In-vivo EPID dosimetry for IMRT and VMAT based on through-air predicted portal dose algorithm

被引:5
|
作者
Najem, M. A. [1 ,2 ]
Tedder, M. [3 ]
King, D. [1 ,2 ]
Bernstein, D. [1 ,2 ]
Trouncer, R. [1 ,2 ]
Meehan, C. [1 ,2 ]
Bidmead, A. M. [1 ,2 ]
机构
[1] Royal Marsden NHS Fdn Trust, Joint Dept Phys, Fulham Rd, London SW3 6JJ, England
[2] Inst Canc Res, Fulham Rd, London SW3 6JJ, England
[3] Guys & St Thomas NHS Fdn Trust, Med Phys Dept, London SE1 7EH, England
关键词
INITIAL CLINICAL-EXPERIENCE; PRETREATMENT VERIFICATION; CONFORMAL RADIOTHERAPY; TRANSIT DOSIMETRY; PROSTATE-CANCER; TRIAL; HEAD; NECK;
D O I
10.1016/j.ejmp.2018.07.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have adapted the methodology of Berry et al. (2012) for Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) treatments at a fixed source to imager distance (SID) based on the manufacturer's through-air portal dose image prediction algorithm. In order to fix the SID a correction factor was introduced to account for the change in air gap between patient and imager. Commissioning data, collected with multiple field sizes, solid water thicknesses and air gaps, were acquired at 150 cm SID on the Varian aS1200 EPID. The method was verified using six IMRT and seven VMAT plans on up to three different phantoms. The method's sensitivity and accuracy were investigated by introducing errors. A global 3%/3 mm gamma was used to assess the differences between the predicted and measured portal dose images. The effect of a varying air gap on EPID signal was found to be significant - varying by up to 30% with field size, phantom thickness, and air gap. All IMRT plans passed the 3%/3mm gamma criteria by more than 95% on the three phantoms. 23 of 24 arcs from the VMAT plans passed the 3%/3mm gamma criteria by more than 95%. This method was found to be sensitive to a range of potential errors. The presented approach provides fast and accurate in-vivo EPID dosimetry for IMRT and VMAT treatments and can potentially replace many pre-treatment verifications.
引用
收藏
页码:143 / 153
页数:11
相关论文
共 50 条
  • [1] Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm
    Berry, Sean L.
    Sheu, Ren-Dih
    Polvorosa, Cynthia S.
    Wuu, Cheng-Shie
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 87 - 98
  • [2] Three-dimensional in-vivo EPID dosimetry of IMRT and VMAT treatments
    Van Uytven, E.
    Van Beek, T.
    Chytyk, K.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4634 - 4634
  • [3] 3D EPID-based in vivo dosimetry for IMRT and VMAT
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Vijlbrief, R.
    Mans, A.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [4] VMAT Case Study for Patient Specific Virtual Compensator Algorithm EPID In-Vivo Dosimetry
    Barbiere, J.
    Forbang, R. Teboh
    Ndlovu, A.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E672 - E672
  • [5] Characterization of a new EPID-based system for in-vivo dosimetry in VMAT treatments
    Bresciani, S.
    Poli, M.
    Miranti, A.
    Maggio, A.
    Di Dia, A.
    Bracco, C.
    Stasi, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S736 - S737
  • [6] Clinical results of an EPID-based in-vivo dosimetry for prostate cancer treated by VMAT
    Falco, M. D.
    Giancaterino, S.
    De Nicola, A.
    Perrotti, F.
    Menna, S.
    Fidanzio, A.
    Piermattei, A.
    Genovesi, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S706 - S706
  • [7] Initial clinical experience with EPID-based in-vivo dosimetry for VMAT treatment verification
    Cilla, S.
    Meluccio, D.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Deodato, F.
    Macchia, G.
    Digesu, C.
    Valentini, V.
    Morganti, A. G.
    Piermattei, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S852 - S852
  • [8] Epid-based in vivo dosimetry for SBRT-VMAT treatment dose verification
    Cilla, S.
    Ianiro, A.
    Craus, M.
    Viola, P.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Grusio, M.
    Deodato, F.
    Macchia, G.
    Valentini, V.
    Morganti, A.
    Piermattei, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S772 - S773
  • [9] Sensing ability of EPID-based in vivo dosimetry for VMAT
    Tanooka, M.
    Tarutani, K.
    Doi, H.
    Suzuki, H.
    Takada, Y.
    Fujiwara, M.
    Toda, Y.
    Fujimoto, H.
    Miyashita, M.
    Okumura, A.
    Kagawa, K.
    Kamikonya, N.
    Yamakado, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S939 - S940
  • [10] A novel method for sub-arc VMAT dose delivery verification based on portal dosimetry with an EPID
    Cools, Ruud A. M.
    Dirkx, Maarten L. P.
    Heijmen, Ben J. M.
    [J]. MEDICAL PHYSICS, 2017, 44 (11) : 5556 - 5562