In-vivo dose verification of SBRT-VMAT treatment delivery using transmission EPID images with 4DCT datasets

被引:0
|
作者
Aftabi, Sajjad [1 ]
Venkataraman, Sankaranarayanan [1 ]
VanBeek, Timothy [1 ]
McGeachy, Philip [1 ]
McCowan, Peter [1 ]
Pistorius, Stephen [1 ]
McCurdy, Boyd [1 ]
机构
[1] Univ Manitoba, CancerCare Manitoba, Winnipeg, MB, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
33
引用
收藏
页码:4380 / 4380
页数:1
相关论文
共 34 条
  • [1] An in vivo dose verification method for SBRT-VMAT delivery using the EPID
    McCowan, P. M.
    Van Uytven, E.
    Van Beek, T.
    Asuni, G.
    McCurdy, B. M. C.
    [J]. MEDICAL PHYSICS, 2015, 42 (12) : 6955 - 6963
  • [2] Epid-based in vivo dosimetry for SBRT-VMAT treatment dose verification
    Cilla, S.
    Ianiro, A.
    Craus, M.
    Viola, P.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Grusio, M.
    Deodato, F.
    Macchia, G.
    Valentini, V.
    Morganti, A.
    Piermattei, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S772 - S773
  • [3] An EPID-based 3D patient dose verification method for SBRT-VMAT delivery
    McCowan, P.
    vanUytven, E.
    vanBeek, T.
    McCurdy, B.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 2 - 2
  • [4] EPID-BASED IN VIVO DOSIMETRY SYSTEM FOR SBRT-VMAT: MEASURED VERSUS PLANNED DOSE
    McCowan, Peter M.
    van Beek, Timothy
    vanUytven, Eric
    Butler, Jim
    Loewen, Shaun K.
    Nashed, Maged
    Quon, Harvey
    McCurdy, Boyd
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S2 - S3
  • [5] Sensitivity of ASi EPID to Delivery Errors for Pre Treatment Verification of Lung SBRT VMAT Plans
    Alharthi, T.
    Arumugam, S.
    Vial, P.
    Holloway, L.
    Thwaites, D.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E324 - E324
  • [6] EPID sensitivity to delivery errors for pre-treatment verification of lung SBRT VMAT plans
    Alharthi, Thahabah
    Arumugam, Sankar
    Vial, Phil
    Holloway, Lois
    Thwaites, David
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 59 : 37 - 46
  • [7] Initial clinical experience with EPID-based in-vivo dosimetry for VMAT treatment verification
    Cilla, S.
    Meluccio, D.
    Fidanzio, A.
    Azario, L.
    Greco, F.
    Deodato, F.
    Macchia, G.
    Digesu, C.
    Valentini, V.
    Morganti, A. G.
    Piermattei, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S852 - S852
  • [8] A multicentre QA study on 4DCT and IMRT/VMAT techniques for lung SBRT using a respiratory phantom
    Lambrecht, M.
    Sonke, J. J.
    Verheij, M.
    Hurkmans, C. W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S286 - S287
  • [9] In Vivo Treatment Verification using EPID Transit Dose Images Created from Thru-Air Portal Dose Images
    Berry, S. L.
    Sheu, R.
    Polvorosa, C.
    Wuu, C. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S823 - S824
  • [10] Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing
    Ding, A.
    Han, B.
    Bush, K.
    Wang, L.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3447 - 3447