Evaluation of effective dose from a RANDO phantom in videofluorography diagnostic procedures for diagnosing dysphagia

被引:8
|
作者
Iwai, K. [1 ]
Hashimoto, K.
Nishizawa, K. [2 ]
Sawada, K.
Honda, K.
机构
[1] Nihon Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Chiyoda Ku, Tokyo 1018310, Japan
[2] Natl Inst Radiol Sci, Div Med Phys, Chiba 260, Japan
关键词
effective dose; equivalent dose; videofluorography; dysphagia; PHARYNGEAL WALL; PATIENT; SWALLOW;
D O I
10.1259/dmfr/51307488
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Videofluorography (VF) is useful for diagnosing dysphagia; however, few reports have investigated appropriate effective doses for VF. The present study aimed to estimate the effective radiation dose in VF for diagnosis of dysphagia. Methods: Radiation doses to tissues and organs were measured using the anthropomorphic RANDO woman phantom as an equivalent to the human body. Effective doses were estimated according to the recommendations of the International Commission on Radiological Protection (ICRP) 60 in 1990 and IRCP 103 in 2007. The tissues measured were those recommended by ICRP 60 and ICRP 103 including gonads (ovaries and testes), red bone marrow and tissues in which excessive radiation commonly causes malignant tumours including lung, thyroid gland, stomach, large intestine, liver, oesophagus, bladder, breast, bone marrow, skin, brain and salivary gland. Skin dose was also measured using thermoluminescent dosimeters. Results: Using ICRP 103, the effective dose was estimated as 118.1 mu Sv at a tube voltage of 50 kV and 82.4 mu Sv at 45 kV. However, using ICRP 60 the effective dose for 1 min of VF was estimated at 62.4 mu Sv and 47.2 mu Sv under the same exposure conditions. Conclusions: Using ICRP 103, the effective dose for VF per examination at a total estimation time of 1 min was estimated as approximately 2.5-8.3 times that observed for digital panoramic radiography and 1/12 to 3 times depending on the measurement device for cone beam CT (CBCT). This value can be decreased in the future using a smaller irradiation field and decreased time for examination in VF in the future. Dentomaxillofacial Radiology (2011) 40, 96-101. doi: 10.1259/dmfr/51307488
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [31] Organ and effective dose evaluation in coronary angiography by using a 320 MDCT based on in-phantom dose measurements with TLDs
    Lu, Heqing
    Zhuo, Weihai
    Xu, Bing
    Wang, Minjie
    JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (03) : 597 - 609
  • [32] Typical effective dose values from diagnostic and interventional radiology
    Ahmed, Nada A.
    APPLIED RADIATION AND ISOTOPES, 2023, 192
  • [33] Kerma Area Product Method for Effective Dose Estimation During Lumbar Epidural Steroid Injection Procedures: Phantom Study
    Kim, Sangroh
    Toncheva, Greta
    Anderson-Evans, Colin
    Huh, Billy K.
    Gray, Linda
    Yoshizumi, Terry
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (06) : 1726 - 1730
  • [34] Effective dose to staff from interventional procedures: estimations from single and double dosimetry
    Kuipers, Gerritjan
    Velders, Xandra L.
    RADIATION PROTECTION DOSIMETRY, 2009, 136 (02) : 95 - 100
  • [35] Determining and Managing Fetal Radiation Dose from Diagnostic Radiology Procedures in Turkey
    Ozbayrak, Mustafa
    Cavdar, Iffet
    Seven, Mehmet
    Uslu, Lebriz
    Yeyin, Nami
    Tanyildizi, Handan
    Abuqbeitah, Mohammad
    Acikgoz, A. Serdar
    Tuten, Abdullah
    Demir, Mustafa
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (06) : 1276 - 1282
  • [36] CALCULATION OF PATIENT SKIN DOSE FROM DIAGNOSTIC-X-RAY PROCEDURES
    SHRIMPTON, PC
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (689): : 483 - 485
  • [37] RADIATION DOSE TO SKIN AND TO GONADS FROM DIAGNOSTIC X-RAY PROCEDURES
    DUGGAN, HE
    OLDE, GL
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1963, 89 (22) : 1144 - &
  • [38] IN-VIVO MEASUREMENTS OF GONADAL DOSE RESULTING FROM DIAGNOSTIC RADIOGRAPHIC PROCEDURES
    CARLSON, V
    HRANITZK.EB
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (01): : 124 - &
  • [39] CALCULATION OF PATIENT SKIN DOSE FROM DIAGNOSTIC-X-RAY PROCEDURES
    EDMONDS, IR
    BRITISH JOURNAL OF RADIOLOGY, 1984, 57 (680): : 733 - 734
  • [40] Software for the estimation of organ equivalent and effective doses from diagnostic radiology procedures
    Osei, E. K.