Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis

被引:16
|
作者
Bouza, Marcos [1 ]
Pereiro, Rosario [1 ]
Bordel, Nerea [2 ]
Sanz-Medel, Alfredo [1 ]
Fernandez, Beatriz [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Univ Oviedo, Dept Phys, E-33006 Oviedo, Spain
关键词
DEPTH-PROFILE ANALYSIS;
D O I
10.1039/c4ja00474d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical potential of radiofrequency pulsed glow discharge time of flight mass spectrometry (rf-PGD-ToFMS) is investigated for quantitative depth profiling analysis of glasses and thin conductive and non-conductive layers on glasses. PGD in combination with ToFMS can allow the reduction or even removal of spectral interferences by selecting a proper GD pulse interval. Thus, discrimination of potential polyatomic interferences for several analytes (e.g., Si-28(+), K-39(+), Ca-44(+), and Ti-48(+)) was investigated by selecting appropriate time positions along the GD pulse profile. In this paper, the determination of compositional depth profiles of coated glasses was performed by resorting to a multi-matrix calibration procedure. For this purpose, conductive as well as non-conductive certified reference materials were employed to build the analytical calibration curves. Results show that rf-PGD-ToFMS allows us to discriminate the different layers of the samples and the nominal values for element concentrations and layer thicknesses were in agreement with experimental results obtained using the proposed quantification strategy. Moreover, the capability of rf-PGD-ToFMS to provide a full mass spectrum every 33 mu s enable the identification of unexpected elements which can be present as contaminants in very thin layers (e.g. Cd, Sn, Te and Sb).
引用
下载
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [41] Microsecond pulsed versus direct current glow discharge as ion sources for analytical glow discharge-time of flight mass spectrometry
    Martín, Antonio
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Journal of Analytical Atomic Spectrometry, 2007, 22 (09): : 1179 - 1183
  • [42] Depth profile analysis of rare earth elements in corroded steels by pulsed glow discharge - time of flight mass spectrometry
    Muniz, Rocio
    Lobo, Lara
    Kerry, Timothy
    Sharrad, Clint A.
    Pereiro, Rosario
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (07) : 1306 - 1311
  • [43] Direct determination of uranium and thorium in minerals by time-of-flight mass spectrometry with pulsed glow discharge
    Ganeev, Aleksandr
    Bogdanova, Oksana
    Ivanov, Ilia
    Burakov, Boris
    Agafonova, Natalia
    Korotetski, Boris
    Gubal, Anna
    Solovyev, Nikolay
    Iakovleva, Evgenia
    Sillanpaa, Mika
    RSC ADVANCES, 2015, 5 (99) : 80901 - 80910
  • [44] Evaluation of a glow discharge chamber coupled to time of flight mass spectrometry for the analysis of small gas volumes and bubbles in glass
    Gonzalez Gago, C.
    Pisonero, J.
    Pereiro, R.
    Bordel, N.
    Mazon Ramos, P.
    Sanz-Medel, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (10) : 1612 - 1617
  • [45] Capabilities of radiofrequency pulsed glow discharge-time of flight mass spectrometry for molecular screening in polymeric materials: positive versus negative ion mode
    Lobo, Lara
    Fernandez, Beatriz
    Muniz, Rocio
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (01) : 212 - 219
  • [46] Depth profiling by pulsed glow discharge time-of-flight mass spectrometry with a combined hollow cathode cell
    Gubal, Anna
    Chuchina, Victoria
    Lyalkin, Yegor
    Mikhailovskii, Vladimir
    Yakobson, Viktor
    Solovyev, Nikolay
    Ganeev, Alexander
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (08) : 1587 - 1596
  • [47] Quantitative depth profile analysis by direct current glow discharge time of flight mass spectrometry
    Sanz-Medel, A. (asm@correo.uniovi.es), 1600, Royal Society of Chemistry (18):
  • [48] Quantitative depth profile analysis by direct current glow discharge time of flight mass spectrometry
    Peláez, MV
    Costa-Fernández, JM
    Pereiro, R
    Bordel, N
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (08) : 864 - 871
  • [49] CHARACTERIZATION OF A RADIOFREQUENCY GLOW-DISCHARGE TIME-OF-FLIGHT MASS-SPECTROMETER
    MYERS, DP
    HEINTZ, MJ
    MAHONEY, PP
    LI, G
    HIEFTJE, GM
    APPLIED SPECTROSCOPY, 1994, 48 (11) : 1337 - 1346
  • [50] Present and future of glow discharge - Time of flight mass spectrometry in analytical chemistry
    Pereiro, Rosario
    Sola-Vazquez, Auristela
    Lobo, Lara
    Pisonero, Jorge
    Bordel, Nerea
    Manuel Costa, Jose
    Sanz-Medel, Alfredo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (06) : 399 - 412