Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy

被引:7
|
作者
Kinhikar, Rajesh Ashok [1 ]
Ghadi, Yogesh G. [1 ]
Sahoo, Priyadarshini [1 ]
Laskar, Sarbani Ghosh [2 ]
Deshpande, Deepak D. [1 ]
Shrivastava, Shyam K. [2 ]
Agarwal, Jaiprakash [2 ]
机构
[1] Tata Mem Hosp, Dept Med Phys, Mumbai 400012, Maharashtra, India
[2] Tata Mem Hosp, Dept Radiat Oncol, Mumbai 400012, Maharashtra, India
关键词
Helical tomotherapy; intensity modulated radiotherapy; lung stereotactic body radiotherapy; three-dimensional conformal radiation therapy; treatment planning;
D O I
10.4103/0971-6203.170792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D2cmwas found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [1] Dosimetric Comparisons of Three-dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy in Whole Abdominopelvic Radiotherapy for Gynecologic Malignancy
    Kim, Yong Bae
    Kim, Joo Ho
    Jeong, Kyung Keun
    Seong, Jinsil
    Suh, Chang Ok
    Kim, Gwi Eon
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2009, 8 (05) : 369 - 377
  • [2] Dosimetric comparison of postoperative whole pelvic radiotherapy for endometrial cancer using three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy
    Yang, Ruijie
    Xu, Shouping
    Jiang, Weijuan
    Wang, Junjie
    Xie, Chuanbin
    [J]. ACTA ONCOLOGICA, 2010, 49 (02) : 230 - 236
  • [3] Integral Dose in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Xie, C.
    Wang, J.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (09) : 706 - 712
  • [4] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    [J]. PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [5] Integral Dose Variation in Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Wang, J.
    Xu, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Integral Dose Variation in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Zhou, G.
    Wang, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S713 - S713
  • [7] A dosimetric comparison of intensity modulated radiotherapy versus three-dimensional conformal radiotherapy for esophageal carcinoma
    Jiang, Z.
    Zhou, L.
    Jiang, G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S268 - S268
  • [8] Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules
    Yadav, Poonam
    Yan, Yue
    Ignatowski, Tasha
    Olson, Anna
    [J]. MEDICAL DOSIMETRY, 2017, 42 (01) : 42 - 46
  • [9] Dosimetric analysis of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy-step and shoot, helical tomotherapy, and volumetric modulated arc therapy in prostate cancer radiotherapy
    Gozal, Fenny
    Gondhowiardjo, Soehartati Argadikoesoema
    Kodrat, Henry
    Wibowo, Wahyu Edy
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 893 - 900
  • [10] Dosimetric comparison of intensity-modulated radiotherapy and three-dimensional conformal radiotherapy for cerebral malignant gliomas
    Zheng, Ruifeng
    Fan, Ruitai
    Wen, Haiying
    Luo, Junbo
    Yang, Yang
    [J]. JOURNAL OF BUON, 2015, 20 (01): : 248 - 252