A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting

被引:15
|
作者
Ajcevic, Milos [1 ,2 ]
Stella, Alex Buoite [1 ]
Furlanis, Giovanni [1 ]
Caruso, Paola [1 ]
Naccarato, Marcello [1 ]
Accardo, Agostino [2 ]
Manganotti, Paolo [1 ]
机构
[1] Univ Trieste, Cattinara Univ Hosp ASUGI, Dept Med Surg & Hlth Sci, Clin Unit Neurol, Str Fiume, I-44734149 Trieste, Italy
[2] Univ Trieste, Dept Engn & Architecture, Via A Valerio, I-1034127 Trieste, Italy
关键词
continuous non-invasive temperature monitoring; core temperature; clinical thermometry; acute stroke; heat flux; wearable device; CRITICALLY-ILL PATIENTS; TEMPORAL-ARTERY; FEVER; CARE; ACCURACY; BLADDER; ESOPHAGEAL; AXILLARY; SENSOR; ADULT;
D O I
10.3390/s22134760
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is a growing research interest in wireless non-invasive solutions for core temperature estimation and their application in clinical settings. This study aimed to investigate the use of a novel wireless non-invasive heat flux-based thermometer in acute stroke patients admitted to a stroke unit and compare the measurements with the currently used infrared (IR) tympanic temperature readings. The study encompassed 30 acute ischemic stroke patients who underwent continuous measurement (Tcore) with the novel wearable non-invasive CORE device. Paired measurements of Tcore and tympanic temperature (Ttym) by using a standard IR-device were performed 3-5 times/day, yielding a total of 305 measurements. The predicted core temperatures (Tcore) were significantly correlated with Ttym (r = 0.89, p < 0.001). The comparison of the Tcore and Ttym measurements by Bland-Altman analysis showed a good agreement between them, with a low mean difference of 0.11 +/- 0.34 degrees C, and no proportional bias was observed (B = -0.003, p = 0.923). The Tcore measurements correctly predicted the presence or absence of Ttym hyperthermia or fever in 94.1% and 97.4% of cases, respectively. Temperature monitoring with a novel wireless non-invasive heat flux-based thermometer could be a reliable alternative to the Ttym method for assessing core temperature in acute ischemic stroke patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Investigation of Non-invasive Continuous Body Temperature Measurements in a Clinical Setting Using an Adhesive Axillary Thermometer (SteadyTemp®)
    Boyer, Johannes
    Eckmann, Jakob
    Strohmayer, Karl
    Koele, Werner
    Federspiel, Moritz
    Schenk, Michael
    Weiss, Gregor
    Krause, Robert
    FRONTIERS IN DIGITAL HEALTH, 2021, 3
  • [2] Non-invasive and wearable thermometer for continuous monitoring of core body temperature under various convective conditions
    Matsunaga, D.
    Tanaka, Y.
    Seyama, M.
    Nagashima, K.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4377 - 4380
  • [3] Non-invasive Core Body Temperature Sensor for Continuous Monitoring
    Anuar, Hamizah
    Leow, Pei Ling
    2019 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SN), 2019, : 61 - 64
  • [4] Clinical accuracy of infrared temperature measurement devices: a comparison against non-invasive core-body temperature
    Holder, Thomas
    Hooper, Frances Sophie Woodley
    Yates, David
    Tse, Zion
    Patil, Samadhan
    Moussa, Ahmed
    Batten, Lucy
    Radhakrishnan, Vignesh
    Allison, Mark
    Hewitt, Catherine
    Keding, Ada
    Forshaw, Greg
    Jayagopal, Vijay
    CLINICAL MEDICINE, 2023, 23 (02) : 157 - 163
  • [5] Comparison of tympanic temperature readings with axillary thermometer in the OPD setting
    Malik, Munir
    Rabbani, Mohammad Zafar
    Amir, Mohammed
    Afzal, Uzma
    Malik, Mohammad Umair
    RAWAL MEDICAL JOURNAL, 2009, 34 (02):
  • [6] Measuring core body temperature with a non-invasive sensor
    Mazgaoker, Savyon
    Ketko, Itay
    Yanovich, Ran
    Heled, Yuval
    Epstein, Yoram
    JOURNAL OF THERMAL BIOLOGY, 2017, 66 : 17 - 20
  • [7] Toward Non-Invasive Core Body Temperature Sensing
    Guido, Katrina
    Bringer, Alexandra
    Kiourti, Asimina
    2021 UNITED STATES NATIONAL COMMITTEE OF URSI NATIONAL RADIO SCIENCE MEETING (USNC-URSI NRSM), 2021, : 164 - 165
  • [8] Continuous and non-invasive thermography of mouse skin accurately describes core body temperature patterns, but not absolute core temperature
    Vincent van der Vinne
    Carina A. Pothecary
    Sian L. Wilcox
    Laura E. McKillop
    Lindsay A. Benson
    Jenya Kolpakova
    Shu K. E. Tam
    Lukas B. Krone
    Angus S. Fisk
    Tatiana S. Wilson
    Tomoko Yamagata
    James Cantley
    Vladyslav V. Vyazovskiy
    Stuart N. Peirson
    Scientific Reports, 10
  • [9] Continuous and non-invasive thermography of mouse skin accurately describes core body temperature patterns, but not absolute core temperature
    van der Vinne, Vincent
    Pothecary, Carina A.
    Wilcox, Sian L.
    McKillop, Laura E.
    Benson, Lindsay A.
    Kolpakova, Jenya
    Tam, Shu K. E.
    Krone, Lukas B.
    Fisk, Angus S.
    Wilson, Tatiana S.
    Yamagata, Tomoko
    Cantley, James
    Vyazovskiy, Vladyslav V.
    Peirson, Stuart N.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] Tympanic Temperature Comparison with Oral Mercury Thermometer Readings in an OPD Setting
    Rabbani, Mohammad Zafar
    Amir, Mohammed
    Malik, Munir
    Mufti, Mazhar
    Bin Pervez, Mohammad
    Iftekhar, Sahar
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2010, 20 (01): : 33 - 36