Palliative radiotherapy for thoracic spine metastases: Dosimetric advantage of three-dimensional conformal plans

被引:6
|
作者
Yeo, Seung-Gu [1 ]
机构
[1] Soonchunhyang Univ, Soonchunhyang Univ Hosp, Dept Radiat Oncol, Coll Med, Cheonan 330721, South Korea
关键词
spine; metastases; palliation; three-dimensional conformal radiotherapy; dosimetry; BONE METASTASES; BREAST-CANCER; HEART-DISEASE; LUNG-CANCER; WOMEN; RISK;
D O I
10.3892/ol.2015.3205
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of the present study was to investigate the dosimetric advantages of three-dimensional conformal radiation therapy (3DCRT) for thoracic spine metastases and compare it with conventional two-dimensional (2D) plans. Radiation therapy (RT) planning data of 10 patients with mid-to-low thoracic spine metastases were analyzed. Computed tomography simulation was performed and the planning target volume (PTV), heart, esophagus, lung and spinal cord were contoured. The 3DCRT plan comprised one posteroanterior (PA) field and two posterior oblique fields. The 2D plans used a single PA field or opposed anteroposterior (AP)/PA fields. The prescription dose of radiation was 30 Gy in 10 fractions. All comparisons of the maximum or mean doses to the organs at risk or the PTV, between two of the three RT plans, demonstrated statistically significant differences (P<0.05), with the exception of the mean esophageal doses between the single PA vs. AP/PA (P=0.285) plans. The mean heart doses were 15.0 +/- 3.1 Gy in single PA, 17.3 +/- 4.3 Gy in AP/PA and 8.5 +/- 1.7 Gy using 3DCRT. The median reduction rates using 3DCRT were 38.9% compared with single PA (range, 29.4-58.5%) or 47.5% relative to AP/PA (range, 34.5-67.1%). The mean esophageal doses were 17.9 +/- 2.3 Gy in single PA, 18.2 +/- 2.2 Gy in AP/PA and 15.3 +/- 1.9 Gy in 3DCRT. The median reduction rate using 3DCRT was 12.8% compared with single PA or 15.6% relative to AP/PA. Compared with the single PA or AP/PA 2D plan, 3DCRT reduced the median dose by 13.7 or 1.9% of the maximum spinal cord dose, respectively, and 14.7 or 2.9% of the maximum PTV dose, respectively. The mean lung doses were 2.7 +/- 0.7 Gy in single PA, 2.6 +/- 0.7 Gy in AP/PA and 5.1 +/- 1.0 Gy in 3DCRT. In conclusion, 3DCRT for mid-to-low thoracic spine metastases demonstrated significant dosimetric advantages by reducing the unnecessary irradiation of critical organs, particularly the heart, and by achieving a homogeneous target dose.
引用
收藏
页码:497 / 501
页数:5
相关论文
共 50 条
  • [1] Dosimetric Evaluation of Intensity Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy Treatment Plans for Prostate Cancer
    Adeneye, Samuel
    Akpochafor, Michael
    Habeebu, Muhammad
    Omojola, Akintayo
    Joseph, Adedayo
    Awhariado, John
    Durosinnmi-Etti, Abayomi
    Aweda, Moses
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 104 - 111
  • [2] Dosimetric Comparison of Three-Dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy for Paediatric Neuroblastoma
    Jiang, M.
    PEDIATRIC BLOOD & CANCER, 2016, 63 : S196 - S196
  • [3] Dosimetric comparison and observation of three-dimensional conformal radiotherapy for recurrent nasopharyngeal carcinoma
    Pan, Rongqiang
    Wang, Jingming
    Qi, Feng
    Liu, Ruizhen
    ONCOLOGY LETTERS, 2017, 14 (04) : 4741 - 4745
  • [4] A dosimetric comparison of intensity modulated radiotherapy versus three-dimensional conformal radiotherapy for esophageal carcinoma
    Jiang, Z.
    Zhou, L.
    Jiang, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S268 - S268
  • [5] A dosimetric evaluation of intensity modulated radiotherapy and three-dimensional conformal radiotherapy for prostate cancer in Ghana
    Kyei, Kofi Adesi
    Daniels, Joseph
    Adom, Ameyaw Kwame
    Odonkor, Philip
    Nyantakyi, Andrew Yaw
    Adjabu, Dorothy Ekua
    ECANCERMEDICALSCIENCE, 2024, 18
  • [6] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [7] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [8] Comparative dosimetric evaluation of three-dimensional conformal and stereotactic radiotherapy for treatment of intracranial tumors
    Gupta, Manoj
    Babaiah, M.
    Kumar, M. Dinesh
    Hirapara, Pushpendra H.
    Patidar, Arvind K.
    Walke, Rahul V.
    JOURNAL OF THE EGYPTIAN NATIONAL CANCER INSTITUTE, 2012, 24 (04) : 169 - 173
  • [9] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Mina Yu
    Joo Hwan Lee
    Hong Seok Jang
    Dong Min Jeon
    Jae Suk Cheon
    Hyo Chun Lee
    Jong Hoon Lee
    Radiation Oncology, 8
  • [10] A comparison of dosimetric parameters between tomotherapy and three-dimensional conformal radiotherapy in rectal cancer
    Yu, Mina
    Lee, Joo Hwan
    Jang, Hong Seok
    Jeon, Dong Min
    Cheon, Jae Suk
    Lee, Hyo Chun
    Lee, Jong Hoon
    RADIATION ONCOLOGY, 2013, 8