Comparison of forward- and back-projection in vivo EPID dosimetry for VMAT treatment of the prostate

被引:29
|
作者
Bedford, James L. [1 ]
Hanson, Ian M.
Hansen, Vibeke N.
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 02期
关键词
portal dosimetry; EPID; VMAT; treatment plan; MODULATED ARC THERAPY; DOSE VERIFICATION; PORTAL DOSIMETRY; STATISTICS NOTES; RADIOTHERAPY; IMRT; IMPLEMENTATION; OPTIMIZATION; IMAGES; MODE;
D O I
10.1088/1361-6560/aa9c60
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the forward-projection method of portal dosimetry for volumetric modulated arc therapy (VMAT), the integrated signal at the electronic portal imaging device (EPID) is predicted at the time of treatment planning, against which the measured integrated image is compared. In the back-projection method, the measured signal at each gantry angle is back-projected through the patient CT scan to give a measure of total dose to the patient. This study aims to investigate the practical agreement between the two types of EPID dosimetry for prostate radiotherapy. The AutoBeam treatment planning system produced VMAT plans together with corresponding predicted portal images, and a total of 46 sets of gantry-resolved portal images were acquired in 13 patients using an iViewGT portal imager. For the forward-projection method, each acquisition of gantry-resolved images was combined into a single integrated image and compared with the predicted image. For the back-projection method, iViewDose was used to calculate the dose distribution in the patient for comparison with the planned dose. A gamma index for 3% and 3 mm was used for both methods. The results were investigated by delivering the same plans to a phantom and repeating some of the deliveries with deliberately introduced errors. The strongest agreement between forward-and back-projection methods is seen in the isocentric intensity/dose difference, with moderate agreement in the mean gamma. The strongest correlation is observed within a given patient, with less correlation between patients, the latter representing the accuracy of prediction of the two methods. The error study shows that each of the two methods has its own distinct sensitivity to errors, but that overall the response is similar. The forward-and back-projection EPID dosimetry methods show moderate agreement in this series of prostate VMAT patients, indicating that both methods can contribute to the verification of dose delivered to the patient.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Clinical pilot study for EPID-based in vivo dosimetry using EPIgray™ for head and neck VMAT
    Halliday, Sophie D.
    Day, Rebecca A.
    Greig, Lynne
    Louwe, Robert J. W.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (04) : 1335 - 1340
  • [32] EPID-BASED IN VIVO DOSIMETRY SYSTEM FOR SBRT-VMAT: MEASURED VERSUS PLANNED DOSE
    McCowan, Peter M.
    van Beek, Timothy
    vanUytven, Eric
    Butler, Jim
    Loewen, Shaun K.
    Nashed, Maged
    Quon, Harvey
    McCurdy, Boyd
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S2 - S3
  • [33] Accuracy of portal dosimetry in hybrid IMRT and VMAT treatment of the prostate
    Bedford, J.
    Hanson, I.
    Smyth, G.
    Tree, A.
    Dearnaley, D.
    Hansen, V. N.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S7 - S8
  • [34] Towards Portal Dosimetry for the MR-linac: back-projection algorithm in the presence of MRI scanner
    Xirau, I. Torres
    Rozendaal, R.
    Olaciregui-Ruiz, I.
    Gonzalez, P.
    Van der Heide, U.
    Sonke, J. J.
    Mans, A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S261 - S261
  • [35] On the computational implementation of forward and back-projection operations for cone-beam computed tomography
    Davood Karimi
    Rabab Ward
    Medical & Biological Engineering & Computing, 2016, 54 : 1193 - 1204
  • [36] Comparison between Filtered Back-Projection and Spline and Chebyshev Reconstruction Techniques
    Kastis, G. A.
    Samartzis, A.
    Fokas, A. S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S221 - S221
  • [37] On the computational implementation of forward and back-projection operations for cone-beam computed tomography
    Karimi, Davood
    Ward, Rabab
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (08) : 1193 - 1204
  • [38] Pre-treatment and in vivo EPID dosimetry for head and neck cancer
    McDermott, L.
    Wendling, M.
    Sonke, J.
    van Herk, M.
    Mijnheer, B.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S307 - S307
  • [39] In-vivo EPID dosimetry for IMRT and VMAT based on through-air predicted portal dose algorithm
    Najem, M. A.
    Tedder, M.
    King, D.
    Bernstein, D.
    Trouncer, R.
    Meehan, C.
    Bidmead, A. M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 : 143 - 153
  • [40] 3d in vivo dosimetry of IMRT treatments of prostate cancer using an epid
    Wendling, M.
    McDermott, L. N.
    Sonke, J-J.
    van Herk, M.
    Mijnheer, B. J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S159 - S159