Comparison of a non-contact infrared thermometer with a rectal digital thermometer for use in ewes

被引:5
|
作者
Katsoulos, P. D. [1 ]
Athanasiou, L. V. [2 ]
Karatzia, M. A. [1 ]
Valasi, I. [3 ]
Boscos, C. [1 ]
Karatzias, H. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Clin Farm Anim, Fac Hlth Sci, Sch Vet Med, 11 St Voutyra, Thessaloniki, Greece
[2] Univ Thessaly, Sch Hlth Sci, Med Clin, Fac Vet Med, Kardhitsa, Greece
[3] Univ Thessaly, Sch Hlth Sci, Fac Vet Med, Physiol Lab, Kardhitsa, Greece
关键词
Non-contact; Infrared; Thermometer; Sheep; Rectal temperature; Cornea; Inguinal area; LINEAR-REGRESSION PROCEDURES; BODY-TEMPERATURE; CLINICAL-CHEMISTRY; SKIN TEMPERATURE; DOGS; SHEEP;
D O I
10.1016/j.smallrumres.2016.09.004
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The aim of this study was to assess the accuracy of measuring body temperature in sheep using a non contact infrared thermometer on the inguinal area and the eye cornea in comparison with a rectal digital thermometer. The trial for the first comparison was conducted in the milking parlor in 52 ewes in full lactation and 15 dry ewes and for the second one in 51 ewes. The body temperature measured with the noncontact infrared thermometer in the inguinal area, although significantly lower, was strongly linearly correlated with that of the rectal digital one in both ewes in full lactation and dry ewes. In lactating ewes, besides the high precision, the highest accuracy was also recorded and the plotted differences were within clinically insignificant levels. The corneal temperatures were highly correlated but were significantly lower compared to the rectal ones. Due to these differences the cut-off point of 37.9 degrees C was estimated to be adopted for the detection of the hyperthermic animals when noncontact infrared thermometers are applied to the eye cornea for the measurement of body temperature. In conclusion the inguinal area of the dry ewes and the eye cornea cannot be recommended as appropriate sites for body temperature measurement because the temperatures recorded are biased by external factors. The noncontact infrared thermometer evaluated is sufficiently accurate for the measurement of body temperature in sheep only when applied in the inguinal area of sheep in full lactation. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:84 / 88
页数:5
相关论文
共 50 条
  • [1] Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer
    Bayhan, Cihangul
    Ozsurekci, Yasemin
    Tekcam, Necmiye
    Guloglu, Ayse
    Ehliz, Gulten
    Ceyhan, Mehmet
    Kara, Ates
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (02): : 52 - 55
  • [2] Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer
    Ilce, Arzu
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (04): : 200 - 200
  • [3] Agreement of Temperatures Measured Using a Non-Contact Infrared Thermometer With a Rectal Digital Thermometer in Horses
    Easterwood, Leslie
    Cohen, Noah D.
    [J]. JOURNAL OF EQUINE VETERINARY SCIENCE, 2023, 123
  • [4] DESIGN OF A NON-CONTACT INFRARED THERMOMETER
    Long, Guangli
    [J]. INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2016, 9 (02): : 1110 - 1129
  • [5] A Comparative Study of Non-contact Infrared and Digital Rectal Thermometer Measurements of Body Temperature in the Horse
    Ramey, David
    Bachmann, Kristin
    Lee, Martin L.
    [J]. JOURNAL OF EQUINE VETERINARY SCIENCE, 2011, 31 (04) : 191 - 193
  • [6] Non-contact thermometer
    不详
    [J]. CHIMICA OGGI-CHEMISTRY TODAY, 1997, 15 (6-7) : 83 - 83
  • [7] Performance of a non-contact infrared thermometer in healthy newborns
    Sollai, Sara
    Dani, Carlo
    Berti, Elettra
    Fancelli, Claudia
    Galli, Luisa
    de Martino, Maurizio
    Chiappini, Elena
    [J]. BMJ OPEN, 2016, 6 (03):
  • [8] Donor Temperature Screening with a Non-Contact Infrared Thermometer
    Navarro, Marie
    Molfese, Paul M.
    Rioveros, Jowin
    Villasin, Emylee
    Godoy, Jessica
    Ziman, Alyssa
    McGonigle, Andrea M.
    Mei, Zhen Wei
    Ward, Dawn C.
    [J]. TRANSFUSION, 2022, 62 : 151A - 151A
  • [9] Comparison of body temperature in cats using a veterinary infrared thermometer and a digital rectal thermometer
    Kunkle, GA
    Nicklin, CF
    Sullivan-Tamboe, DL
    [J]. JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2004, 40 (01) : 42 - 46
  • [10] Non contact infrared thermometer
    不详
    [J]. AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 1999, 71 (03): : 301 - 301