Method for simultaneous analysis of eight vitamin E isomers in various foods by high performance liquid chromatography and fluorescence detection

被引:83
|
作者
Pinheiro-Sant'Ana, Helena Maria [1 ]
Guinazi, Michele [1 ]
Oliveira, Daniela da Silva [2 ]
Della Lucia, Ceres Mattos [1 ]
Reis, Barbara de Lazzari [1 ]
Cardoso Brandao, Sebastiao Cesar [2 ]
机构
[1] Univ Fed Vicosa, Dept Nutr & Hlth, Lab Vitamins Anal, BR-36561000 Vicosa, MG, Brazil
[2] Univ Fed Vicosa, Dept Food Technol, BR-36561000 Vicosa, MG, Brazil
关键词
Tocopherols; Tocotrienols; Vegetables; Vegetable oils; Eggs; Seeds; ALPHA-TOCOPHEROL; TOCOTRIENOLS; ANTIOXIDANTS; VEGETABLES; FORMULAS; COLUMNS;
D O I
10.1016/j.chroma.2011.09.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to optimize a method to investigate the occurrence and to quantify the full isomeric composition of vitamin E (alpha-, beta-, gamma- and delta-tocopherols and tocotrienols) in 6 vegetables (raw and cooked). 3 herbs/spices, raw and cooked eggs, vegetable oils (canola, olive and soybean), flaxseed and sorghum (flour and seeds) and soy (flour) by HPLC with fluorescence detection. Different conditions of extraction and analysis were tested. The optimized method consisted of direct extraction with solvent (hexane:ethyl acetate, 85:15, v/v). For analysis normal phase column was used with mobile phase consisting of hexane:isopropanol:acetic acid (98.9:0.6:0.5) with isocratic elution and fluorescence detection. Excellent separation of all isomers was obtained along with adequate quantification in the foods analyzed. Recovery rates of standards ranged from 91.3 to 99.4%. The linearity range for each isomer varied from 2.5 to 137.5 ng/mL (R(2) greater than 0.995 in all cases). Detection limits ranged from 21.0 to 48.0 ng/mL for tocopherols and from 56.0 to 67.0 ng/mL for tocotrienols, while quantification limits ranged from 105.0 to 240.0 ng/mL for tocopherols and from 280.0 to 335.0 ng/mL for tocotrienols. The optimized method was considered simple, fast and reliable, and also preserved vitamin E isomers when compared to validated methods involving saponification. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:8496 / 8502
页数:7
相关论文
共 50 条
  • [31] HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY OF VITAMIN-E ISOMERS
    CAVINS, JF
    INGLETT, GE
    CEREAL CHEMISTRY, 1974, 51 (05) : 605 - 609
  • [32] SIMULTANEOUS QUANTITATION OF VITAMIN-A AND VITAMIN-E IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DRISKELL, WJ
    BASHOR, MM
    NEESE, JW
    CLINICAL CHEMISTRY, 1981, 27 (06) : 1031 - 1031
  • [33] Simultaneous analysis of eight components in "Ping-Wei-San" by high performance liquid chromatography
    Lay, HL
    Chen, CC
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (09) : 1439 - 1450
  • [34] SIMULTANEOUS FLUORESCENCE DETERMINATION OF TOTAL ASCORBATE AND TOTAL ERYTHORBATE IN FOODS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HAYASHI, H
    MIYAGAWA, A
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1990, 31 (01): : 44 - 50
  • [35] DETERMINATION OF VITAMIN-A AND VITAMIN-A ACETATE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    COLLINS, CA
    CHOW, CK
    JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC): : 349 - 354
  • [36] Simultaneous determination of seven fluoroquinolones in sewage sludge by high performance liquid chromatography with fluorescence detection
    Chen L.
    Jia C.
    Liu B.
    Jing J.
    Zhao E.
    Yu P.
    He M.
    Earth Science Frontiers, 2019, 26 (06) : 7 - 12
  • [37] SIMULTANEOUS DETERMINATION OF THIOLS AND DISULFIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    OKA, TT
    UCHIYAMA, S
    SAITO, Y
    IMAI, K
    ANALYTICA CHIMICA ACTA, 1988, 205 (1-2) : 29 - 41
  • [38] METHOD FOR ANALYSIS OF DOPAMINE SULFATE ISOMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    ELCHISAK, MA
    CARLSON, JH
    LIFE SCIENCES, 1982, 30 (26) : 2325 - 2336
  • [39] Rapid determination of nitrite in foods in acidic conditions by high-performance liquid chromatography with fluorescence detection
    Wang, Xiao-fang
    Fan, Ji-cai
    Ren, Ren
    Jin, Quan
    Wang, Jing
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (12) : 2263 - 2269
  • [40] SIMULTANEOUS DETERMINATION OF VITAMIN-A AND VITAMIN-E IN FEEDS AND FOODS BY REVERSED PHASE HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    SODERHJELM, P
    ANDERSSON, B
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1978, 29 (08) : 697 - 702