Method for simultaneous analysis of eight vitamin E isomers in various foods by high performance liquid chromatography and fluorescence detection

被引:83
|
作者
Pinheiro-Sant'Ana, Helena Maria [1 ]
Guinazi, Michele [1 ]
Oliveira, Daniela da Silva [2 ]
Della Lucia, Ceres Mattos [1 ]
Reis, Barbara de Lazzari [1 ]
Cardoso Brandao, Sebastiao Cesar [2 ]
机构
[1] Univ Fed Vicosa, Dept Nutr & Hlth, Lab Vitamins Anal, BR-36561000 Vicosa, MG, Brazil
[2] Univ Fed Vicosa, Dept Food Technol, BR-36561000 Vicosa, MG, Brazil
关键词
Tocopherols; Tocotrienols; Vegetables; Vegetable oils; Eggs; Seeds; ALPHA-TOCOPHEROL; TOCOTRIENOLS; ANTIOXIDANTS; VEGETABLES; FORMULAS; COLUMNS;
D O I
10.1016/j.chroma.2011.09.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to optimize a method to investigate the occurrence and to quantify the full isomeric composition of vitamin E (alpha-, beta-, gamma- and delta-tocopherols and tocotrienols) in 6 vegetables (raw and cooked). 3 herbs/spices, raw and cooked eggs, vegetable oils (canola, olive and soybean), flaxseed and sorghum (flour and seeds) and soy (flour) by HPLC with fluorescence detection. Different conditions of extraction and analysis were tested. The optimized method consisted of direct extraction with solvent (hexane:ethyl acetate, 85:15, v/v). For analysis normal phase column was used with mobile phase consisting of hexane:isopropanol:acetic acid (98.9:0.6:0.5) with isocratic elution and fluorescence detection. Excellent separation of all isomers was obtained along with adequate quantification in the foods analyzed. Recovery rates of standards ranged from 91.3 to 99.4%. The linearity range for each isomer varied from 2.5 to 137.5 ng/mL (R(2) greater than 0.995 in all cases). Detection limits ranged from 21.0 to 48.0 ng/mL for tocopherols and from 56.0 to 67.0 ng/mL for tocotrienols, while quantification limits ranged from 105.0 to 240.0 ng/mL for tocopherols and from 280.0 to 335.0 ng/mL for tocotrienols. The optimized method was considered simple, fast and reliable, and also preserved vitamin E isomers when compared to validated methods involving saponification. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:8496 / 8502
页数:7
相关论文
共 50 条
  • [11] Simultaneous analysis of multiple aminothiols in human plasma by high performance liquid chromatography with fluorescence detection
    McMenamin, M. Elizabeth
    Himmelfarb, Jonathan
    Nolin, Thomas D.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (28): : 3274 - 3281
  • [12] Simultaneous analysis of three avermectins in soils by high-performance liquid chromatography with fluorescence detection
    Xie, Xianchuan
    Yao, Fang
    Wu, Yingxin
    Zhao, Li
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (12) : 1417 - 1428
  • [13] Simultaneous determination of lysophospholipids by high-performance liquid chromatography with fluorescence detection
    Servillo, L
    Iorio, EL
    Quagliuolo, L
    Camussi, G
    Balestrieri, C
    Giovane, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 689 (02): : 281 - 286
  • [14] Simultaneous Determination of Six Parabens in Cosmetics by a New High Performance Liquid Chromatography Method with Fluorescence Detection
    Yilmaz, Pelin Koseoglu
    Tokat, Mehmet Akif
    METHODS AND OBJECTS OF CHEMICAL ANALYSIS, 2020, 15 (01): : 27 - 32
  • [15] DETERMINATION OF GLYCEROL IN FOODS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    HAMANO, T
    MITSUHASHI, Y
    AOKI, N
    YAMAMOTO, S
    TSUJI, S
    ITO, Y
    OJI, Y
    JOURNAL OF CHROMATOGRAPHY, 1991, 541 (1-2): : 265 - 272
  • [16] Improved High-Performance Liquid Chromatography Method with Diode Array Detection for Simultaneous Analysis of Retinoic Acid Isomers, Retinol, Retinyl esters, Vitamin E, and Selected Carotenoids in Guinea Pig Tissues
    Schaeffer, Michael W.
    Roy, Somdutta Sinha
    Mukherjee, Shyamali
    Das, Salil K.
    FASEB JOURNAL, 2008, 22
  • [17] High-Performance Liquid Chromatography with Fluorescence Detection for Simultaneous Analysis of Retinoids (Retinyl Palmitate, Retinyl Acetate, and Free Retinol) and α-, β-, γ-, and δ-Tocopherols in Foods
    Mami Ishimaru
    Masato Haraoka
    Hideo Hatate
    Ryusuke Tanaka
    Food Analytical Methods, 2017, 10 : 92 - 99
  • [18] High-Performance Liquid Chromatography with Fluorescence Detection for Simultaneous Analysis of Phytosterols (Stigmasterol, β-Sitosterol, Campesterol, Ergosterol, and Fucosterol) and Cholesterol in Plant Foods
    Meiko Ito
    Mami Ishimaru
    Toshiyuki Shibata
    Hideo Hatate
    Ryusuke Tanaka
    Food Analytical Methods, 2017, 10 : 2692 - 2699
  • [19] High-Performance Liquid Chromatography with Fluorescence Detection for Simultaneous Analysis of Phytosterols (Stigmasterol, β-Sitosterol, Campesterol, Ergosterol, and Fucosterol) and Cholesterol in Plant Foods
    Ito, Meiko
    Ishimaru, Mami
    Shibata, Toshiyuki
    Hatate, Hideo
    Tanaka, Ryusuke
    FOOD ANALYTICAL METHODS, 2017, 10 (08) : 2692 - 2699
  • [20] High-Performance Liquid Chromatography with Fluorescence Detection for Simultaneous Analysis of Retinoids (Retinyl Palmitate, Retinyl Acetate, and Free Retinol) and α-, β-, γ-, and δ-Tocopherols in Foods
    Ishimaru, Mami
    Haraoka, Masato
    Hatate, Hideo
    Tanaka, Ryusuke
    FOOD ANALYTICAL METHODS, 2017, 10 (01) : 92 - 99