Comparison of a non-contact infrared thermometer with a rectal digital thermometer for use in ewes

被引:5
|
作者
Katsoulos, P. D. [1 ]
Athanasiou, L. V. [2 ]
Karatzia, M. A. [1 ]
Valasi, I. [3 ]
Boscos, C. [1 ]
Karatzias, H. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Clin Farm Anim, Fac Hlth Sci, Sch Vet Med, 11 St Voutyra, Thessaloniki, Greece
[2] Univ Thessaly, Sch Hlth Sci, Med Clin, Fac Vet Med, Kardhitsa, Greece
[3] Univ Thessaly, Sch Hlth Sci, Fac Vet Med, Physiol Lab, Kardhitsa, Greece
关键词
Non-contact; Infrared; Thermometer; Sheep; Rectal temperature; Cornea; Inguinal area; LINEAR-REGRESSION PROCEDURES; BODY-TEMPERATURE; CLINICAL-CHEMISTRY; SKIN TEMPERATURE; DOGS; SHEEP;
D O I
10.1016/j.smallrumres.2016.09.004
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The aim of this study was to assess the accuracy of measuring body temperature in sheep using a non contact infrared thermometer on the inguinal area and the eye cornea in comparison with a rectal digital thermometer. The trial for the first comparison was conducted in the milking parlor in 52 ewes in full lactation and 15 dry ewes and for the second one in 51 ewes. The body temperature measured with the noncontact infrared thermometer in the inguinal area, although significantly lower, was strongly linearly correlated with that of the rectal digital one in both ewes in full lactation and dry ewes. In lactating ewes, besides the high precision, the highest accuracy was also recorded and the plotted differences were within clinically insignificant levels. The corneal temperatures were highly correlated but were significantly lower compared to the rectal ones. Due to these differences the cut-off point of 37.9 degrees C was estimated to be adopted for the detection of the hyperthermic animals when noncontact infrared thermometers are applied to the eye cornea for the measurement of body temperature. In conclusion the inguinal area of the dry ewes and the eye cornea cannot be recommended as appropriate sites for body temperature measurement because the temperatures recorded are biased by external factors. The noncontact infrared thermometer evaluated is sufficiently accurate for the measurement of body temperature in sheep only when applied in the inguinal area of sheep in full lactation. (C) 2016 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:84 / 88
页数:5
相关论文
共 50 条
  • [41] Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer
    Cugmas, Blaz
    Susteric, Primoz
    Gorenjec, Nina Ruzic
    Plavec, Tanja
    VETERINARY AND ANIMAL SCIENCE, 2020, 9
  • [42] A MINIATURE CONTACT THERMOMETER FOR STUDENT USE
    BRUNO, TJ
    SHEPHERD, JG
    JOURNAL OF CHEMICAL EDUCATION, 1986, 63 (05) : 452 - 452
  • [43] Development and test of a long wavelength infrared radiation thermometer for non-contact temperature measurements in gas turbines during operation
    Manara, Jochen
    Stark, Thomas
    Zipf, Matthias
    Arduini, Mariacarla
    Ebert, Hans-Peter
    Hartmann, Juergen
    Tutschke, Andreas
    Hallam, Andrew
    Hanspal, Jagdevinder
    Langley, Mark
    TM-TECHNISCHES MESSEN, 2018, 85 (01) : 28 - 39
  • [44] Application of a Multichannel Radiation Thermometer for Increase in Adequacy of Non-contact Temperature Measurement Results
    Chernysheva, Nadezda S.
    Ionov, Anton B.
    2015 16TH INTERNATIONAL CONFERENCE OF YOUNG SPECIALISTS ON MICRO/NANOTECHNOLOGIES AND ELECTRON DEVICES, 2015, : 334 - 336
  • [45] USE OF THE PORTABLE INFRARED THERMOMETER IN EQUINE PRACTICE
    PALMER, SE
    PROCEEDINGS OF THE ANNUAL CONVENTION OF THE AMERICAN ASSOCIATION OF EQUINE PRACTITIONERS, 1980, 26 (NOV-): : 327 - 334
  • [46] IMPROVED FIELD USE OF A SIMPLE INFRARED THERMOMETER
    STIGTER, CJ
    MAKONDA, MM
    JIWAJI, NT
    ACTA BOTANICA NEERLANDICA, 1982, 31 (5-6): : 379 - 389
  • [47] MEASUREMENT OF PRODUCT TEMPERATURE BY USE OF AN INFRARED THERMOMETER
    MAHNKE, CW
    SOUCHECK, JA
    INSALATA, NF
    APPLIED MICROBIOLOGY, 1973, 26 (04) : 646 - 647
  • [48] An open-source non-contact thermometer using low-cost electronic components
    Mnati, Mohannad Jabbar
    Chisab, Raad Farhood
    Al-Rawi, Azhar M.
    Ali, Adnan Hussein
    Van den Bossche, Alex
    HARDWAREX, 2021, 9
  • [49] Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures
    Rotello, LC
    Crawford, L
    Terndrup, TE
    CRITICAL CARE MEDICINE, 1996, 24 (09) : 1501 - 1506
  • [50] COMPARISON OF TEMPERATURE-MEASUREMENTS BY AN AURAL INFRARED THERMOMETER WITH MEASUREMENTS BY TRADITIONAL RECTAL AND AXILLARY TECHNIQUES
    YETMAN, RJ
    COODY, DK
    WEST, MS
    MONTGOMERY, D
    BROWN, M
    JOURNAL OF PEDIATRICS, 1993, 122 (05): : 769 - 773