Method for simultaneous analysis of eight vitamin E isomers in various foods by high performance liquid chromatography and fluorescence detection

被引:83
|
作者
Pinheiro-Sant'Ana, Helena Maria [1 ]
Guinazi, Michele [1 ]
Oliveira, Daniela da Silva [2 ]
Della Lucia, Ceres Mattos [1 ]
Reis, Barbara de Lazzari [1 ]
Cardoso Brandao, Sebastiao Cesar [2 ]
机构
[1] Univ Fed Vicosa, Dept Nutr & Hlth, Lab Vitamins Anal, BR-36561000 Vicosa, MG, Brazil
[2] Univ Fed Vicosa, Dept Food Technol, BR-36561000 Vicosa, MG, Brazil
关键词
Tocopherols; Tocotrienols; Vegetables; Vegetable oils; Eggs; Seeds; ALPHA-TOCOPHEROL; TOCOTRIENOLS; ANTIOXIDANTS; VEGETABLES; FORMULAS; COLUMNS;
D O I
10.1016/j.chroma.2011.09.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objective of this study was to optimize a method to investigate the occurrence and to quantify the full isomeric composition of vitamin E (alpha-, beta-, gamma- and delta-tocopherols and tocotrienols) in 6 vegetables (raw and cooked). 3 herbs/spices, raw and cooked eggs, vegetable oils (canola, olive and soybean), flaxseed and sorghum (flour and seeds) and soy (flour) by HPLC with fluorescence detection. Different conditions of extraction and analysis were tested. The optimized method consisted of direct extraction with solvent (hexane:ethyl acetate, 85:15, v/v). For analysis normal phase column was used with mobile phase consisting of hexane:isopropanol:acetic acid (98.9:0.6:0.5) with isocratic elution and fluorescence detection. Excellent separation of all isomers was obtained along with adequate quantification in the foods analyzed. Recovery rates of standards ranged from 91.3 to 99.4%. The linearity range for each isomer varied from 2.5 to 137.5 ng/mL (R(2) greater than 0.995 in all cases). Detection limits ranged from 21.0 to 48.0 ng/mL for tocopherols and from 56.0 to 67.0 ng/mL for tocotrienols, while quantification limits ranged from 105.0 to 240.0 ng/mL for tocopherols and from 280.0 to 335.0 ng/mL for tocotrienols. The optimized method was considered simple, fast and reliable, and also preserved vitamin E isomers when compared to validated methods involving saponification. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:8496 / 8502
页数:7
相关论文
共 50 条
  • [21] Pressurized liquid extraction prior to liquid chromatography with electrochemical detection for the analysis of vitamin E isomers in seeds and nuts
    Delgado-Zamarreño, MM
    Bustamante-Rangel, M
    Sánchez-Pérez, A
    Carabias-Martínez, R
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) : 249 - 252
  • [22] SIMULTANEOUS ANALYSIS OF THIAMIN AND RIBOFLAVIN IN FOODS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WIMALASIRI, P
    WILLS, RBH
    JOURNAL OF CHROMATOGRAPHY, 1985, 318 (02): : 412 - 416
  • [23] Simultaneous determination of airborne carbamates in workplace by high performance liquid chromatography with fluorescence detection
    Li, HP
    Li, JH
    Li, GC
    Jen, JF
    TALANTA, 2004, 63 (03) : 547 - 553
  • [24] Simultaneous measurement of phenylalanine and tyrosine by high performance liquid chromatography (HPLC) with fluorescence detection
    Neurauter, Gabriele
    Scholl-Buergi, Sabine
    Haara, Astrid
    Geisler, Simon
    Mayersbach, Peter
    Schennach, Harald
    Fuchs, Dietmar
    CLINICAL BIOCHEMISTRY, 2013, 46 (18) : 1848 - 1851
  • [25] Method for simultaneous analysis of eight analogues of vitamin D using liquid chromatography tandem mass spectrometry
    Shah, Iltaf
    Petroczi, Andrea
    Naughton, Declan P.
    CHEMISTRY CENTRAL JOURNAL, 2012, 6
  • [26] Method for simultaneous analysis of eight analogues of vitamin D using liquid chromatography tandem mass spectrometry
    Iltaf Shah
    Andrea Petroczi
    Declan P Naughton
    Chemistry Central Journal, 6
  • [27] Simultaneous Determination of Eight Preservatives in Feeds by High Performance Liquid Chromatography
    Gao, Wen-Hui
    Cao, Xiao-Mei
    Han, Jun-Hua
    Li, Xing-Feng
    Jia, Ying-Min
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (14) : 4162 - 4166
  • [28] Fast and simultaneous analysis of biothiols by high-performance liquid chromatography with fluorescence detection under hydrophilic interaction chromatography conditions
    Isokawa, Muneki
    Funatsu, Takashi
    Tsunoda, Makoto
    ANALYST, 2013, 138 (13) : 3802 - 3808
  • [29] Optimization and development of a high-performance liquid chromatography method for the simultaneous determination of vitamin E and carotenoids in tomato fruits
    Irakli, Maria
    Chatzopoulou, Paschalina
    Kadoglidou, Kalliopi
    Tsivelika, Nektaria
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (17) : 3348 - 3356
  • [30] Analysis of vitamin E isomers in seeds and nuts with and without coupled hydrolysis by liquid chromatography and coulometric detection
    Delgado-Zamarreño, MM
    Bustamante-Rangel, M
    Sánchez-Pérez, A
    Hernández-Méndez, J
    JOURNAL OF CHROMATOGRAPHY A, 2001, 935 (1-2) : 77 - 86