关论文
共 50 条
  • [21] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    JOURNAL OF BUON, 2015, 20 (01): : 248 - 252
  • [22] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy in Salvage Radiotherapy for PSA Relapse after Radical Prostatectomy
    Tomita, Natsuo
    Shimizu, Hidetoshi
    Kodaira, Takeshi
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (05) : 581 - 587
  • [23] Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer
    Adeneye, Samuel
    Akpochafor, Michael
    Habeebu, Muhammad
    Omojola, Akintayo
    Joseph, Adedayo
    Awhariado, John
    Durosinnmi-Etti, Abayomi
    Aweda, Moses
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 104 - 111
  • [24] Three-dimensional thoracic modeling for an anatomical compatibility study of the implantable total artificial heart
    Zhang, B
    Masuzawa, T
    Tatsumi, E
    Taenaka, Y
    Uyama, C
    Takano, H
    Takamiya, M
    ARTIFICIAL ORGANS, 1999, 23 (03) : 229 - 234
  • [25] Three-dimensional conformal radiotherapy for mediastinal lympha node recurrence of esophageal cancer after postoperativ radiotherapy
    Shao, Qian
    Sun, Tao
    Liang, Chao-qian
    Zhang, Ying-jie
    Xu, Min
    Li, Ji-bin
    Yu, Jin-ming
    JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S948 - S948
  • [26] Involved-field three-dimensional conformal radiotherapy vs helical tomotherapy for female patients with early-stage mediastinal Hodgkin lymphoma: A dosimetric comparative study
    Pernin, V.
    Zygogianni, A.
    Capezzali, G.
    Peurien, D.
    Amessis, M.
    Zefkili, S.
    Kirova, Y.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S838 - S838
  • [27] Dose distribution analysis of axillary lymph nodes for three-dimensional conformal radiotherapy with a field-in-field technique for breast cancer
    Ohashi, T.
    Takeda, A.
    Shigematsu, N.
    Fukuda, J.
    Sanuki, N.
    Ameniya, A.
    Kubo, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S177 - S177
  • [28] DOSE DISTRIBUTION ANALYSIS OF AXILLARY LYMPH NODES FOR THREE-DIMENSIONAL CONFORMAL RADIOTHERAPY WITH A FIELD-IN-FIELD TECHNIQUE FOR BREAST CANCER
    Ohashi, Toshio
    Takeda, Atsuya
    Shigematsu, Naoyuki
    Fukada, Junichi
    Sanuki, Naoko
    Amemiya, Atsushi
    Kubo, Atsushi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01): : 80 - 87
  • [29] Comparative dosimetric evaluation of three-dimensional conformal and stereotactic radiotherapy for treatment of intracranial tumors
    Gupta, Manoj
    Babaiah, M.
    Kumar, M. Dinesh
    Hirapara, Pushpendra H.
    Patidar, Arvind K.
    Walke, Rahul V.
    JOURNAL OF THE EGYPTIAN NATIONAL CANCER INSTITUTE, 2012, 24 (04) : 169 - 173
  • [30] Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
    Kinhikar, Rajesh Ashok
    Ghadi, Yogesh G.
    Sahoo, Priyadarshini
    Laskar, Sarbani Ghosh
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    Agarwal, Jaiprakash
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (04) : 190 - 197