Comparison of forward- and back-projection in vivo EPID dosimetry for VMAT treatment of the prostate

被引:29
|
作者
Bedford, James L. [1 ]
Hanson, Ian M.
Hansen, Vibeke N.
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 02期
关键词
portal dosimetry; EPID; VMAT; treatment plan; MODULATED ARC THERAPY; DOSE VERIFICATION; PORTAL DOSIMETRY; STATISTICS NOTES; RADIOTHERAPY; IMRT; IMPLEMENTATION; OPTIMIZATION; IMAGES; MODE;
D O I
10.1088/1361-6560/aa9c60
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the forward-projection method of portal dosimetry for volumetric modulated arc therapy (VMAT), the integrated signal at the electronic portal imaging device (EPID) is predicted at the time of treatment planning, against which the measured integrated image is compared. In the back-projection method, the measured signal at each gantry angle is back-projected through the patient CT scan to give a measure of total dose to the patient. This study aims to investigate the practical agreement between the two types of EPID dosimetry for prostate radiotherapy. The AutoBeam treatment planning system produced VMAT plans together with corresponding predicted portal images, and a total of 46 sets of gantry-resolved portal images were acquired in 13 patients using an iViewGT portal imager. For the forward-projection method, each acquisition of gantry-resolved images was combined into a single integrated image and compared with the predicted image. For the back-projection method, iViewDose was used to calculate the dose distribution in the patient for comparison with the planned dose. A gamma index for 3% and 3 mm was used for both methods. The results were investigated by delivering the same plans to a phantom and repeating some of the deliveries with deliberately introduced errors. The strongest agreement between forward-and back-projection methods is seen in the isocentric intensity/dose difference, with moderate agreement in the mean gamma. The strongest correlation is observed within a given patient, with less correlation between patients, the latter representing the accuracy of prediction of the two methods. The error study shows that each of the two methods has its own distinct sensitivity to errors, but that overall the response is similar. The forward-and back-projection EPID dosimetry methods show moderate agreement in this series of prostate VMAT patients, indicating that both methods can contribute to the verification of dose delivered to the patient.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Three-Dimensional Dose Reconstruction in the Presence of Inhomogeneities Using Fast EPID-Based Back-Projection Method
    Ren, Q.
    Cao, R.
    Pei, X.
    Wang, H.
    Hu, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3193 - 3193
  • [42] Radon-transformation and filtered back-projection - a way to fast Ad-hoc VMAT-adaptation?
    Bratengeier, K.
    Kirschbaum, K.
    Hahn, B.
    Paulus, P.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1573 - S1575
  • [43] 3D EPID based dosimetry for pre-treatment verification of VMAT - methods and challenges
    Greer, P. B.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [44] Comparison of filtered back-projection and iterative reconstruction of dopamine transporter SPECT studies
    Koerber, C.
    Koerber-Hafner, N.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S258 - S258
  • [45] Comparison of SIMO-Based Wavenumber Domain and Back-Projection Imaging Algorithms
    Liu, Shuang
    Li, Shiyong
    Zhao, Guoqiang
    Sun, Houjun
    2015 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), VOLS 1-3, 2015,
  • [46] A Comparison Study on Ray-driven Approximation in Re-projection and Back-projection for CT Reconstruction
    Fan, Yi
    Lu, Hongbing
    Ma, Jianhua
    Zhu, Hongbin
    Liu, Yan
    Liang, Zhengrong
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4201 - 4205
  • [47] Detection of Treatment Variability Using Universal Metrics in EPID In-Vivo Dosimetry
    Hernandez, D.
    Dieterich, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E353 - E353
  • [48] Evaluation of EPID based transit dosimetry on the implementation of In-vivo dosimetry and a step forward for dose guided adaptive radiation therapy
    Wilson, D.
    Sankar, A.
    Warnock, J.
    Goodall, L.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S226 - S226
  • [49] Initial clinical experience with Epid-based in-vivo dosimetry for VMAT treatments of head-and-neck tumors
    Cilla, Savino
    Meluccio, Daniela
    Fidanzio, Andrea
    Azario, Luigi
    Ianiro, Anna
    Macchia, Gabriella
    Digesu, Cinzia
    Deodato, Francesco
    Valentini, Vincenzo
    Morganti, Alessio G.
    Piermattei, Angelo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (01): : 52 - 58
  • [50] Impact of daily anatomical changes on EPID-based in vivo dosimetry of VMAT treatments of head-and-neck cancer
    Rozendaal, Roel A.
    Mijnheer, Ben J.
    Hamming-Vrieze, Olga
    Mans, Anton
    van Herk, Marcel
    RADIOTHERAPY AND ONCOLOGY, 2015, 116 (01) : 70 - 74