Noncontact infrared thermometer measurements offer a reasonable alternative to rectal temperature measurement in afebrile horses

被引:0
|
作者
Zobrist, Chelsea N. [1 ]
Bishop, Rebecca C. [1 ]
McCoy, Annette M. [1 ]
机构
[1] Univ Illinois, Coll Vet Med, Dept Vet Clin Med, Urbana, IL 61801 USA
关键词
equine; physical examination; safety; infrared thermometer; reference range; AXILLARY TEMPERATURE; BODY-TEMPERATURE; DOGS;
D O I
10.2460/javma.23.12.0714
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To assess the repeatability of infrared thermometer temperature readings and evaluate the correlation between digital rectal temperature and infrared thermometer temperatures taken at different locations in healthy afebrile horses. ANIMALS 101 afebrile horses >= 1 year old. METHODS Digital rectal temperatures and infrared temperatures from the eye, gingiva, neck, axilla, and perineum were obtained in a climate-controlled environment and at 2 outdoor ambient temperatures (study period, November 1, 2021, to April 30, 2023). RESULTS Infrared temperature measurements were well tolerated by horses, including those resistant to rectal temperature. There was significant correlation between rectal temperature and infrared temperature taken at the perineum (R R = 0.57; P < .001) and eye (R R = 0.37; P < .001). Infrared temperature measurements were highly repeatable, allowing for calculation of reference ranges for the perineum (36.0 to 37.8 degrees C) and eye (35.7 to 37.1 degrees C) in climate-controlled conditions. There was increased variance in outside temperatures compared to climate-controlled conditions for the eye (P P = .002), gingiva (P P = .047), and perineum (P P = .005). CLINICAL RELEVANCE While infrared thermometer temperatures were not numerically the same as rectal temperature using a digital thermometer, measurements at the perineum and eye were correlated with rectal temperature readings. Further, the repeatability of infrared readings allows for computation of reference ranges that make the infrared thermometer a viable alternative for the practicing veterinarian when obtaining a temperature in uncooperative horses. The infrared thermometer was reliable outdoors for the eye, but not the perineum. Additional validation of infrared temperature reference ranges in febrile horses and warmer ambient temperatures is warranted.
引用
收藏
页码:791 / 797
页数:7
相关论文
共 50 条
  • [1] Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer
    Kreissl, Hannah
    Neiger, Reto
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2015, 25 (03) : 372 - 378
  • [2] Variability in the measurement of corneal temperature using a noncontact infrared thermometer
    Koçak, I
    Orgül, S
    Flammer, J
    [J]. OPHTHALMOLOGICA, 1999, 213 (06) : 345 - 349
  • [3] A noninvasive method of temperature measurement using a noncontact handheld infrared thermometer fails to correlate with rectal temperature in dogs and cats
    Barton, James C.
    Didier, Martine D.
    Silvestrini, Paolo
    German, Alexander J.
    Ferriani, Riccardo
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2022, 260 (07): : 752 - 757
  • [4] An analysis of the effect of thermometer type and make on rectal temperature measurements of cattle, horses and sheep
    Hine, L.
    Laven, R. A.
    Sahu, S. K.
    [J]. NEW ZEALAND VETERINARY JOURNAL, 2015, 63 (03) : 171 - 173
  • [5] COMPARISON OF TEMPERATURE-MEASUREMENTS BY AN AURAL INFRARED THERMOMETER WITH MEASUREMENTS BY TRADITIONAL RECTAL AND AXILLARY TECHNIQUES
    YETMAN, RJ
    COODY, DK
    WEST, MS
    MONTGOMERY, D
    BROWN, M
    [J]. JOURNAL OF PEDIATRICS, 1993, 122 (05): : 769 - 773
  • [6] Clinical Accuracy of Tympanic Thermometer and Noncontact Infrared Skin Thermometer in Pediatric Practice An Alternative for Axillary Digital Thermometer
    Apa, Hursit
    Gozmen, Salih
    Bayram, Nuri
    Catikoglu, Asli
    Devrim, Fatma
    Karaarslan, Utku
    Gunay, Ilker
    Unal, Nurettin
    Devrim, Ilker
    [J]. PEDIATRIC EMERGENCY CARE, 2013, 29 (09) : 992 - 997
  • [7] Estimation of contact tympanic membrane temperature with a noncontact infrared thermometer
    Temdrup, TE
    Crofton, DJ
    Mortelliti, AJ
    Kelley, R
    Rajk, J
    [J]. ANNALS OF EMERGENCY MEDICINE, 1997, 30 (02) : 171 - 175
  • [8] Validation of rectal temperature measurements in horses
    Witte, T. S.
    Suthar, V.
    Heuwieser, W.
    [J]. REPRODUCTION IN DOMESTIC ANIMALS, 2012, 47 : 56 - 56
  • [9] Subjective assessment of fever by parents: Comparison with measurement by noncontact tympanic thermometer and calibrated rectal glass mercury thermometer
    Hooker, EA
    Smith, SW
    Miles, T
    King, L
    [J]. ANNALS OF EMERGENCY MEDICINE, 1996, 28 (03) : 313 - 317
  • [10] Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses
    Easterwood, Leslie
    Cohen, Noah D.
    [J]. JOURNAL OF EQUINE VETERINARY SCIENCE, 2023, 123