Evaluation of effective dose from a RANDO phantom in videofluorography diagnostic procedures for diagnosing dysphagia

被引:8
|
作者
Iwai, K. [1 ]
Hashimoto, K.
Nishizawa, K. [2 ]
Sawada, K.
Honda, K.
机构
[1] Nihon Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Chiyoda Ku, Tokyo 1018310, Japan
[2] Natl Inst Radiol Sci, Div Med Phys, Chiba 260, Japan
关键词
effective dose; equivalent dose; videofluorography; dysphagia; PHARYNGEAL WALL; PATIENT; SWALLOW;
D O I
10.1259/dmfr/51307488
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Videofluorography (VF) is useful for diagnosing dysphagia; however, few reports have investigated appropriate effective doses for VF. The present study aimed to estimate the effective radiation dose in VF for diagnosis of dysphagia. Methods: Radiation doses to tissues and organs were measured using the anthropomorphic RANDO woman phantom as an equivalent to the human body. Effective doses were estimated according to the recommendations of the International Commission on Radiological Protection (ICRP) 60 in 1990 and IRCP 103 in 2007. The tissues measured were those recommended by ICRP 60 and ICRP 103 including gonads (ovaries and testes), red bone marrow and tissues in which excessive radiation commonly causes malignant tumours including lung, thyroid gland, stomach, large intestine, liver, oesophagus, bladder, breast, bone marrow, skin, brain and salivary gland. Skin dose was also measured using thermoluminescent dosimeters. Results: Using ICRP 103, the effective dose was estimated as 118.1 mu Sv at a tube voltage of 50 kV and 82.4 mu Sv at 45 kV. However, using ICRP 60 the effective dose for 1 min of VF was estimated at 62.4 mu Sv and 47.2 mu Sv under the same exposure conditions. Conclusions: Using ICRP 103, the effective dose for VF per examination at a total estimation time of 1 min was estimated as approximately 2.5-8.3 times that observed for digital panoramic radiography and 1/12 to 3 times depending on the measurement device for cone beam CT (CBCT). This value can be decreased in the future using a smaller irradiation field and decreased time for examination in VF in the future. Dentomaxillofacial Radiology (2011) 40, 96-101. doi: 10.1259/dmfr/51307488
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [21] ANNUAL PER CAPUT EFFECTIVE DOSE EQUIVALENT OF BEIJING INHABITANTS FROM DIAGNOSTIC-X-RAY PROCEDURES
    ZHENG, JZ
    HEALTH PHYSICS, 1990, 59 (06): : 939 - 940
  • [22] Patient risk associated with nuclear medicine procedures: An evaluation of effective dose
    Brunner, Bradley
    Zimmer, Mike
    Riehle, Lisa
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [23] Relationships between entrance skin dose, effective dose and dose area product for patients in diagnostic and interventional cardiac procedures
    Hansson, B
    Karambatsakidou, A
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 141 - 144
  • [24] COLLECTIVE EFFECTIVE DOSE FROM DIAGNOSTIC RADIOLOGY IN UKRAINE
    Stadnyk, L.
    Shalopa, O.
    Nosyk, O.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 146 - 149
  • [25] Cutaneous melanoma; diagnostic procedures and their evaluation in diagnosing and mapping sentinel nodes. Part 2
    Valsamaki, Pipitsa
    Zanglis, Antonios
    Chatzipetrou, Alexia
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2010, 13 (02): : 191 - 196
  • [26] Monte Carlo simulations of dose from microCT imaging procedures in a realistic mouse phantom
    Taschereau, R
    Chow, PL
    Chatziioannou, AF
    MEDICAL PHYSICS, 2006, 33 (01) : 216 - 224
  • [27] GONADAL EXPOSURE DOSE FROM DIAGNOSTIC X-RAY PROCEDURES
    FELDMAN, A
    BABCOCK, GC
    LANIER, RR
    MORKOVIN, D
    RADIOLOGY, 1958, 71 (02) : 197 - 207
  • [28] Patient Radiation Dose from Medical Diagnostic Imaging Procedures in 2018
    Tsovyanov, A. G.
    Sivenkov, A. G.
    Zhuravleva, V. E.
    Kosterev, V. V.
    ATOMIC ENERGY, 2021, 129 (06) : 362 - 366
  • [29] Patient Radiation Dose from Medical Diagnostic Imaging Procedures in 2018
    A. G. Tsovyanov
    A. G. Sivenkov
    V. E. Zhuravleva
    V. V. Kosterev
    Atomic Energy, 2021, 129 : 362 - 366
  • [30] Measurement of reaction rate distributions in phantom irradiated by intermediate energy neutrons for effective dose evaluation
    Nakane, Y
    Nakashima, H
    Sakamoto, Y
    Tanaka, S
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D343 - D345