Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis

被引:0
|
作者
Auristela Solà-Vázquez
Beatriz Fernández
José M. Costa-Fernández
Rosario Pereiro
Alfredo Sanz-Medel
机构
[1] University of Oviedo,Department of Physical and Analytical Chemistry, Faculty of Chemistry
来源
关键词
Pulsed glow discharge; Time-of-flight mass spectrometry; Speciation analysis; Organic compounds;
D O I
暂无
中图分类号
学科分类号
摘要
The performance of radiofrequency (rf) millisecond pulsed glow discharge (PGD) coupled to a fast orthogonal time-of-flight mass spectrometer (TOFMS) for chemical characterization and quantification of organic volatile compounds was investigated by using two different GD chamber designs. The designs investigated had substantial differences in the way that the volatile organic compound is introduced into the GD and the distance between the cathode and the sampling cone of the mass spectrometer. Bromochloromethane was selected as the model analyte because of the practical interest of determining trihalomethanes at low concentrations, and also because of both its low boiling point (to avoid problems associated with condensations in the interface) and the fact that it has two different heteroatoms, making the fragmentation patterns easier to follow. Pulse shapes of element, fragment, and molecular parent ions obtained by using the two GD chambers under investigation were critically compared. Results revealed the critical effect of the GD chamber geometry in obtaining the three types of chemical information, temporally discriminated. The spectra of the gaseous samples and of a polymer containing TBBPA (solid sample) were also compared. Detection limits for bromochloromethane in the order of low ng L−1, and the required high tolerance of the plasmas to the introduction of organic vapours, were achieved using one of the proposed GD designs. The capability of the designed system for the analysis of other volatile compounds, for example dimethyl disulfide and dimethyl selenide, was also successfully evaluated, making use of the analytical potential of the information obtained from the different pulse time regions.
引用
收藏
页码:7431 / 7443
页数:12
相关论文
共 50 条
  • [1] Improving pulsed radiofrequency glow discharge for time-of-flight mass spectrometry simultaneous elemental and molecular analysis
    Sola-Vazquez, Auristela
    Fernandez, Beatriz
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (29) : 7431 - 7443
  • [2] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [3] Pulsed Radiofrequency Glow Discharge Time-of-Flight Mass Spectrometry for Nanostructured Materials Characterization
    Bustelo, Marta
    Fernandez, Beatriz
    Pisonero, Jorge
    Pereiro, Rosario
    Bordel, Nerea
    Vega, Victor
    Prida, Victor M.
    Sanz-Medel, Alfredo
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (01) : 329 - 337
  • [4] An ion source for radiofrequency-pulsed glow discharge time-of-flight mass spectrometry
    Gonzalez Gago, C.
    Lobo, L.
    Pisonero, J.
    Bordel, N.
    Pereiro, R.
    Sanz-Medel, A.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 76 : 159 - 165
  • [5] Investigation of the afterglow time regime in pulsed radiofrequency glow discharge time-of-flight mass spectrometry
    Gonzales Gago, C.
    Bordel, N.
    Pereiro, R.
    Sanz-Medel, A.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2011, 46 (08): : 757 - 763
  • [6] Consideration of a millisecond pulsed glow discharge time-of-flight mass spectrometer for concurrent elemental and molecular analysis
    Steiner, RE
    Lewis, CL
    Majidi, V
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) : 1537 - 1541
  • [7] Isotope dilution mass spectrometry for quantitative elemental analysis of powdered samples by radiofrequency pulsed glow discharge time of flight mass spectrometry
    Alvarez-Toral, Aitor
    Fernandez, Beatriz
    Malherbe, Julien
    Claverie, Fanny
    Molloy, John L.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    [J]. TALANTA, 2013, 115 : 657 - 664
  • [8] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    Lobo, L.
    Tuccitto, N.
    Bordel, N.
    Pereiro, R.
    Pisonero, J.
    Licciardello, A.
    Tempez, A.
    Chapon, P.
    Sanz-Medel, A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2863 - 2869
  • [9] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    L. Lobo
    N. Tuccitto
    N. Bordel
    R. Pereiro
    J. Pisonero
    A. Licciardello
    A. Tempez
    P. Chapon
    A. Sanz-Medel
    [J]. Analytical and Bioanalytical Chemistry, 2010, 396 : 2863 - 2869
  • [10] Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis
    20151900828891
    [J]. Fernández, Beatriz (fernandezbeatriz@uniovi.es), 1600, Royal Society of Chemistry (30):