Method for simultaneous analysis of eight vitamin E isomers in various foods by high performance liquid chromatography and fluorescence detection

被引:83
|
作者
Pinheiro-Sant'Ana, Helena Maria [1 ]
Guinazi, Michele [1 ]
Oliveira, Daniela da Silva [2 ]
Della Lucia, Ceres Mattos [1 ]
Reis, Barbara de Lazzari [1 ]
Cardoso Brandao, Sebastiao Cesar [2 ]
机构
[1] Univ Fed Vicosa, Dept Nutr & Hlth, Lab Vitamins Anal, BR-36561000 Vicosa, MG, Brazil
[2] Univ Fed Vicosa, Dept Food Technol, BR-36561000 Vicosa, MG, Brazil
关键词
Tocopherols; Tocotrienols; Vegetables; Vegetable oils; Eggs; Seeds; ALPHA-TOCOPHEROL; TOCOTRIENOLS; ANTIOXIDANTS; VEGETABLES; FORMULAS; COLUMNS;
D O I
10.1016/j.chroma.2011.09.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to optimize a method to investigate the occurrence and to quantify the full isomeric composition of vitamin E (alpha-, beta-, gamma- and delta-tocopherols and tocotrienols) in 6 vegetables (raw and cooked). 3 herbs/spices, raw and cooked eggs, vegetable oils (canola, olive and soybean), flaxseed and sorghum (flour and seeds) and soy (flour) by HPLC with fluorescence detection. Different conditions of extraction and analysis were tested. The optimized method consisted of direct extraction with solvent (hexane:ethyl acetate, 85:15, v/v). For analysis normal phase column was used with mobile phase consisting of hexane:isopropanol:acetic acid (98.9:0.6:0.5) with isocratic elution and fluorescence detection. Excellent separation of all isomers was obtained along with adequate quantification in the foods analyzed. Recovery rates of standards ranged from 91.3 to 99.4%. The linearity range for each isomer varied from 2.5 to 137.5 ng/mL (R(2) greater than 0.995 in all cases). Detection limits ranged from 21.0 to 48.0 ng/mL for tocopherols and from 56.0 to 67.0 ng/mL for tocotrienols, while quantification limits ranged from 105.0 to 240.0 ng/mL for tocopherols and from 280.0 to 335.0 ng/mL for tocotrienols. The optimized method was considered simple, fast and reliable, and also preserved vitamin E isomers when compared to validated methods involving saponification. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:8496 / 8502
页数:7
相关论文
共 50 条
  • [41] Simultaneous determination of eight β-blockers by gradient high-performance liquid chromatography with combined ultraviolet and fluorescence detection in corneal permeability studies in vitro
    Ranta, VP
    Toropainen, E
    Talvitie, A
    Auriola, S
    Urtti, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 772 (01): : 81 - 87
  • [42] A SEPARATIVE DETERMINATION OF METHYLGUANIDINE AND AGMATINE IN FOODS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    KAWASAKI, Y
    YAMADA, T
    YOSHIHIRA, K
    TANIMURA, A
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1985, 26 (05): : 483 - 488
  • [43] Trace analysis of endectocides in milk by high performance liquid chromatography with fluorescence detection
    Cerkvenik-Flajs, Vesna
    Milcinski, Luka
    Suessinger, Adica
    Hodoscek, Lena
    Danaher, Martin
    Antonic, Jan
    ANALYTICA CHIMICA ACTA, 2010, 663 (02) : 165 - 171
  • [44] Simultaneous determination of vitamin B, and folic acid by high performance liquid chromatography with post-column chemical derivation and fluorescence detection
    Long, CY
    Gao, YH
    Xu, XM
    Liang, FR
    Liang, CS
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (10) : 1341 - 1344
  • [45] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION FOR THE SIMULTANEOUS DETERMINATION OF VITAMIN-A, VITAMIN-D3 AND VITAMIN-E IN MILK
    ZAMARRENO, MMD
    PEREZ, AS
    PEREZ, CG
    MENDEZ, JH
    JOURNAL OF CHROMATOGRAPHY, 1992, 623 (01): : 69 - 74
  • [46] Determination of isomers of dihydroxybenzenes by high performance liquid chromatography with chemiluminescent detection
    Cui, Hua
    He, Cai-Xia
    Zhao, Gui-Wen
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 2000, 21 (06): : 876 - 878
  • [47] The determination of isomers of dihydroxybenzenes by high performance liquid chromatography with chemiluminescent detection
    Cui, H
    He, CX
    Zhao, GW
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2000, 21 (06): : 876 - 878
  • [48] Simultaneous determination of eight water-soluble vitamins in foods and multivitamin tablets by reversed phase high performance liquid chromatography
    Cheng, ZQ
    Sun, CJ
    Li, YQ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (09) : 1068 - 1071
  • [49] Analysis of eight capsaicinoids in peppers and pepper-containing foods by high-performance liquid chromatography and liquid chromatography-mass spectrometry
    Kozukue, N
    Han, JS
    Kozukue, E
    Lee, SJ
    Kim, JA
    Lee, KR
    Levin, CE
    Friedman, M
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (23) : 9172 - 9181
  • [50] ANALYSIS OF Z-ISOMERS AND E-ISOMERS OF UROCANIC ACID BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MORRISON, H
    AVNIR, D
    ZARRELLA, T
    JOURNAL OF CHROMATOGRAPHY, 1980, 183 (01): : 83 - 86