Depth profiling by pulsed glow discharge time-of-flight mass spectrometry with a combined hollow cathode cell

被引:5
|
作者
Gubal, Anna [1 ]
Chuchina, Victoria [1 ]
Lyalkin, Yegor [1 ]
Mikhailovskii, Vladimir [1 ]
Yakobson, Viktor [2 ]
Solovyev, Nikolay [1 ,3 ]
Ganeev, Alexander [1 ,4 ]
机构
[1] St Petersburg State Univ, Inst Chem, Univ Skaya Nab 7-9, St Petersburg 199034, Russia
[2] Joint Stock Co Res & Prod Corp SI Vavilova, Ul Babushkina 36-1, St Petersburg 192171, Russia
[3] Inst Technol Sligo, Ash Lane, Sligo F91 YW50, Ireland
[4] Inst Toxicol Fed Med Biol Agcy, Ul Bekhtereva 1, St Petersburg 192019, Russia
基金
俄罗斯科学基金会;
关键词
OPTICAL-EMISSION SPECTROSCOPY; POTASSIUM TITANYL PHOSPHATE; MULTILAYER METAL COATINGS; CRYSTAL MATERIALS; THIN; PLASMA; QUANTIFICATION; RESOLUTION; ELEMENTS; SURFACE;
D O I
10.1039/d0ja00088d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combined hollow cathode microsecond direct current pulsed glow discharge time-of-flight mass spectrometry (CHC ms-DC-PGD TOFMS) system has proved its efficiency for quantification; however, it has not been properly tested for the purpose of depth analysis until now, to the best of the authors' knowledge. The aim of the current study was to investigate the capabilities of this glow discharge source type for depth profiling. Special attention was paid to the alteration of depth resolution during the sputtering and the effect of discharge parameters on the crater shape in different types of solid samples. Both dielectric and conductive samples were tested, including: a Ni film on silicon, a Si film on borosilicate glass, and IR-reflective dielectric multilayer (mirror) coatings. Crater shapes were investigated after combined hollow cathode cell sputtering to ensure reliable profiling. For dielectric materials, including multilayer coatings, the deposition of a thin conducting layer (Ag or Ta) on the sample surface was demonstrated to result in reliable sputtering with adequate depth resolution of the profiling. This preliminary sample coating provided both the formation of required surface conductivity and reduction of the negative effect of atmospheric gases and water surface contamination at the beginning of sample sputtering. A silicon-coated borosilicate glass specimen was tested for potential quantitative profiling, showing promising results. The CHC ms-DC-PGD TOFMS system used was capable of analyzing the layers of varied thickness in the range from tens of nanometers to several micrometers. The depth resolution was 5 nm and 25 nm for conducting and dielectric layers, respectively.
引用
收藏
页码:1587 / 1596
页数:10
相关论文
共 50 条
  • [1] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [2] Pulsed radiofrequency glow discharge time-of-flight mass spectrometry for molecular depth profiling of polymer-based films
    Tuccitto, Nunzio
    Lobo, Lara
    Tempez, Agnes
    Delfanti, Ivan
    Chapon, Patrick
    Canulescu, Stela
    Bordel, Nerea
    Michler, Johann
    Licciardello, Antonino
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (05) : 549 - 556
  • [3] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [4] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    A. A. Ganeev
    A. R. Gubal
    S. V. Potapov
    S. E. Pogarev
    S. E. Sholupov
    K. N. Uskov
    I. S. Ivanov
    Journal of Analytical Chemistry, 2013, 68 : 1205 - 1211
  • [5] Elimination of water interference in pulsed glow discharge time-of-flight mass spectrometry
    Ganeev, A. A.
    Gubal, A. R.
    Potapov, S. V.
    Pogarev, S. E.
    Sholupov, S. E.
    Uskov, K. N.
    Ivanov, I. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (14) : 1205 - 1211
  • [6] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [7] Model of microsecond pulsed glow discharge in hollow cathode for mass spectrometry
    Voronov, M.
    Ganeev, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (05) : 416 - 426
  • [8] Microsecond-pulsed glow discharge time-of-flight mass spectrometry: Analytical advantages
    Hang, W
    Baker, C
    Smith, BW
    Winefordner, JD
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) : 143 - 149
  • [9] Microsecond-pulsed Grimm glow discharge as a source for time-of-flight mass spectrometry
    Yang, CL
    Mohill, M
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) : 1255 - 1260
  • [10] Pulsed Radiofrequency Glow Discharge Time-of-Flight Mass Spectrometry for Nanostructured Materials Characterization
    Bustelo, Marta
    Fernandez, Beatriz
    Pisonero, Jorge
    Pereiro, Rosario
    Bordel, Nerea
    Vega, Victor
    Prida, Victor M.
    Sanz-Medel, Alfredo
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 329 - 337