A dosimetric phantom study of thoracic radiotherapy based on three-dimensional modeling of mediastinal lymph nodes

被引:2
|
作者
Zhang, Ji-Bin [1 ]
Zhao, Li-Rong [1 ]
Cui, Tian-Xiang [1 ]
Chen, Xie-Wan [2 ]
Yang, Qiao [1 ]
Zhou, Yi-Bing [1 ]
Chen, Zheng-Tang [1 ]
Zhang, Shao-Xiang [3 ]
Sun, Jian-Guo [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Canc Inst, Peoples Liberat Army, 83 Xinqiao St, Chongqing 400037, Peoples R China
[2] Third Mil Med Univ, Coll Basic Med, Dept Med English, Chongqing 400038, Peoples R China
[3] Third Mil Med Univ, Coll Basic Med, Dept Digital Med, Chongqing 400038, Peoples R China
基金
中国国家自然科学基金;
关键词
mediastinal lymph nodes; three-dimensional reconstruction; radiation phantom; plan optimization; dosimetric measurement; thoracic radiotherapy; CELL LUNG-CANCER; HELICAL TOMOTHERAPY; RADIATION-THERAPY; TISSUE; IMRT; VMAT; VERIFICATION; BENEFITS; SYSTEM; ORGANS;
D O I
10.3892/ol.2018.8084
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to investigate the optimal strategy and dosimetric measurement of thoracic radiotherapy based on three-dimensional (3D) modeling of mediastinal lymph nodes (MLNs). A 3D model of MLNs was constructed from a Chinese Visible Human female dataset. Image registration and fusion between reconstructed MLNs and original chest computed tomography (CT) images was conducted in the Eclipse T treatment planning system (TPS). There were three plans, including 3D conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT), which were designed based on 10 cases of simulated lung lesions (SLLs) and MLNs. The quality of these plans was evaluated via examining indexes, including conformity index (CI), homogeneity index and clinical target volume (CTV) coverage. Dose-volume histogram analysis was performed on SLL, MLNs and organs at risk (OARs). A Chengdu Dosimetric Phantom (CDP) was then drilled at specific MLNs according to 20 patients with thoracic tumors and of a medium-build. These plans were repeated on fused MLNs and CDP CT images in the Eclipse T TPS. Radiation doses at the SLLs and MLNs of the CDP were measured and compared with calculated doses. The established 3D MLN model demonstrated the spatial location of MLNs and adjacent structures. Precise image registration and fusion were conducted between reconstructed MLNs and the original chest CT or CDP CT images. IMRT demonstrated greater values in CI, CTV coverage and OAR (lungs and spinal cord) protection, compared with 3D-CRT and VMAT (P< 0.05). The deviation between the measured and calculated doses was within +/- 10% at SLL, and at the 2R and 7th MLN stations. In conclusion, the 3D MLN model can benefit plan optimization and dosimetric measurement of thoracic radiotherapy, and when combined with CDP, it may provide a tool for clinical dosimetric monitoring.
引用
收藏
页码:5634 / 5642
页数:9
相关论文
共 50 条
  • [31] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Mina Yu
    Joo Hwan Lee
    Hong Seok Jang
    Dong Min Jeon
    Jae Suk Cheon
    Hyo Chun Lee
    Jong Hoon Lee
    Radiation Oncology, 8
  • [32] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Yu, Mina
    Lee, Joo Hwan
    Jang, Hong Seok
    Jeon, Dong Min
    Cheon, Jae Suk
    Lee, Hyo Chun
    Lee, Jong Hoon
    RADIATION ONCOLOGY, 2013, 8
  • [33] Dosimetric and clinical results of three-dimensional conformal radiotherapy for locally recurrent nasopharyngeal carcinoma
    Zheng, XK
    Ma, J
    Chen, LH
    Xia, YF
    Shi, YS
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (02) : 197 - 203
  • [34] Dosimetric study of three-dimensional static and dynamic SBRT radiotherapy for hepatocellular carcinoma based on 4DCT image deformable registration
    Ma, Changdong
    Duan, Jinghao
    Yu, Shuang
    Ma, Changsheng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 60 - 66
  • [35] Advanced Lung Cancers - Combined Use of Stereotactic Body Radiation Therapy for Primary Tumour and Three-dimensional Radiotherapy for Mediastinal Nodes Versus Standard 3DRT. an Infra Individual Dosimetric Comparison
    Braccini, A. L.
    Bondiau, P. Y.
    Rucka, G.
    Pezard, J.
    Marcie, S.
    Poudenx, M.
    Otto, J.
    Ortholan, C.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S605 - S605
  • [36] Dosimetric aspects of breast radiotherapy with three-dimensional and intensity-modulated radiotherapy helical tomotherapy planning modules
    Yadav, Poonam
    Yan, Yue
    Ignatowski, Tasha
    Olson, Anna
    MEDICAL DOSIMETRY, 2017, 42 (01) : 42 - 46
  • [37] Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
    Erwann Rault
    Thomas Lacornerie
    Hong-Phuong Dang
    Frederik Crop
    Eric Lartigau
    Nick Reynaert
    David Pasquier
    Radiation Oncology, 11
  • [38] Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy
    Rault, Erwann
    Lacornerie, Thomas
    Hong-Phuong Dang
    Crop, Frederik
    Lartigau, Eric
    Reynaert, Nick
    Pasquier, David
    RADIATION ONCOLOGY, 2016, 11
  • [39] Three-dimensional dosimetric verification of spot-scanning proton therapy in a breast-shaped phantom
    Jensen, S. E.
    Valdetaro, L. Barbosa
    Jensen, M. Fuglsang
    Balling, P.
    Skyt, P. Sandegaard
    Petersen, J. Breede Baltzer
    Muren, L. Paul
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S463 - S464
  • [40] Three-dimensional quantitative ultrasound to guide pathologists towards metastatic foci in lymph nodes
    Mamou, Jonathan
    Saegusa-Beecroft, Emi
    Coron, Alain
    Oelze, Michael L.
    Yamaguchi, Tadashi
    Machi, Junji
    Hata, Masaki
    Yanagihara, Eugene
    Laugier, Pascal
    Feleppa, Ernest J.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1114 - 1117