Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis

被引:16
|
作者
Bouza, Marcos [1 ]
Pereiro, Rosario [1 ]
Bordel, Nerea [2 ]
Sanz-Medel, Alfredo [1 ]
Fernandez, Beatriz [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Univ Oviedo, Dept Phys, E-33006 Oviedo, Spain
关键词
DEPTH-PROFILE ANALYSIS;
D O I
10.1039/c4ja00474d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical potential of radiofrequency pulsed glow discharge time of flight mass spectrometry (rf-PGD-ToFMS) is investigated for quantitative depth profiling analysis of glasses and thin conductive and non-conductive layers on glasses. PGD in combination with ToFMS can allow the reduction or even removal of spectral interferences by selecting a proper GD pulse interval. Thus, discrimination of potential polyatomic interferences for several analytes (e.g., Si-28(+), K-39(+), Ca-44(+), and Ti-48(+)) was investigated by selecting appropriate time positions along the GD pulse profile. In this paper, the determination of compositional depth profiles of coated glasses was performed by resorting to a multi-matrix calibration procedure. For this purpose, conductive as well as non-conductive certified reference materials were employed to build the analytical calibration curves. Results show that rf-PGD-ToFMS allows us to discriminate the different layers of the samples and the nominal values for element concentrations and layer thicknesses were in agreement with experimental results obtained using the proposed quantification strategy. Moreover, the capability of rf-PGD-ToFMS to provide a full mass spectrum every 33 mu s enable the identification of unexpected elements which can be present as contaminants in very thin layers (e.g. Cd, Sn, Te and Sb).
引用
下载
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [21] RF-pulsed glow discharge time-of-flight mass spectrometry for glass analysis: Investigation of the ion source design
    Bouza, Marcos
    Fernandez, Beatriz
    Gonzalez-Gago, Cristina
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICA CHIMICA ACTA, 2012, 756 : 30 - 36
  • [22] Depth Profile Analysis of Amorphous Silicon Thin Film Solar Cells by Pulsed Radiofrequency Glow Discharge Time of Flight Mass Spectrometry
    Alvarez-Toral, Aitor
    Sanchez, Pascal
    Menendez, Armando
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    Fernandez, Beatriz
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (02) : 305 - 314
  • [23] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    A. A. Ganeev
    A. R. Gubal
    S. V. Potapov
    S. E. Pogarev
    S. E. Sholupov
    K. N. Uskov
    I. S. Ivanov
    Journal of Analytical Chemistry, 2013, 68 : 1205 - 1211
  • [24] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [25] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    Ganeev, A. A.
    Gubal, A. R.
    Potapov, S. V.
    Pogarev, S. E.
    Sholupov, S. E.
    Uskov, K. N.
    Ivanov, I. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (14) : 1205 - 1211
  • [26] Critical evaluation of the potential of radiofrequency pulsed glow discharge-time-of-flight mass spectrometry for depth-profile analysis of innovative materials
    Pisonero, Jorge
    Bordel, Nerea
    Gonzalez de Vega, Claudia
    Fernandez, Beatriz
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (17) : 5655 - 5662
  • [27] Pulsed radiofrequency glow discharge time-of-flight mass spectrometry: Depth profile analysis of multilayers on conductive and non-conductive substrates
    Lobo, Lara
    Fernandez, Beatriz
    Aranaz, Marta
    Fernandez Lorenzo, Andres
    Ignacio Martin-Carbajo, Jose
    Pereiro, Rosario
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 168
  • [28] Critical evaluation of the potential of radiofrequency pulsed glow discharge–time-of-flight mass spectrometry for depth-profile analysis of innovative materials
    Jorge Pisonero
    Nerea Bordel
    Claudia Gonzalez de Vega
    Beatriz Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2013, 405 : 5655 - 5662
  • [29] Pulsed radiofrequency glow discharge time-of-flight mass spectrometry for molecular depth profiling of polymer-based films
    Tuccitto, Nunzio
    Lobo, Lara
    Tempez, Agnes
    Delfanti, Ivan
    Chapon, Patrick
    Canulescu, Stela
    Bordel, Nerea
    Michler, Johann
    Licciardello, Antonino
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (05) : 549 - 556
  • [30] Volatile organic compound analysis by pulsed glow discharge time of flight mass spectrometry as a structural elucidation tool
    Bouza, Marcos
    Fandino, Jonatan
    Bordel, Nerea
    Pereiro, Rosario
    Sanz-Medel, Alfredo