Pulsed radiofrequency glow discharge time of flight mass spectrometer for the direct analysis of bulk and thin coated glasses

被引:50
|
作者
Muniz, A. C. [1 ]
Pisonero, J. [1 ]
Lobo, L. [2 ]
Gonzalez, C. [1 ]
Bordel, N. [1 ]
Pereiro, R. [2 ]
Tempez, A. [3 ]
Chapon, P. [3 ]
Tuccitto, N. [4 ]
Licciardello, A. [4 ]
Sanz-Medel, A. [2 ]
机构
[1] Univ Oviedo, Fac Sci, Dept Phys, Oviedo 33007, Spain
[2] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[3] Horiba Jobin Yvon, F-91160 Longjumeau, France
[4] Univ Catania, Dipartimento Sci Chim, I-95125 Catania, Italy
关键词
D O I
10.1039/b804169p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct solid analysis of bulk and thin coated glasses by pulsed radiofrequency (rf) glow discharge time-of-flight mass spectrometry (GD-TOFMS) is investigated. Modulated low pressure plasma created by pulsed-rf-GD has been coupled to a fast TOFMS in order to obtain complete mass spectra information from the different GD pulse domains (pre-peak, plateau and afterglow). In particular, it was observed that the analytes show the highest atomic ion signals in the afterglow region some hundred microseconds after the maximum of the Ar ion signal. However, it should be highlighted that the analyte ions exhibited their peak maxima at different delay times, depending on the element, after the end of the GD pulse. Such ion signal delays have been measured for different selected isotopes, covering a mass spectrum from light to heavy isotopes at different conditions of pressure and applied power. The results showed that ion signal delays are influenced by both the isotope mass and the pressure of the GD. Furthermore, GD operating conditions (pressure and applied power) were optimised in terms of sensitivity, using a bulk glass certified reference material (NIST 1411). The best analytical performance was observed at low pressure (150-200 Pa) and high applied power (135 W). Moreover, different pulse GD duty cycles (relationship between pulse duration and pulse period) were investigated. An optimum value of 50-65% duty-cycle was selected considering the signal stability and the signal intensity. The previously optimized pulsed-rf-GD-TOFMS system was then evaluated for qualitative in-depth profile analysis of thin coatings deposited onto thick glass substrates. High depth resolution (nm range), comparable to that obtained using rf-GD-OES was achieved. However, the observed depth resolution using the ToF-SIMS system is still superior. In this sense, analytical figures of merit observed in our pulsed-rf-GD-TOFMS demonstrate its great analytical potential for high depth resolution analysis of coated glasses.
引用
收藏
页码:1239 / 1246
页数:8
相关论文
共 50 条
  • [1] A radiofrequency glow-discharge-time-of-flight mass spectrometer for direct analysis of glasses
    Jorge Pisonero
    José Manuel Costa
    Rosario Pereiro
    Nerea Bordel
    Alfredo Sanz-Medel
    [J]. Analytical and Bioanalytical Chemistry, 2004, 379 : 658 - 667
  • [2] A radiofrequency glow-discharge-time-of-flight mass spectrometer for direct analysis of glasses
    Pisonero, J
    Costa, JM
    Pereiro, R
    Bordel, N
    Sanz-Medel, A
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) : 658 - 667
  • [3] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    20151900828891
    [J]. Fernández, Beatriz (fernandezbeatriz@uniovi.es), 1600, Royal Society of Chemistry (30):
  • [4] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    Bouza, Marcos
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (05) : 1108 - 1116
  • [5] Technical note: Characterization of gold coated ceramics by radiofrequency pulsed glow discharge - time of flight mass spectrometry
    Bouza, Marcos
    Lobo, Lara
    Muniz, Rocio
    Pereiro, Rosario
    Esparza, Joseba
    Antonio Garcia, Jose
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (03) : 502 - 507
  • [6] CHARACTERIZATION OF A RADIOFREQUENCY GLOW-DISCHARGE TIME-OF-FLIGHT MASS-SPECTROMETER
    MYERS, DP
    HEINTZ, MJ
    MAHONEY, PP
    LI, G
    HIEFTJE, GM
    [J]. APPLIED SPECTROSCOPY, 1994, 48 (11) : 1337 - 1346
  • [7] Characterization of thin film tandem solar cells by radiofrequency pulsed glow discharge - Time of flight mass spectrometry
    Fernandez, Beatriz
    Lobo, Lara
    Reininghaus, Nies
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    [J]. TALANTA, 2017, 165 : 289 - 296
  • [8] MICROSECOND PULSED GLOW-DISCHARGE TIME-OF-FLIGHT MASS-SPECTROMETER
    HANG, W
    YANG, PY
    WANG, XR
    YANG, CL
    SU, YX
    HUANG, BL
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) : 590 - 594
  • [9] Depth Profile Analysis of Amorphous Silicon Thin Film Solar Cells by Pulsed Radiofrequency Glow Discharge Time of Flight Mass Spectrometry
    Alvarez-Toral, Aitor
    Sanchez, Pascal
    Menendez, Armando
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (02) : 305 - 314
  • [10] Lumas-30 time-of-flight mass spectrometer with pulsed glow discharge for direct determination of nitrogen in steel
    Ganeev, A. A.
    Gubal', A. R.
    Mosichev, V. I.
    Pershin, N. V.
    Petrov, S. N.
    Potapov, S. V.
    Uskov, K. N.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (14) : 1411 - 1416