accuracy of fit;
connection type;
digital dentistry;
edentulous;
full-arch prostheses;
implant impressions;
EDENTULOUS PATIENTS;
COMPLICATIONS;
FRAMEWORKS;
DENTISTRY;
PASSIVITY;
MISFIT;
D O I:
10.1111/clr.12695
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Purpose: The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs). Materials and Methods: An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant-and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used. Results: Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05). Conclusion: For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found.
机构:
Harvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
Columbia Univ, Coll Dent Med, Div Prosthodont, New York, NY USAHarvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
Papaspyridakos, Panos
Lal, Kunal
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Coll Dent Med, Div Prosthodont, New York, NY USAHarvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
Lal, Kunal
White, George Shelby
论文数: 0引用数: 0
h-index: 0
机构:
Columbia Univ, Coll Dent Med, Div Prosthodont, New York, NY USAHarvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
White, George Shelby
Weber, Hans-Peter
论文数: 0引用数: 0
h-index: 0
机构:
Harvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA 02111 USAHarvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
Weber, Hans-Peter
Gallucci, German O.
论文数: 0引用数: 0
h-index: 0
机构:
Harvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USAHarvard Univ, Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
机构:
King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 60169, Riyadh 11545, Saudi ArabiaKing Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 60169, Riyadh 11545, Saudi Arabia
AlRasheed, Fellwa
AlWazzan, Khalid
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 60169, Riyadh 11545, Saudi ArabiaKing Saud Univ, Coll Dent, Dept Prosthet Dent Sci, POB 60169, Riyadh 11545, Saudi Arabia
机构:
Sechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, RussiaSechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, Russia
Mangano, Francesco Guido
Admakin, Oleg
论文数: 0引用数: 0
h-index: 0
机构:
Sechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, RussiaSechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, Russia
Admakin, Oleg
Bonacina, Matteo
论文数: 0引用数: 0
h-index: 0
机构:
Ars & Technol, Sotto Monte Giovanni 23, I-24039 Bergamo, ItalySechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, Russia
Bonacina, Matteo
Lerner, Henriette
论文数: 0引用数: 0
h-index: 0
机构:
Goethe Univ Frankfurt, Acad Teaching & Res Inst, D-60323 Frankfurt, GermanySechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, Russia
Lerner, Henriette
Rutkunas, Vygandas
论文数: 0引用数: 0
h-index: 0
机构:
Vilnius Univ, Fac Med, Inst Odontol, Dept Prosthodont, LT-01513 Vilnius, LithuaniaSechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, Russia
Rutkunas, Vygandas
Mangano, Carlo
论文数: 0引用数: 0
h-index: 0
机构:
Vita & Salute Univ San Raffaele, Dept Dent Sci, I-20132 Milan, ItalySechenov First State Med Univ, Dept Prevent & Communal Dent, Moscow 119992, Russia