Dosimetric Comparisons of Three-dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy in Whole Abdominopelvic Radiotherapy for Gynecologic Malignancy

被引:11
|
作者
Kim, Yong Bae [1 ]
Kim, Joo Ho [1 ]
Jeong, Kyung Keun [1 ]
Seong, Jinsil [1 ]
Suh, Chang Ok [1 ]
Kim, Gwi Eon [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiat Oncol, Yonsei Canc Ctr,Brain Korea Project Med Sci 21, Seoul, South Korea
关键词
Helical tomotherapy; Whole abdominopelvic radiotherapy; Gynecologic cancer; Bone marrow; EPITHELIAL OVARIAN-CARCINOMA; ACUTE HEMATOLOGIC TOXICITY; RADIATION-THERAPY; ABDOMINAL RADIOTHERAPY; EXTENDED-FIELD; STAGE-I; ABDOMEN IRRADIATION; PLUS CYCLOPHOSPHAMIDE; CONCURRENT CISPLATIN; CERVICAL-CANCER;
D O I
10.1177/153303460900800507
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives. The goal of this study was to dosimetrically compare 3-dimensional radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and helical tomotherapy (TOMO) plans for whole abdominopelvic radiotherapy (WART) in patients with gynecologic cancer. Methods. Ten patients were selected for WART planning. Doses were prescribed to planning target volumes (PTVs) as the followings: 30 Gy to PTV-whole abdominopelvis (PTV-WA), 40 Gy to PTV-para-aortic lymph node (PTV-PALN), 44 Gy to PTV-pelvis, and 50 Gy to gross target volume (GTV) in 20 fractions. Dose to whole liver, both kidneys, and spinal cord were constrained below each tissue tolerance, and bone marrow (BM)-sparing technique was adopted in IMRT and TOMO. Dosimetric parameters and treatment times were compared among plans. Results. Calculated doses in TOMO came most closely to the prescribed dose for coverage of PTV-WA, PTV-PALN, PTV-pelvis, and GTV compared to 3DCRT, and IMRT. In normal organs, TOMO had significantly better dosimetric profiles compared to IMRT and 3DCRT. TOMO significantly reduced V-20Gy, and mean dose of whole liver, both kidneys, and spinal cord. The use of BM-sparing technique (BMS) did not impair coverage of target volume in IMRT and TOMO. While IMRT showed no differences of irradiated BM dose using BMS, TOMO with BMS reduced half V-20Gy of BM compared to TOMO without BMS, Conclusions. TOMO showed dosimetric superiority in target coverage, sparing BM, and other normal organs compared to 3DCRT and IMRT. Clinical experiences will be needed for evaluation of feasibility of WART using TOMO in patients with gynecologic cancer.
引用
收藏
页码:369 / 377
页数:9
相关论文
共 50 条
  • [1] Dosimetric comparison of postoperative whole pelvic radiotherapy for endometrial cancer using three-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and helical tomotherapy
    Yang, Ruijie
    Xu, Shouping
    Jiang, Weijuan
    Wang, Junjie
    Xie, Chuanbin
    [J]. ACTA ONCOLOGICA, 2010, 49 (02) : 230 - 236
  • [2] Integral Dose in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Xie, C.
    Wang, J.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (09) : 706 - 712
  • [3] Integral Dose Variation in Three-dimensional Conformal Radiotherapy, Intensity-modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Xu, S.
    Jiang, W.
    Zhou, G.
    Wang, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S713 - S713
  • [4] Integral Dose Variation in Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, and Helical Tomotherapy
    Yang, R.
    Wang, J.
    Xu, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
    Kinhikar, Rajesh Ashok
    Ghadi, Yogesh G.
    Sahoo, Priyadarshini
    Laskar, Sarbani Ghosh
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    Agarwal, Jaiprakash
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (04) : 190 - 197
  • [6] Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules
    Yadav, Poonam
    Yan, Yue
    Ignatowski, Tasha
    Olson, Anna
    [J]. MEDICAL DOSIMETRY, 2017, 42 (01) : 42 - 46
  • [7] Dosimetric analysis of three-dimensional conformal radiotherapy, intensity-modulated radiotherapy-step and shoot, helical tomotherapy, and volumetric modulated arc therapy in prostate cancer radiotherapy
    Gozal, Fenny
    Gondhowiardjo, Soehartati Argadikoesoema
    Kodrat, Henry
    Wibowo, Wahyu Edy
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (04) : 893 - 900
  • [8] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [9] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    [J]. Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [10] Intensity-modulated three-dimensional conformal radiotherapy
    Mohan, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 121 - 121