Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis

被引:16
|
作者
Bouza, Marcos [1 ]
Pereiro, Rosario [1 ]
Bordel, Nerea [2 ]
Sanz-Medel, Alfredo [1 ]
Fernandez, Beatriz [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Univ Oviedo, Dept Phys, E-33006 Oviedo, Spain
关键词
DEPTH-PROFILE ANALYSIS;
D O I
10.1039/c4ja00474d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical potential of radiofrequency pulsed glow discharge time of flight mass spectrometry (rf-PGD-ToFMS) is investigated for quantitative depth profiling analysis of glasses and thin conductive and non-conductive layers on glasses. PGD in combination with ToFMS can allow the reduction or even removal of spectral interferences by selecting a proper GD pulse interval. Thus, discrimination of potential polyatomic interferences for several analytes (e.g., Si-28(+), K-39(+), Ca-44(+), and Ti-48(+)) was investigated by selecting appropriate time positions along the GD pulse profile. In this paper, the determination of compositional depth profiles of coated glasses was performed by resorting to a multi-matrix calibration procedure. For this purpose, conductive as well as non-conductive certified reference materials were employed to build the analytical calibration curves. Results show that rf-PGD-ToFMS allows us to discriminate the different layers of the samples and the nominal values for element concentrations and layer thicknesses were in agreement with experimental results obtained using the proposed quantification strategy. Moreover, the capability of rf-PGD-ToFMS to provide a full mass spectrum every 33 mu s enable the identification of unexpected elements which can be present as contaminants in very thin layers (e.g. Cd, Sn, Te and Sb).
引用
下载
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [1] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    20151900828891
    Fernández, Beatriz (fernandezbeatriz@uniovi.es), 1600, Royal Society of Chemistry (30):
  • [2] Technical note: Characterization of gold coated ceramics by radiofrequency pulsed glow discharge - time of flight mass spectrometry
    Bouza, Marcos
    Lobo, Lara
    Muniz, Rocio
    Pereiro, Rosario
    Esparza, Joseba
    Antonio Garcia, Jose
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (03) : 502 - 507
  • [3] Pulsed radiofrequency glow discharge time of flight mass spectrometer for the direct analysis of bulk and thin coated glasses
    Muniz, A. C.
    Pisonero, J.
    Lobo, L.
    Gonzalez, C.
    Bordel, N.
    Pereiro, R.
    Tempez, A.
    Chapon, P.
    Tuccitto, N.
    Licciardello, A.
    Sanz-Medel, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1239 - 1246
  • [4] Pulsed radiofrequency glow discharge time of flight mass spectrometer for the direct analysis of bulk and thin coated glasses
    Muñiz, A.C.
    Pisonero, J.
    Lobo, L.
    Gonzalez, C.
    Bordel, N.
    Pereiro, R.
    Tempez, A.
    Chapon, P.
    Tuccitto, N.
    Licciardello, A.
    Sanz-Medel, A.
    Journal of Analytical Atomic Spectrometry, 2008, 23 (09): : 1239 - 1246
  • [5] Pulsed Radiofrequency Glow Discharge Time-of-Flight Mass Spectrometry for Nanostructured Materials Characterization
    Bustelo, Marta
    Fernandez, Beatriz
    Pisonero, Jorge
    Pereiro, Rosario
    Bordel, Nerea
    Vega, Victor
    Prida, Victor M.
    Sanz-Medel, Alfredo
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 329 - 337
  • [6] An ion source for radiofrequency-pulsed glow discharge time-of-flight mass spectrometry
    Gonzalez Gago, C.
    Lobo, L.
    Pisonero, J.
    Bordel, N.
    Pereiro, R.
    Sanz-Medel, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 159 - 165
  • [7] Investigation of the afterglow time regime in pulsed radiofrequency glow discharge time-of-flight mass spectrometry
    Gonzales Gago, C.
    Bordel, N.
    Pereiro, R.
    Sanz-Medel, A.
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (08): : 757 - 763
  • [8] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [9] Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis
    Sola-Vazquez, Auristela
    Fernandez, Beatriz
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7431 - 7443
  • [10] Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis
    Auristela Solà-Vázquez
    Beatriz Fernández
    José M. Costa-Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2014, 406 : 7431 - 7443