Organ and effective dose evaluation in coronary angiography by using a 320 MDCT based on in-phantom dose measurements with TLDs

被引:3
|
作者
Lu, Heqing [1 ,2 ]
Zhuo, Weihai [1 ]
Xu, Bing [3 ]
Wang, Minjie [3 ]
机构
[1] Fudan Univ, Dept Radiat Protect, Inst Radiat Med, Shanghai 200032, Peoples R China
[2] Tongji Univ, Sch Med, Shanghai Matern & Infant Hosp 1, Dept Med Equipment, Shanghai 201204, Peoples R China
[3] Shanghai Changhai Hosp, Dept Diagnost Radiol, Shanghai 200433, Peoples R China
基金
中国国家自然科学基金;
关键词
computed tomography coronary angiography; multi detector computed tomography; thermoluminescent dosimeter; dose length product; effective dose; FILTERED BACK-PROJECTION; ITERATIVE RECONSTRUCTION; IMAGE QUALITY; CT ANGIOGRAPHY; ALGORITHMS; DOSIMETRY; MM;
D O I
10.1088/0952-4746/35/3/597
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study is to estimate the organ and effective dose (E) from computed tomography coronary angiography (CTCA) on a 320-MDCT scanner. Radiation dose was estimated for the prospectively ECG-gated CTCA in a male phantom. A total of 451 chips of thermoluminescent dosimeter were implanted in the phantom for measuring the organ doses. The effective doses were calculated using measured organ doses and the tissue-weighting factors. The dose length product (DLP) values were recorded and used to develop the conversion coefficient k = 0.017 mSv.(mGy.cm)(-1) (E/DLP). In a 3-beat acquisition, the organ doses ranged from 0.24 to 71.55 mGy, and the doses in breast, bone surface, oesophagus, and lung were higher than 20 mGy. The effective doses in 2-beat and 3-beat acquisition were estimated to be 14.3 and 24.3 mSv. More beats of acquisition led to higher radiation dose. The reported k values for chest CT scan can be used to roughly estimate the E value from CTCA for 320 MDCT.
引用
收藏
页码:597 / 609
页数:13
相关论文
共 50 条
  • [1] Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters
    Kawaura, Chiyo
    Aoyama, Takahiko
    Koyama, Shuji
    Achiwa, Masataka
    Mori, Masaki
    RADIATION PROTECTION DOSIMETRY, 2006, 118 (04) : 421 - 430
  • [2] Evaluation of Radiation Dose in Coronary Computed Tomography-Angiography Examinations: Using Organ dose and Effective dose
    Shibata, Hideki
    Kondo, Yuya
    Fukada, Shinji
    Asada, Yasuki
    Kozawa, Isao
    RADIATION PHYSICS AND CHEMISTRY, 2019, 158 : 218 - 221
  • [3] Comparison of in-phantom dose distributions for coronary angiography using an x-ray machine and synchrotron radiation
    Nariyama, N
    Tanaka, S
    Nakane, Y
    Nakashima, H
    Hirayama, H
    Ban, S
    Namito, Y
    Hyodo, K
    Takeda, T
    MEDICAL PHYSICS, 2001, 28 (01) : 16 - 21
  • [4] An Easy Method to Evaluate Radiation Peak Skin Dose in the Coronary Angiography by Using a Simulating Phantom and Thermoluminescent Dosimeters (TLDs)
    Hsu, Kai Chieh
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (15) : S51 - S52
  • [5] Comparison of Radiation Dose and Image Quality: 320-MDCT Versus 64-MDCT Coronary Angiography
    Khan, Atif
    Khosa, Faisal
    Nasir, Khurram
    Yassin, Aya
    Clouse, Melvin E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (01) : 163 - 168
  • [6] Iterative reconstruction of pulmonary MDCT angiography: Effects on image quality, effective dose and estimated organ dose to the breast
    Zizka, Jan
    Ryska, Pavel
    Stepanovska, Jana
    Poulova, Zuzana
    Klzo, Ludovit
    Grepl, Jakub
    Cermakova, Eva
    BIOMEDICAL PAPERS-OLOMOUC, 2014, 158 (02): : 259 - 264
  • [7] A phantom for effective dose measurement: Organ dose distribution assessment based on a numerical approach
    Furstoss, C.
    Menard, S.
    Clairand, I.
    Chau, Q.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 180 - 184
  • [8] ESTIMATION OF THE MEAN ORGAN DOSES AND THE EFFECTIVE DOSE EQUIVALENT FROM RANDO PHANTOM MEASUREMENTS
    GOLIKOV, VY
    NIKITIN, VV
    HEALTH PHYSICS, 1989, 56 (01): : 111 - 115
  • [9] Polyp detection with MDCT:: A phantom-based evaluation of the impact of dose and spatial resolution
    Özgün, A
    Rollvén, E
    Blomqvist, L
    Bremmer, S
    Odh, R
    Fransson, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 1181 - 1188
  • [10] Organ Doses, Effective Dose, and Cancer Risk From Coronary CT Angiography Examinations
    Mahmoodi, Maede
    Chaparian, Ali
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (05) : 1131 - 1136