Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer

被引:19
|
作者
Kreissl, Hannah [1 ]
Neiger, Reto [1 ]
机构
[1] Univ Giessen, Small Anim Clin, Dept Clin Studies, Giessen, Germany
关键词
canine; fever; monitoring; thermoregulation; MICROCHIP TRANSPONDER; TYMPANIC TEMPERATURE; CORE TEMPERATURE; OTITIS-EXTERNA; CHILDREN; AGREEMENT; ARTERY; CATS; SKIN; ACCURACY;
D O I
10.1111/vec.12302
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo assess the accuracy of obtaining body temperatures in dogs with a noncontact infrared thermometer (NCIT) on the cornea compared with a rectal digital thermometer (RDT). DesignProspective single center study. SettingUniversity teaching hospital. AnimalsThree hundred dogs presented with low, normal, or high body temperatures. InterventionsThree body temperature readings were measured by an RDT and by an NCIT on the cornea of the left eye by 2 investigators (experienced and inexperienced). Results obtained by the 2 methods were compared. Measurements and Main ResultsMedian body temperature measured by the experienced investigator with the RDT and the NCIT were 38.3 degrees C (range 35.5 degrees C-41.1 degrees C; 95% CI: 38.2-38.4 degrees C) and 37.7 degrees C (35.9 degrees C-40.1 degrees C; 95% CI: 37.7 degrees C-37.9 degrees C), respectively. Measurement of RDT as well as of NCIT correlated well between both investigators (r(RDT) = 0.94; r(NCIT) = 0.82; respectively, P < 0.001 for both methods). Mean RDT and NCIT-temperature correlated poorly (r = 0.43; P < 0.001) when taken by the experienced investigator and even less by the nonexperienced investigator (r = 0.38; P < 0.001). Repeatability of the NCIT revealed an unsatisfactory value (0.24 degrees C) compared to RDT measurement (0.12 degrees C). Agreement between both devices in measuring low, normal, and high values, calculated by Cohens-Kappa, was unsatisfactory (k = 0.201; P < 0.001). Calculating the receiver operating characteristic curve to determine the best threshold for fever (defined as RDT temperature >39.0 degrees C) showed an area under the curve of 0.76. Mean discomfort score was significantly lower using NCIT compared to RDT measurement (P < 0.001). ConclusionsThere was poor agreement between body temperatures obtained by RDT and NCIT. The corneal NCIT measurement tends to underrecognize hypothermic and hyperthermic conditions. Although the use of the NCIT yields faster results and is significantly more comfortable for the dog than the RDT measurement, it cannot be recommended in dogs at this time.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 32 条
  • [1] Comparison of body temperature in cats using a veterinary infrared thermometer and a digital rectal thermometer
    Kunkle, GA
    Nicklin, CF
    Sullivan-Tamboe, DL
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2004, 40 (01) : 42 - 46
  • [2] Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
    Cugmas, Blaz
    Susteric, Primoz
    Gorenjec, Nina Ruzic
    Plavec, Tanja
    VETERINARY AND ANIMAL SCIENCE, 2020, 9
  • [3] A noninvasive method of temperature measurement using a noncontact handheld infrared thermometer fails to correlate with rectal temperature in dogs and cats
    Barton, James C.
    Didier, Martine D.
    Silvestrini, Paolo
    German, Alexander J.
    Ferriani, Riccardo
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2022, 260 (07): : 752 - 757
  • [4] Variability in the measurement of corneal temperature using a noncontact infrared thermometer
    Koçak, I
    Orgül, S
    Flammer, J
    OPHTHALMOLOGICA, 1999, 213 (06) : 345 - 349
  • [5] Comparison of a non-contact infrared thermometer with a rectal digital thermometer for use in ewes
    Katsoulos, P. D.
    Athanasiou, L. V.
    Karatzia, M. A.
    Valasi, I.
    Boscos, C.
    Karatzias, H.
    SMALL RUMINANT RESEARCH, 2016, 143 : 84 - 88
  • [6] Noncontact infrared thermometer measurements offer a reasonable alternative to rectal temperature measurement in afebrile horses
    Zobrist, Chelsea N.
    Bishop, Rebecca C.
    McCoy, Annette M.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2024, 262 (06): : 791 - 797
  • [7] Comparison of Body Temperature Values Measured With Noncontact Forehead Thermometer and Tympanic Thermometer in Adult Individuals
    Dogan, Sevgi
    Avsar, Gulcin
    JOURNAL OF NURSING MEASUREMENT, 2024, 32 (04) : 504 - 514
  • [8] Subjective assessment of fever by parents: Comparison with measurement by noncontact tympanic thermometer and calibrated rectal glass mercury thermometer
    Hooker, EA
    Smith, SW
    Miles, T
    King, L
    ANNALS OF EMERGENCY MEDICINE, 1996, 28 (03) : 313 - 317
  • [9] Comparison of Noncontact Forehead Infrared Thermometer with Digital Axillary Thermometer in Newborns in Low- and Middle-income Countries
    Das, Sreetama
    Pal, Somnath
    Ghosh, Moumita
    JOURNAL OF CLINICAL NEONATOLOGY, 2025, 14 (01) : 1 - 8
  • [10] A Comparative Study of Non-contact Infrared and Digital Rectal Thermometer Measurements of Body Temperature in the Horse
    Ramey, David
    Bachmann, Kristin
    Lee, Martin L.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2011, 31 (04) : 191 - 193