Noncontact infrared thermometer measurements offer a reasonable alternative to rectal temperature measurement in afebrile horses

被引:0
|
作者
Zobrist, Chelsea N. [1 ]
Bishop, Rebecca C. [1 ]
McCoy, Annette M. [1 ]
机构
[1] Univ Illinois, Coll Vet Med, Dept Vet Clin Med, Urbana, IL 61801 USA
关键词
equine; physical examination; safety; infrared thermometer; reference range; AXILLARY TEMPERATURE; BODY-TEMPERATURE; DOGS;
D O I
10.2460/javma.23.12.0714
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To assess the repeatability of infrared thermometer temperature readings and evaluate the correlation between digital rectal temperature and infrared thermometer temperatures taken at different locations in healthy afebrile horses. ANIMALS 101 afebrile horses >= 1 year old. METHODS Digital rectal temperatures and infrared temperatures from the eye, gingiva, neck, axilla, and perineum were obtained in a climate-controlled environment and at 2 outdoor ambient temperatures (study period, November 1, 2021, to April 30, 2023). RESULTS Infrared temperature measurements were well tolerated by horses, including those resistant to rectal temperature. There was significant correlation between rectal temperature and infrared temperature taken at the perineum (R R = 0.57; P < .001) and eye (R R = 0.37; P < .001). Infrared temperature measurements were highly repeatable, allowing for calculation of reference ranges for the perineum (36.0 to 37.8 degrees C) and eye (35.7 to 37.1 degrees C) in climate-controlled conditions. There was increased variance in outside temperatures compared to climate-controlled conditions for the eye (P P = .002), gingiva (P P = .047), and perineum (P P = .005). CLINICAL RELEVANCE While infrared thermometer temperatures were not numerically the same as rectal temperature using a digital thermometer, measurements at the perineum and eye were correlated with rectal temperature readings. Further, the repeatability of infrared readings allows for computation of reference ranges that make the infrared thermometer a viable alternative for the practicing veterinarian when obtaining a temperature in uncooperative horses. The infrared thermometer was reliable outdoors for the eye, but not the perineum. Additional validation of infrared temperature reference ranges in febrile horses and warmer ambient temperatures is warranted.
引用
收藏
页码:791 / 797
页数:7
相关论文
共 50 条
  • [41] A hollow waveguide infrared thermometer for polymer temperature measurement during injection moulding
    Bendaka, A
    Cole, K
    Lamontagne, M
    Simard, Y
    [J]. JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2003, 5 (05): : 464 - 470
  • [42] High-Precision Measurement of Sea Surface Temperature with Integrated Infrared Thermometer
    Zhang, Kailin
    Wang, Xinyu
    [J]. SENSORS, 2022, 22 (05)
  • [43] Estimating rectal temperature in exercising horses in a competition environment using infrared thermal imaging
    Marlin, D. J.
    Reynolds, H.
    Mukai, K.
    Neil, K.
    Akerstrom, G.
    [J]. COMPARATIVE EXERCISE PHYSIOLOGY, 2024, 20 (01) : 45 - 53
  • [44] Tunable diode laser-based two-line thermometry: a noncontact thermometer for active body temperature measurement
    Duan, Kun
    Ma, Liuhao
    Yi, Yong
    Ren, Wei
    [J]. APPLIED OPTICS, 2021, 60 (23) : 7036 - 7042
  • [45] Temperature monitoring in the auditory canal: Comparison of an infrared thermometer with conventional temperature sounds and assessment of clinical influencing factors on infrared measurement.
    Rohrberg, M
    Fritz, U
    Weyland, W
    Braun, U
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (07): : 409 - 413
  • [46] Estimating variation in surface emissivities of intertidal macroalgae using an infrared thermometer and the effects on temperature measurements
    Kathryn L. Van Alstyne
    Theresa K. Olson
    [J]. Marine Biology, 2014, 161 : 1409 - 1418
  • [47] Estimating variation in surface emissivities of intertidal macroalgae using an infrared thermometer and the effects on temperature measurements
    Van Alstyne, Kathryn L.
    Olson, Theresa K.
    [J]. MARINE BIOLOGY, 2014, 161 (06) : 1409 - 1418
  • [48] The use of thermometer protective sheets provides reliable measurement of rectal temperature: a prospective study in 500 dogs
    Jolivet, F.
    Pic, M.
    Rishniw, M.
    Concordet, D.
    Dossin, O.
    [J]. JOURNAL OF SMALL ANIMAL PRACTICE, 2020, 61 (04) : 216 - 223
  • [49] Miniature Uncooled and Unchopped Fiber Optic Infrared Thermometer for Application to Cutting Tool Temperature Measurement
    Heeley, Andrew D.
    Hobbs, Matthew J.
    Laalej, Hatim
    Willmott, Jon R.
    [J]. SENSORS, 2018, 18 (10)
  • [50] On-line Measurement of Fiber Temperature along Spinning Line Using Monochromatic Infrared Thermometer
    Wen, Xin
    Yang, Shenglin
    Li, Guang
    [J]. ADVANCED TECHNOLOGIES IN MANUFACTURING, ENGINEERING AND MATERIALS, PTS 1-3, 2013, 774-776 : 1538 - +