Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer

被引:19
|
作者
Kreissl, Hannah [1 ]
Neiger, Reto [1 ]
机构
[1] Univ Giessen, Small Anim Clin, Dept Clin Studies, Giessen, Germany
关键词
canine; fever; monitoring; thermoregulation; MICROCHIP TRANSPONDER; TYMPANIC TEMPERATURE; CORE TEMPERATURE; OTITIS-EXTERNA; CHILDREN; AGREEMENT; ARTERY; CATS; SKIN; ACCURACY;
D O I
10.1111/vec.12302
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo assess the accuracy of obtaining body temperatures in dogs with a noncontact infrared thermometer (NCIT) on the cornea compared with a rectal digital thermometer (RDT). DesignProspective single center study. SettingUniversity teaching hospital. AnimalsThree hundred dogs presented with low, normal, or high body temperatures. InterventionsThree body temperature readings were measured by an RDT and by an NCIT on the cornea of the left eye by 2 investigators (experienced and inexperienced). Results obtained by the 2 methods were compared. Measurements and Main ResultsMedian body temperature measured by the experienced investigator with the RDT and the NCIT were 38.3 degrees C (range 35.5 degrees C-41.1 degrees C; 95% CI: 38.2-38.4 degrees C) and 37.7 degrees C (35.9 degrees C-40.1 degrees C; 95% CI: 37.7 degrees C-37.9 degrees C), respectively. Measurement of RDT as well as of NCIT correlated well between both investigators (r(RDT) = 0.94; r(NCIT) = 0.82; respectively, P < 0.001 for both methods). Mean RDT and NCIT-temperature correlated poorly (r = 0.43; P < 0.001) when taken by the experienced investigator and even less by the nonexperienced investigator (r = 0.38; P < 0.001). Repeatability of the NCIT revealed an unsatisfactory value (0.24 degrees C) compared to RDT measurement (0.12 degrees C). Agreement between both devices in measuring low, normal, and high values, calculated by Cohens-Kappa, was unsatisfactory (k = 0.201; P < 0.001). Calculating the receiver operating characteristic curve to determine the best threshold for fever (defined as RDT temperature >39.0 degrees C) showed an area under the curve of 0.76. Mean discomfort score was significantly lower using NCIT compared to RDT measurement (P < 0.001). ConclusionsThere was poor agreement between body temperatures obtained by RDT and NCIT. The corneal NCIT measurement tends to underrecognize hypothermic and hyperthermic conditions. Although the use of the NCIT yields faster results and is significantly more comfortable for the dog than the RDT measurement, it cannot be recommended in dogs at this time.
引用
收藏
页码:372 / 378
页数:7
相关论文
共 30 条
  • [21] Temperature monitoring in the auditory canal: Comparison of an infrared thermometer with conventional temperature sounds and assessment of clinical influencing factors on infrared measurement.
    Rohrberg, M
    Fritz, U
    Weyland, W
    Braun, U
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (07): : 409 - 413
  • [22] Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
    Kawakami, Yu
    Sielski, Rachel
    Kawakami, Toshiaki
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (139):
  • [23] Comparison of infrared tympanic, non-contact infrared skin, and axillary thermometer to rectal temperature measurements in a pediatric emergency observation unit
    Berksoy, Emel Atas
    Anil, Murat
    Bicilioglu, Yuksel
    Gokalp, Gamze
    Bal, Alkan
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 567 - 573
  • [24] Comparison of rectal temperature measured by digital vs. mercury glass thermometer in infants under two months old
    Jones, HL
    Kleber, CB
    Eckert, GJ
    Mahon, BE
    [J]. CLINICAL PEDIATRICS, 2003, 42 (04) : 357 - 359
  • [25] Comparison of rectal temperature measured by digital vs. mercury glass thermometer in infants under two months old
    Jones, HL
    Kleber, CB
    Eckert, GJ
    Mahon, BE
    [J]. PEDIATRIC RESEARCH, 2002, 51 (04) : 149A - 150A
  • [26] Body temperature measurement in anesthetized dogs - comparison of nasal, axillary, rectal and esophageal temperature
    Ward, Rob
    Mcmillan, Matt
    Gittel, Claudia
    [J]. TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2023, 51 (03): : 161 - 167
  • [27] A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting
    Ajcevic, Milos
    Stella, Alex Buoite
    Furlanis, Giovanni
    Caruso, Paola
    Naccarato, Marcello
    Accardo, Agostino
    Manganotti, Paolo
    [J]. SENSORS, 2022, 22 (13)
  • [28] RELATIONSHIP BETWEEN RECTAL TEMPERATURE MEASURED WITH A CONVENTIONAL THERMOMETER AND THE TEMPERATURE OF SEVERAL BODY REGIONS MEASURED BY INFRARED THERMOGRAPHY IN FATTENING RABBITS. INFLUENCE OF DIFFERENT ENVIRONMENTAL FACTORS
    Jaen-Tellez, J. A.
    Bartolome, E.
    Sanchez-Guerrero, M. J.
    Valera, M.
    Gonzalez-Redondo, P.
    [J]. WORLD RABBIT SCIENCE, 2021, 29 (04) : 263 - 273
  • [29] Comparison of body temperature in donkeys using rectal digital, infrared, and mercury-in-glass thermometers during the hot-dry season in a tropical savannah
    Friday Ocheja Zakari
    Joseph Olusegun Ayo
    [J]. International Journal of Biometeorology, 2021, 65 : 1053 - 1067
  • [30] Comparison of body temperature in donkeys using rectal digital, infrared, and mercury-in-glass thermometers during the hot-dry season in a tropical savannah
    Zakari, Friday Ocheja
    Ayo, Joseph Olusegun