Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer

被引:18
|
作者
Cugmas, Blaz [1 ]
Susteric, Primoz [2 ]
Gorenjec, Nina Ruzic [3 ]
Plavec, Tanja [4 ,5 ]
机构
[1] Univ Latvia, Inst Atom Phys & Spect, Biophoton Lab, 19 Raina Blvd, LV-1586 Riga, Latvia
[2] Primavet Vet Clin, 38 Ptujska Rd, SI-2327 Race, Slovenia
[3] Univ Ljubljana, Fac Med, Inst Biostat & Med Informat, 2 Vrassov Sq, SI-1000 Ljubljana, Slovenia
[4] Univ Ljubljana, Vet Fac, Small Anim Clin, 60 Gerbiceva Str, SI-1000 Ljubljana, Slovenia
[5] Small Anim Vet Hosp Hofheim, 7 Katharina Kemmpler St, DE-65719 Hofheim, Germany
来源
基金
欧盟地平线“2020”;
关键词
Body surface temperature; Dog; Infrared thermometer; Health status; Rectal temperature; TYMPANIC MEMBRANE; AURICULAR TEMPERATURE; DAILY RHYTHMICITY; PULMONARY-ARTERY; AXILLARY; ACCURACY; STRESS; CORE;
D O I
10.1016/j.vas.2020.100120
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Because dogs tolerate conventional rectal temperature measurements poorly, a calibrated infrared thermometer was tested for assessing canine body surface temperature. Body surface temperature of 204 dogs was estimated on various sites (digit, snout, axilla, eye, gum, inguinal region, and anal verge). Having rectal temperature as the gold standard, temperature difference, Spearman's correlation coefficient, hyperthermia and hypothermia detection sensitivity and specificity, and stress response score was calculated for each measurement site. Although the canine body surface temperature was considerably lower than the rectal temperature, there was a moderate correlation between both temperatures. Spearman's coefficients were 0.60 (p < 0.001) for the inguinal region with a single operator and 0.50 (p < 0.001) for the gum with multiple operators. Measurement site on the gum additionally guaranteed hyperthermia detection sensitivity and specificity up to 90.0% (95% CI: [66.7 100]) and 78.6% (95% CI: [71.6 85.2]), respectively. Measurements with the infrared thermometer provoked a statistically significant lower stress response (mean stress scores between 1.89 and 2.48/5) compared to the contact rectal measurements (stress score of 3.06/5). To conclude, the correct body surface temperature measurement should include a calibrated thermometer, reliable sampling, and the control of external factors such as ambient temperature influence. The transformation of body surface temperature to the recognized rectal temperature interval allows more straightforward data interpretation. The gum temperature exhibited the best clinical potential since the differences to rectal temperatures were below 1 degrees C, and hyperthermia was detected with the sensitivity of up to 90%.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer
    Kreissl, Hannah
    Neiger, Reto
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2015, 25 (03) : 372 - 378
  • [2] Comparison of body temperature in cats using a veterinary infrared thermometer and a digital rectal thermometer
    Kunkle, GA
    Nicklin, CF
    Sullivan-Tamboe, DL
    [J]. JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2004, 40 (01) : 42 - 46
  • [3] Comparison between tympanic and anal temperature with a clinical infrared ray thermometer in dogs
    Wiedemann, G. G. S.
    Scalon, M. C.
    Paludo, G.
    Silva, I. O.
    Boere, V.
    [J]. ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2006, 58 (04) : 503 - 505
  • [4] Correlation between superficial body temperatures measured with an infrared thermometer and rectal temperature in alpacas
    Vilela, Jorge L.
    Goycochea, Gianella
    Serna, Allison
    Veramendi, Frank
    Ascue, Jorge
    Callan, Milagros
    Jauregui, Andrea
    Miranda, Almendra
    Montalvo, Pamela
    Sandoval, Aranza
    Solis, Sebastian
    [J]. JOURNAL OF ANIMAL SCIENCE, 2020, 98 : 214 - 214
  • [5] Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs
    Sousa, Marlos G.
    Carareto, Roberta
    Pereira-Junior, Valdo A.
    Aquino, Monally C. C.
    [J]. CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2011, 52 (04): : 403 - 406
  • [6] Comparison of body temperatures of goats, horses, and sheep measured with a tympanic infrared thermometer, an implantable microchip transponder, and a rectal thermometer
    Goodwin, SD
    [J]. CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 1998, 37 (03): : 51 - 55
  • [7] Comparison of an infrared ear thermometer to rectal thermometers in cats
    Michaud, AJ
    [J]. FELINE PRACTICE, 1996, 24 (06): : 25 - 30
  • [8] Comparison between rectal and infrared skin temperature in the newborn
    De Curtis, Mario
    Calzolari, Flaminia
    Marclano, Alessandra
    Cardilli, Viviana
    Barba, Glanvincenzo
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2008, 93 (01): : F55 - F57
  • [9] A noninvasive method of temperature measurement using a noncontact handheld infrared thermometer fails to correlate with rectal temperature in dogs and cats
    Barton, James C.
    Didier, Martine D.
    Silvestrini, Paolo
    German, Alexander J.
    Ferriani, Riccardo
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2022, 260 (07): : 752 - 757
  • [10] Correlation and agreement between infrared thermography and a thermometer for equine body temperature measurements
    Lampang, Kannika Na
    Isawirodom, Ashannut
    Rungsri, Porrakote
    [J]. VETERINARY WORLD, 2023, 16 (12) : 2464 - 2470