Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit

被引:36
|
作者
Papaspyridakos, Panos [1 ,2 ]
Hirayama, Hiroshi [1 ]
Chen, Chun-Jung [3 ]
Ho, Chung-Han [4 ]
Chronopoulos, Vasilios [2 ,5 ]
Weber, Hans-Peter [1 ]
机构
[1] Tufts Univ, Sch Dent Med, Div Postgrad Prosthodont, 1 Kneeland St, Boston, MA 02111 USA
[2] Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[3] Chi Mei Med Ctr, Dept Dent, Tainan, Taiwan
[4] Chi Mei Med Ctr, Dept Med Res, Tainan, Taiwan
[5] Griffith Univ, Sch Dent & Oral Hlth, Dept Restorat Dent, Gold Coast, Qld, Australia
关键词
accuracy of fit; connection type; digital dentistry; edentulous; full-arch prostheses; implant impressions; EDENTULOUS PATIENTS; COMPLICATIONS; FRAMEWORKS; DENTISTRY; PASSIVITY; MISFIT;
D O I
10.1111/clr.12695
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs). Materials and Methods: An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant-and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used. Results: Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05). Conclusion: For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found.
引用
下载
收藏
页码:1099 / 1105
页数:7
相关论文
共 50 条
  • [1] Accuracy of Successive Casts for Full-Arch Fixed Prostheses
    Dounis, Kiki S.
    Dounis, Georgia
    Ditmyer, Marcia M.
    Ziebert, Gerald J.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (05) : 446 - 449
  • [2] Full-arch prostheses from translucent zirconia: Accuracy of fit
    Sachs, Caroline
    Groesser, Julian
    Stadelmann, Markus
    Schweiger, Josef
    Erdelt, Kurt
    Beuer, Florian
    DENTAL MATERIALS, 2014, 30 (08) : 817 - 823
  • [3] Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study
    Papaspyridakos, Panos
    Lal, Kunal
    White, George Shelby
    Weber, Hans-Peter
    Gallucci, German O.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1267 - 1272
  • [4] Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation
    Pesce, Paolo
    Pera, Francesco
    Setti, Paolo
    Menini, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 171 - 175
  • [5] The effect of framework fabrication technique on the fit accuracy of full arch screw retained implant supported prostheses
    AlRasheed, Fellwa
    AlWazzan, Khalid
    SAUDI DENTAL JOURNAL, 2022, 34 (04) : 288 - 297
  • [6] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [7] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    BMC ORAL HEALTH, 2020, 20 (01)
  • [8] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [9] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [10] Complications of Fixed Full-Arch Implant-Supported Metal-Ceramic Prostheses
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Brizuela-Velasco, Aritza
    Alvarez-Riesgo, Jose-Antonio
    Llorente-Pendas, Santiago
    Herrero-Climent, Mariano
    Alvarez-Arenal, Angel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 23