Epid-based in vivo dosimetry for SBRT-VMAT treatment dose verification

被引:0
|
作者
Cilla, S. [1 ]
Ianiro, A. [1 ]
Craus, M. [1 ]
Viola, P. [1 ]
Fidanzio, A. [2 ]
Azario, L. [2 ]
Greco, F. [2 ]
Grusio, M. [2 ]
Deodato, F. [3 ]
Macchia, G. [3 ]
Valentini, V. [4 ]
Morganti, A. [5 ]
Piermattei, A. [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Fdn Ric & Cura Giovanni Paolo II, Med Phys Unit, Campobasso, Italy
[2] Univ Cattolica Sacro Cuore, Policlin Univ A Gemelli, Med Phys Dept, Rome, Italy
[3] Univ Cattolica Sacro Cuore, Fdn Ric & Cura Giovanni Paolo II, Radiat Oncol Unit, Campobasso, Italy
[4] Univ Cattolica Sacro Cuore, Policlin Univ A Gemelli, Radiat Oncol Dept, Rome, Italy
[5] Univ Bologna, Radiat Oncol Ctr, Dept Expt Diagnost & Specialty Med DIMES, Bologna, Italy
关键词
D O I
10.1016/S0167-8140(17)31883-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1448
引用
收藏
页码:S772 / S773
页数:2
相关论文
共 50 条
  • [1] EPID-BASED IN VIVO DOSIMETRY SYSTEM FOR SBRT-VMAT: MEASURED VERSUS PLANNED DOSE
    McCowan, Peter M.
    van Beek, Timothy
    vanUytven, Eric
    Butler, Jim
    Loewen, Shaun K.
    Nashed, Maged
    Quon, Harvey
    McCurdy, Boyd
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S2 - S3
  • [2] An in vivo dose verification method for SBRT-VMAT delivery using the EPID
    McCowan, P. M.
    Van Uytven, E.
    Van Beek, T.
    Asuni, G.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2015, 42 (12) : 6955 - 6963
  • [3] An EPID-based 3D patient dose verification method for SBRT-VMAT delivery
    McCowan, P.
    vanUytven, E.
    vanBeek, T.
    McCurdy, B.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 2 - 2
  • [4] Initial clinical experience with EPID-based in-vivo dosimetry for VMAT treatment verification
    Cilla, S.
    Meluccio, D.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Deodato, F.
    Macchia, G.
    Digesu, C.
    Valentini, V.
    Morganti, A. G.
    Piermattei, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S852 - S852
  • [5] Sensing ability of EPID-based in vivo dosimetry for VMAT
    Tanooka, M.
    Tarutani, K.
    Doi, H.
    Suzuki, H.
    Takada, Y.
    Fujiwara, M.
    Toda, Y.
    Fujimoto, H.
    Miyashita, M.
    Okumura, A.
    Kagawa, K.
    Kamikonya, N.
    Yamakado, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S939 - S940
  • [6] In-vivo dose verification of SBRT-VMAT treatment delivery using transmission EPID images with 4DCT datasets
    Aftabi, Sajjad
    Venkataraman, Sankaranarayanan
    VanBeek, Timothy
    McGeachy, Philip
    McCowan, Peter
    Pistorius, Stephen
    McCurdy, Boyd
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4380 - 4380
  • [7] Clinical Implementation Of EPID-based Daily In Vivo Dose Verification System For SBRT Patients
    Asuni, G.
    vanBeek, T.
    McCowan, P.
    VanUytven, E.
    McCurdy, B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S19 - S19
  • [8] 3D EPID-based in vivo dosimetry for IMRT and VMAT
    Mijnheer, B.
    Olaciregui-Ruiz, I.
    Rozendaal, R.
    Sonke, J-J
    Spreeuw, H.
    Tielenburg, R.
    van Herk, M.
    Vijlbrief, R.
    Mans, A.
    [J]. 7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [9] EPID-Based 4D Patient Dose Verification for Lung SBRT Treatment
    Lin, M.
    Li, J.
    Wang, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Characterization of a new EPID-based system for in-vivo dosimetry in VMAT treatments
    Bresciani, S.
    Poli, M.
    Miranti, A.
    Maggio, A.
    Di Dia, A.
    Bracco, C.
    Stasi, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S736 - S737